Siemens Healthineers Academy

MR Spectroscopy Peak Editor - Numaris X Job Aid

This Job Aid provides workflow to add a Spectral peak to a theoretical Spectrum and save it as a customer protocol.

MR Spectroscopy Peak Editor Numaris X – Job Aid MR Spectroscopy Peak Editor – Numaris X If the Spectrum shows a peak that is not included in the theoretical Spectrum (e.g., Lactate peak), the peak can be added, the curve fit recalculated and a customer protocol saved with the peak added. 1. Open the Patient Browser. 2. Right-click on Patient Name and Select > Open with > MR Spectro. 9 Open Ctrl+O Open with Favorites View as Read-Only with Suggested Batch Open MR Neurology * 4 Assign Workflow MR Oncology * Cancel Workflow MR Prostate * Search Patient with DICOM Q/R MR Spectro * Add to Demo List MR Tissue4D * 3. In the MR Spectro Analysis window. a. Select a SVS or CSI Protocol. b. Right-click on an SVS or CSI Protocol > click Edit Protocol. MR Spectro + MR_Spectro MR Spectro Analysis Germany_MA *12/1/1983, M csi_se_135,11/13/2003 3:22 PM 11/13/20 Ly csi se 135 +2 tirm tra de CSI se 30,11/13/2003 3:32 P Select Protocol ... Ly csi se 30 Edit Protocol. svs_se 30, 11/13/2003 3:37 FL Wy SVs se 30 Save Protocol svs se 30,11/13/2003 3:43 F We SVs se 30 Save Protocol As ... Delete RAW Export Export Export Spectro Compare CSI Selected Selected Selected Browser SP H47.6 SL 10 Tra Viewing MPR THICK TR 9000 TE 109 Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 2/28/2024 | QR700005768 Healthineers 4. In the Protocol Editor window. a. Select the Prior Knowledge tab. b. Click [+]. Protocol Editor - csi_se_135 Protocol name csi_se_135 Properties Prior Knowledge Post Processing Metabolite Water › Water > NAA Line shape Gaussian + Crl Use for match algorithm Cho Tolerance 15 Hz Cr2 Common Parameters Parameterization with model signal + Extra Parameters Model Signal File lemans 1 5 TH Water so_136 Browse ... Spectral filter Note: This metabolite is used for reference processing. OK Cancel 5. Select the Metabolite Template tab. a. Click on the Metabolite to show the peak information [e.g., Lac_se_135] b. Hint: match with the protocol type for the selected sequence (se_135; st_135) c. Click Select. Select Metabolite Template Show V Ww Siemens In vivo + Customer Phantom View Details Systems Protocols Metabolite Templates Model Signal Files 1.5T Metabolite Template 1H Lac_qa_st_270 Lac_se_135 Ly Lac_st_135 Le Lac_st 20 L Lac_st 270 L Lipid1 L Lipid2 Le mins_se 30 L mins_st 20 L NAA se 135 NAA se 270 Lu NAA se 30 NAA st 135 L NAA st 20 Select Cancel Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 2/28/2024 | QR700005768 Healthineers Page 2 of 6 6. Select Metabolite [e.g., Lac]. a. Click OK. b. Note: Check to make sure all the information is correct. Protocol Editor - csi_se_135 2 X Protocol name csi_se_135 Properties Prior Knowledge Post Processing Metabolite La Water Lac Line shape Gaussian Scale Factor Frequency use for match algorithm Width Phase Parameterization with model signal , NAA Model Signal File Siemens1 5 THMac_of_135 Browse ... › Cr1 Cho Spectral filter + Cr2 Pass band 0 ppm - 3.9 ppm Common Parameters + Extra Parameters OK Cancel 7. A New Protocol with the Added Metabolite is labeled with an [*] and a user icon. a. This is seen at the bottom of the Spectro Analysis list, with a customer icon. b. Left-click to open the New Protocol with the added Metabolite shown in the Spectrum. AH MR_Spectro Germany_MAC Radiologie Uni Tuebingen MR Spectro Ref.: Congress + *12/1/1983, M, 19Y Avanto syngo MR 2004V 4VB11A CURRENT MR Spectro Analysis t2_tirm_tra_dark-fluid +LPH latest -- > Spectro1.Reflmage.1 ci se 30,11/13/2003 3:32 PM si se 30 t. STUDY 1aaaa1250 11/1 3/2003 SYS 69 30.11/1 3/2003 3:37 PM 3:00:54 PM £ 50 Series 2 30,11/13/2003 3:43 PM R 1cm 1335.11/1 2/2003 3:22 PM CSI ci_se_135 1ª SP H47.6 F SL 10 Tra MPR THICK MRI 2 IMA 1 TR 9000 TE 109 FoV 160*118 NA 1 Tra>Cor(-6) HE1-4 VOX AP LR FH *tir 2d1_21/150 SIZE 10 10 10 Viewing O Voxel 106 Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 2/28/2024 | QR700005768 Healthineers Page 3 of 6 I(NAA)/I(Cr1 0.66 I(Cho)/I(Cr1) 13.08 9 1.85 8.59 % MR_Spectro Radiologie Uni Tuebingen Germany_MAC Ref.: Congress *12/1/1983, M, 19Y Avanto syngo MR 2004V 4VB11A CURRENT HFS csi_se_135 latest/csi_se_13501 Spectrum +LPH Spectro1 .Spectrum. 