Siemens Healthineers Academy
MR Spectroscopy 1H SVS - Numaris X JobAid

MR Spectroscopy 1H SVS - Numaris X JobAid

MR Spectroscopy 1H SVS - Numaris X JobAid

MR Spectroscopy 1H SVS Numaris X Job Aid MR Spectroscopy 1H SVS – Numaris X Job Aid MR Spectroscopy is a post-processing application to analyze and evaluate MR Spectroscopy 1H datasets. It provides an evaluation of MR Single Voxel Spectroscopy (SVS) data with workflow guidance to support the diagnostic process. A novel fit-algorithm reduces the need for manual data processing and offers the user reproducible evaluation results. Info: MR Spectroscopy does not support the following image types for evaluation. • Distortion-corrected images • Images with different frames of reference (e.g., images acquired with different table positions 1. Open the Patient Browser. 2. Right-click on Patient Name and Select > Open with > MR Spectro. Open Ctrl+O 11 Ca Open with Favorites View as Read-Only with Suggested Batch Open MR Neurology Assign Workflow MR Oncology * Cancel Workflow MR Prostate * Search Patient with DICOM Q/R MR Spectro * Add to Demo List MR Tissue4D * 3. In the MR Spectro Workflow the MR Spectroscopy Evaluation assigned shows the MR Spectrum in one (1) workflow step. MR Spectro Ca + MR Spectro Analysis MR_Spectro Germany_MAC lologie Uni Tuebingen MR_Spectro Radiologie Uni Tuebingen Ref : Congress Germany_MAC Rer : Congress "1 24 /1983, M, 19Y A verno OR 2004V &V811A "1 2/1 /983, M. 19Y 11/13/2003 Tengo MR 2004V 4V811A csi_se_135,11/13/2003 3:22 PM 11/13/2003 FFS HFS Le Csi_se 135 12 1n 1re dark-nuld FH 2va se 30.01 csi_to_30,11/1 3/2003 3:32 PM L tsi_se_30 -> Sedrot Axthay svs.se_30,11/13/2003 3:37 PM PM STUDY 1:4250 STUDY 188 9 250.10 11/1 3/2003 11/1 3/2008 9.5 svs_se_30,11/13/2003 3:43 PM 3.CO. 54 PM 3.37:54 PM 9.0 L svs_se 30 R 2.5 tem 2.0 Rea Part Expert Export Selected Export Spectro Compare 1.5 Browser 1.0 0.5 Viewing TR 0000 SP H40.4 TR 1500 TE 109 FOY 310-230 TE 30 NA 128 3.0 2.5 2.0 1.0 V VOX AP LR FH TA 03:18 Chorrica shit: (pom) 'Tir 201_21/ 50 SIIE 20 20 20 FL1-4_c_4 SIZE 25 29 20 MR_Spectro Pad lo ogde Uni Tuebingen MR_Spectro Germany_MC Ref : Congress Germany_MAC 124 /1983, k, 1SY 2png0 MR 2004Y -VB11A M12/1 /983, k, 199 Findings Navigator 11/13/2003 HFS 11/13/2003 12_1se_pcr_3mm_448_pc12 CH 12 156 a00 1 448 Name Value Source -> Spedrot Feltrays 2 -> Spedrot Feltroy: 3 51 Snapshot Spectt . STUDY 1on 1250 STUDY 1ona01250 52 Snapshot Spectr. 11/1 3/2013 11/1 3/2013 3.06:47 PM 3.08:36 PM Tools 1cm SPC 5.7 A SPC 5.7 2yach Lock Full Test Hice Graphica SPA103 MER THICK TR 4210 SP L19.8 FON 310-230 FON 236-220 Cor>Tra(-7)5ag(-5) TE 102 Sag-Cor(3]>Tra(-3) YOX AP LE TH HL1-4 YOX AP LES TH SIE 20 20 20 "18:2201_15/1 50 SIZE 20 20 20 Unrestricted | Published by Siemens Healthineers AG, 2024 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 2/28/2024 | QR700005768 Healthineers 4. To perform a MR Spectro Analysis. MR Spectro Q. + a. The MR