This job aid reviews workflow steps to postprocess 3D image data using Maximum Intensity Projection (MIP).
MR View&GO - 3D MIP Job Aid MAGNETOM Free.Max (XA40) The Show in 3D Step provides 3D postprocessing functions like MIP. The following steps outline how to perform this. 1. In MR View&GO, select the images for 3D postprocessing. 2. From Favorite Tools, select the Show in 3D icon to load images into 3D Panel. Favorite Tools 3D o Show in ImeCurve ADCGb Com porel 30 Combina ALF HAR Free.Max_Head Ref.: Congress Free.Max_Head "1/1/1 967, F, 54Y TOM Free Max Siemens_MAC Congress MAGNETOM Free Max MIR XA40 *1/1/1 967, F, 54Y CURRENT MR XA40 HFS 5/10/2021 HFS tof_$3d_tra_segmented 1.2 Bof_113d_tra_segmented 1,2 latest latest -> ModalityViewer3D.Study -- > Moda :/Viewer.3D.Stud X XA40A @ XA40A STUDY ID 7aa830116 STUDYID 783880116 RAF RAF SL 50 1 cm SPC 0.4 A TR 01.1 TE 7.1 D TR 01.1 D BW 80.0 TP F4 TE 7.1 BW 80.0 TP F4 MIP THIN : p2 MAGNINORMIDIS SP H1.7 SP A33.5 439p*440s I MPTHIN : 02 MAGNINORY/DIS2D 439p"440s | A1/PFPISAT1 Cor(10)>Sag(2) A1/PFP/SAT1 Cor>Sag(10)>Tra(-9) HE3,4;NE2 75 40301:4 / 33 40 HE3,4;NE2 *03dir4/36 40 nE HAR HAR Free.Max_Head Free.Max_Head Siemens_MAC Ref: Congress Siemens_MAC MAGNETON FIRE. Max "1M1/1967. F. 54Y ONETOM Free Max MIR XA40 *1/1/1957. F. 54Y CURRENT HFS CURRENT 5/10/2021 5/10/2021 tof :3d__segmented 1.2 tor_113d_tra_segmented latest latest -> Modalityviewer 3D.Study0 Series .. > Moda Viewer 30 Study) Series0 #XA40A # XA40A STUDY ID 7aaaa0116 STUDY ID 7aaaa0116 spc 1 cm tem A R 81.1 TE 7.1 D TR 81.1 D TP F4 TE 7.1 EW 00.0 TP F4 SP R2.2 DW 00.0 MIP THIN : p2 MAGN/NORM/DIS2D P : p2 MAGN/NORM/DIS2D SPA33.5 439p*148s I 439p 448 A1/PFP/SAT1 Sag>Cor(-9)>Tra(-4) AT/PFPISAT1 Cor>Sag(10)>Tra( 9) HE3,4;NE2 40 HE3,4,NE2 115 "113d1:4 / 36 $1130114/ 36 Unrestricted | Published by Siemens Healthcare GmbH “ Siemens Healthcare GmbH, 2022 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 01/25/2022 | HOOD05162003252798 Healthineers 3. In the 3D Panel, click the Punch Tool icon. Note: The Punch Tool is only available for MIP Thin image (Bottom Right choice in 3D panel). 3D x MPRMIP POMP MFR 2TP MPRIVAT MITHN MIP THICK Reset Parallel Curved D 4. Deselect Auto Icon. (Default = On) 5. Select Remove Outside or Remove Inside based on intended action. Remove Inside 15 Undo Redo KU Auto & Remove Outside Punch Reset 6. Depress left-mouse to draw around anatomy. Double-click to close drawing loop. Note: If drawing needs adjusting, right-click on drawing loop and select the Nudge Tool. HAK Free.Max_Head $1/1/1 967, F. 54Y CURRENT 5/10/2021 -> Modalit/Viewer 3D Study0 Serieso 3:06:00 PM Correction Pen Nudge Tool full Delete 5cm TR 81.1 SP A33.5 TE 7.1 Remove Inside FOV 270-201 Y P : P2 MAGN Remove Outside 7. Select Punch icon to apply drawing. Remove Inside 15 Remove Outside Undo Redo Auto Punch Reset Unrestricted | Published by Siemens Healthcare GmbH “ Siemens Healthcare GmbH, 2022 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 01/25/2022 | HOOD05162003252798 Healthineers Page 2 of 7 8. Repeat draw Punch Tool steps to remove additional areas in other orientations. To change orientation, right-click on Orientation cube and select the desired orientation. Ortha Sync F (feel-head) A (anterior-posterior) L (ett-right) H (head-lect) P R (right-left) Reset position in all, segments a) Select Reset position in all segments only if images were rotated in segment. b) Turn off Punch tool by pressing Esc key on keyboard. 