1 STUDY 1aaaa1 250.35 11/1 3/2003 3:22:37 PM 0.30 Series 14 0.25 NAA R 0.20 - 1.51 0.15 Real Part 0.10 0.05 0.00 TR 1500 -0.05 TE 135 NA 4 4.0 3.5 2.5 2.0 1.5 1.0 TA 07:12 Chemical shift [ppm] VOX AP LR FH HE1-4_c_4 POS A38 L16 H41 I: Integral SIZE 10 10 10 Voxel 10€ Lactate is now labeled correctly 8. To add a Metabolite to the Result Table. a. In the upper right corner menu, left-click on Define Result Table. I(NAAMI(C 1) 1.83 .65 % I(Cho)/(Cr1) 1.64 1 Define Result Table Rociologle Uni Tuebingen 9. To define a new value in the Result Table. a. Backspace over the current entry up to [I(]. b. Enter I(Lac). c. Click Add. d. Click OK. Define Result Table ? Define Result Table ? X Defined values Defined values I(NAA)/I(Cr1) (NAA)/I(Cr1) I(Cho)JI(Cr1) I(Cho)JI(Cr1) Define new value Define new value I(NAA)/(Cr1) (NAAM(Cr1) Examples >> Add Examples >> Add OK Cancel OK Cancel Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 2/28/2024 | QR700005768 Healthineers Page 4 of 6 10. To Save a Customer Protocol. a. In the MR Spectro Analysis window > right-click New Protocol > select Save Protocol As. b. Enter Protocol Name. c. Deselect Show > Siemens. d. Click Save. MR Spectro Save Protocol AS ... ? × Siemens In vivo MR Spectro Analysis OB ¥ i Customer View Details Phantom Systems Protocols Metabolite Templates Model Signal Files 1.5 T se 30, 11/13/2003 3:32 PM TH Protocol System Nucleus Sequence Purpose TE [ms] 30 sys se 30, 11/13/2003 3:37 PM sys se 30 sys_se 30, 11/13/2003 3:43 PM sys se 30 Gi se 135.11/13/2009 9:22 PM Gi se 135 1" Select Protocol .. Edit Protocol ... Save Protocol Protocol name csi_se_135 Lac Save Protocol As. Viewing Delete Save cancel 11. To open the Saved Spectroscopy Customer Protocols. a. In the MR Spectro Analysis window, select an SVS or CSI Protocol. b. Left-click on the Spectro Browser. c. Check the box next to Customer to show the saved post-processing protocol. d. New User Protocols are now shown in MR Spectro Browser > Select Protocol window. Select Protocol MR Spectro + Show Siemens In vivo Vi Customer VPhantom View Details MR Spectro Analysis Systems Protocols Metabolite Templates Model Signal Files + 1.5 T TH Protocol System Nucleus Sequence Purpose TE [ms] 31₽ [+ csi se_135 Lac 15T 1H csi se In vivo 125-145 csi_se_135,11/1 3/2003 3:22 PM csi_se 135 si se 30.11 03 3:32 PM csi se 30 sys se 30.11/13/2003 3:37 PM L sus se 30 sus 50 30 11/13/2003 3:43 PM svs se 30 Select Expur! Expor! Prurical Cance Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 2/28/2024 | QR700005768 Healthineers Page 5 of 6 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2024 Siemens Healthineers Headquarters Local Contact Information Legal Manufacturer Siemens Healthcare AG Siemens Medical Solutions USA, Inc. Imaging & Therapy Systems Siemensstraße 3 40 Liberty Blvd. Magnetic Resonance 91301 Forcheim, Germany Malvern, PA, USA 19355-9998 Henkestr. 127 siemens-healthineers.com Telephone: +1-888-826-9702 DE-91052 Erlangen, Germany siemens.com/healthcare Telephone: +49 9191 18-0 siemens.com/healthcare Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 2/28/2024 | QR700005768 Healthineers Page 6 of 6

  • mr
  • spectroscopy
  • peak
  • editor
  • numaris x