MR View&GO - Breast MoCo & Subtraction

This job aid provides a workflow for performing manual Motion Correction (MoCo) and Subtraction for MR breast images on Numaris X software.

MR View&GO – Breast MoCo & Subtraction Job Aid syngo MR systems with Numaris X This job aid provides a workflow for performing manual Motion Correction (MoCo) and Subtraction for MR Breast images on Numaris X software. 1. In MR View&GO, the dynamic Breast series can be 4D n loaded into a segment as: 9:16:18 AM 8 IMA 1 FRM 48/124 a. 4D series scanned loads as a 4D collapsed series into the viewing segment. b. Dynamic series scanned separately loads each RH series into individual viewing segments. 2D SL 1.5 10cm FJ TR 5.1 SP F17.3 TE 2.4 FoV 360*360 p2 MAGN/M/NORM/DIS2D Zoom 0.74 2. Select all Dynamic series: a. If Series are individual line items, select each series with (ctrl + left click) and load them individually into the viewing segments. -or- b. If Series are stacked, highlight the series (left click) and load it into the viewing segments. c. Ctrl + left click to highlight the loaded dynamic series in the viewing segments. 3. In Favorite Tools, click [+] icon to open the Tools Gallery window. Favorite Tools X Tool Gallery Growing Visualizer Label Views 3D Print & Export Show in TimeCurve ADC & b- Composel Image 3D value Combine Sorting Snapshot Print Print Stack Print Export Export Export Image Image Layout Image Image Stack Save as Fit to Segment Fit to Acq. Size MR-Tools istanc Position Snapshot Print Stack Mosaic Position Position Position Position Compose Point Displa ... Displa ... Display All Displa ... Combine Line Displa ... - Save As non-DICOM Flip Save as Mosaic Subtracti ... JPG Horizontal Series non- Punch MR Calculation + × Subtracti ... Addition Multiplic ... Division Arithmetic Motion Mea Correction + Postprocessing 3 Show in TimeCurve Image Unrestricted | Published by Siemens Healthineers AG, 2025 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 03/04/2025 | QR700019081 Healthineers 4. In the Tools Gallery window, select the Motion Correction icon. Motion Lorrection 5. Motion Correction window opens. a. Settings default to MR Motion Correction Settings. b. Reference Volume, automatically set as the 1st Post Contrast Phase (i.e., default name entered). c. Input Volume automatically loads all Post Contrast Phases except the reference volume. d. Reference Volume, default name entered. e. Click OK, to accept and run Motion Correction. Motion Correction ? X Settings MR Motion Correction Setti. Config. Input Volumes t1_f13d_tra_dynaVIEWS_1+4.latest.Phase_01 t1_f13d_tra_dynaVIEWS_1+4.latest.Phase_03 t1_f13d_tra_dynaVIEWS_1+4.latest.Phase 04 t1_f13d_tra_dynaVIEWS_1+4.latest.Phase_05 Remove Reference Volume t1_f13d_tra_dynaVIEWS_1+4.latest.Phase_02 Result Series Name Results MoCoHiQ_t1_f13d_tra_dynaVIEWS_1+4 To OK Cancel Unrestricted | Published by Siemens Healthineers AG, 2025 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 03/04/2025 | QR700019081 Healthineers Page 2 of 5 6. Pull the newly created Motion Corrected [MoCoHiQ] Dynamic series results in the viewing : Results MoCoHiQ_t1_f13d_ segments. 10 ... : Phase_01 a. Ctrl + left click to highlight the MoCoHiQ and load into the viewing segments. 10 ... : Phase_02 10 ... Phase_03 10 ... : Phase_04 10 ... : Phase_05 7. In the Favorite Tools, select Subtraction. Subtracti ... 8. Create Subtraction Datagroup window opens. a. Settings, click drop-down and choose User Create Subtraction Datagroup ? x defined preset (e.g., MR Breast Subtraction). b. Minuend automatically loads all Subtraction Settings MR Breast Subtraction series. MR Subtraction Settings Minuend MR Breast Subtraction st. Phase 02 c. Subtrahend, automatically set to Pre-contrast t1_f13d_tra_dyn_spair_1+5.latest.Phase_03 t1_f13d_tra_dyn_spair_1+5.latest.Phase_04 t1_f13d_tra_dyn_spair_1+5.latest.Phase_05 series based on the contrast injection pause t1_f13d_tra_dyn_spair_1+5.latest.Phase_06 location while scanning all Post Contrast Phases. d. Use Constant, default [0] entered. Subtrahend t1_f13d_tra_dyn_spair_1+5. latest. Phase_01 e. Result Series Name, default name entered. Use Constant f. Click OK, to accept and run Subtraction. i. New results created are saved in the Series list. g. Click Save and Pause, to save results to Result Series Name Results Sub_P1_1_f13d_tra_dyn_spair_1+5 Patient Browser. OK Cancel  To create a User defined MR Breast Preset, see below. Unrestricted | Published by Siemens Healthineers AG, 2025 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 03/04/2025 | QR700019081 Healthineers Page 3 of 5 User defined Preset in Configuration Menu for Breast Subtraction: 1. Select the Configuration (Cogwheel) icon. Create Subtraction Datagroup ? X Settings MR Subtraction Settings Config . Minuend t1_f13d_tra_dyn_spair_1+5.latest. Phase_02 t1_f13d_tra_dyn_spair_1+5.latest.Phase_03 t1_f13d_tra_dyn_spair_1+5.latest.Phase_04 t1_f13d_tra_dyn_spair_1+5.latest.Phase_05 t1_f13d_tra_dyn_spair_1+5.latest.Phase_06 Subtrahend t1_f13d_tra_dyn_spair_1+5.latest.Phase_01 Use Constant Result Series Name Results Sub_P1_t1_f13d_tra_dyn_spair_1+5 OK Cancel 2. Subtraction Settings window (recommendations): a. Name of Settings: MR Breast Subtraction. Subtraction Settings b. Subtrahend = 1 (Pre) Phase. Settings c. Subtraction Mode = Absolute. w/ MR Subtraction Setti Name of Settings MR Breast Subtraction d. Use Constant = 0. MR Breast Subtraction Subtrahend Phase e. Auto-Scaling = Off. f. Offset = 0. Subtraction Mode standard O absolute g. Factor = 1.0. Use Constant 0 Default h. Click + (Add) icon. Auto-Scaling i. Click OK, saves preset. Offset Factor 1.0¢ Maximum 4095 + Minimum + Duplicate Delete OK Cancel Unrestricted | Published by Siemens Healthineers AG, 2025 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 03/04/2025 | QR700019081 Healthineers Page 4 of 5 Please note the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collec- tively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not neces- sarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthineers AG 2025 Unrestricted | Published by Siemens Healthineers AG, 2025 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 03/04/2025 | QR700019081 Healthineers Page 5 of 5

  • breast mr
  • sub mr breast