9. In the 3D Panel, click the Radial Ranges icon. 3D x MHOMIP POMP MPR ZTP MARVAT MITHIN MIP THICK Parala Slice Range Cip Box Lock Au Unrestricted | Published by Siemens Healthcare GmbH “ Siemens Healthcare GmbH, 2022 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 01/25/2022 | HOOD05162003252798 Healthineers Page 3 of 7 10. View the 3D Sequence in the Radial Ranges Tool layout. Free-Mare HAK HRA 179/1987. ree. Max_Head CURRENT 3:05:00 PM 6:05:00 PM ................... Para MIF Manipy AMIP F TR $1.1 SP A33.5 TR 31.1 SP H1 7 TR 81 AIP 32 AMAGAINOR MIDIS20 FOV 205 236 TE 7.1 Ange Lativeen Images: 10 0 FOV 235 236 TE 7.1 FOY 235:36 MIP : p2 MAGNINORM DIS2D MIP :02 MAGN/NORM/0 82D HAR Parallel (@) Radial Free.Mar-Head -1711967 F. 54Y Preview Ref: Congress reset Select the Preset STUDY /10/2021 Angle Angle between Images 10.0 Number of Images 19 Field of View 200.0 200.0 X RAF Presets rientation Image Series Al Maria MIF Start Accept Close 11. Create radial ranges using the following steps: a) Select orientation of ranges (use the available presets or graphically adjust). Preset Select the Preset Presets Orientation Long Axis Short Axis Frontal b) Define the parameters. • Angle between Images • Number of Images • Field-of-View Angle between Images 10.0 Number of Images 19 Field of View 200.0 x 200.0 = mm Unrestricted | Published by Siemens Healthcare GmbH “ Siemens Healthcare GmbH, 2022 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 01/25/2022 | HOOD05162003252798 Healthineers Page 4 of 7 c) Adjust the slice order if needed by selecting the Orientation tab and then the Swap Order icon. Presets Orientation Image Series AL Ortho Set Axis Set Axis Swap Swap Normalize Rotate Ranges Vertical Horizontal Order orientati ... Preview d) Click Start. Start Accept Close e) In the Radial Window, define the following: • Range Series Name – enter Label for New MIP Series in Series Navigator • Image Comment – enter Label for comment on New MIP Series f) Click Accept to create a new series (or) click Reject icon (removes drawing). Note: Series Navigator displays an icon indicating a new series was created. Also, if other ori- entations are needed, change the orientation, and repeat these steps. Parallel Radial curved Preset Complete Transversal Angle between Images 10.0 Number of Images 37 Field of View 239.0 = x 234.4 - mm Presets Orientation Image Series Range Series Name|MIP COW Tumble Image Comment MIP|COW Tumble Include Reference Imag Reject Accept Close Unrestricted | Published by Siemens Healthcare GmbH “ Siemens Healthcare GmbH, 2022 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 01/25/2022 | HOOD05162003252798 Healthineers Page 5 of 7 12. Create a user preset using the following presets: a) After setting up the Radial Ranges Orientation and Parameters, select the Create Preset icon. Presets Orientation Image Series Long Axis Short Axis Frontal Create Axis Preset b) Label Preset Name and Range Series Name. c) Click OK to save. Create Range Preset ? X Preset Name MIP COW Tumble Range Series Name MIP COW Tumble AutoViews Anatomy Preset Details OK Cancel d) After saving preset, ranges are now available under User presets. Preset MIP COW Tumble Favorites User presets Ang MIP COW Tumble Unrestricted | Published by Siemens Healthcare GmbH “ Siemens Healthcare GmbH, 2022 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 01/25/2022 | HOOD05162003252798 Healthineers Page 6 of 7 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2022 Siemens Healthineers Headquarters Local Contact Information Legal Manufacturer Siemens Healthcare GmbH Siemens Medical Solutions USA, Inc. Imaging & Therapy Systems Henkestr. 127 40 Liberty Blvd. Magnetic Resonance 91052 Erlangen, Germany Malvern, PA, USA 19355-9998 Henkestr. 127 Phone: +49 9131 84-0 Telephone: +1-888-826-9702 DE-91052 Erlangen, Germany siemens-healthineers.com siemens.com/healthcare Telephone: +49 9191 18-0 siemens.com/healthcare Unrestricted | Published by Siemens Healthcare GmbH “ Siemens Healthcare GmbH, 2022 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 01/25/2022 | HOOD05162003252798 Healthineers Page 7 of 7
- MRI postprocessing
- 3d reconstructions
- mips