Spectro Navigator is displayed in the control area of Spectro Analysis. MR Spectro Analysis b. MR Spectro Analysis Step allows the calculation and visualization of spectroscopy results for all spectro raw data series that are csi_se_135,11/13/2003 3:22 PM Ww Csi se 135 contained in the assigned study. csi se 30,11/13/2003 3:32 PM le csi_se_30 • Automatic or Manual selection of a post-processing protocol svs se 30,11/13/2003 3:37 PM lw svs_se 30 • Automatic Calculation and svs_se 30,11/13/2003 3:43 PM Visualization of post-processing We svs se 30 results • For each spectroscopy raw data set, Export Export Export spectro Compare results are generated based on an Selected Selected Selected Browser assigned post-processing protocol • Displays individual spectra for SVS Viewing measurements c. The Spectro Object displays the Spectroscopy results. • First line is the measurement series • Second line is the post-processing protocol used Icons on left of Spectro Object. L Customer Protocol Siemens Protocol Icons right of Spectro Object Post-processing protocol was successfully applied to measurement series. Post-processing algorithm failed; hover mouse over icon to display reason for x failure and suggested corrective action. Unrestricted | Published by Siemens Healthineers AG, 2024 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 2/28/2024 | QR700005768 Healthineers Page 2 of 6 5. In the MR Spectro Analysis window, select an SVS sequence. MR Spectro + a. The Reference images and MR Spectrum results are automatically MR Spectro Analysis displayed. csi_se_135,11/13/2003 3:22 PM csi_se 135 csi_se 30,11/13/2003 3:32 PM Ly csi se 30 svs_se_30,11/13/2003 3:37 PM SVS_se 30 sVs_se_30,11/13/2003 3:43 PM Ww SVs_se 30 Export Export Selected Export Spectro Compare Selected Selected Browser 6. MR Spectroscopy SVS image results are automatically displayed. Viewing O a. Reference Images. b. Spectrum. c. Result Table. MR Spectro Q. + A Result Table (NAAMICCY1 I(Cho)/I(Cr1) 1.02 MR_Spectro Radiologie Uni Tuebin 1(mins)/1(Cr1) Radiologie Uni Tuebingen MR Spectro Analysis Germany_MAC Ref.: Congr Ref.: Congress *12M/1983, M, 19Y Avanto *12M1/1983, M, 19Y Avanto csi_se_135,11/13/2003 3:22 PM 11/13/2003 syngo MR 2004V 4YB11A syngo MR 2004V 4YB11A HFS 11/13/2003 HFS We csi_se 135 t2_firm_tra_dark-fluid +LPH Svs_se_30.01 5.0 +LPH csi se 30,11/13/2003 3:32 PM latest latest/svs_se_30/Spectrum csi_se_30 -- > Spectro1 Refimage. -- > Spectro1 .Spectrum.13 sVs_se 30,11/13/2003 3:37 PM STUDY 1aaaa1250 STUDY 1aaaa1250 4.0 la 5VS_se 30 11/1 3/2003 11/1 3/2003 3.5 60 23 SVS_se_30,11/13/2003 3:43 PM 3:00:54 PM 3.37:54 PM 3.0 5Vs_se_30 R 2.5 1cm Real Part 2.0 Colected Export selectte Pero Compare SPC 6.7 1.5 40.68 F 1.0 MPR THICK MRI 2 IMA 1 0.5 Viewing TR 9000 SP H40.4 FoV 310*230 TR 1500 0.0 TE 109 Tra>Cor(-6) TE 30 NA 1 NA 128 4.0 Spectrum VOX AP LR FH HE1-4 Reference Images VOX AP LR FH TA 03:18 "tir2d1_21/150 SIZE 20 20 20 HE1-4_c_4 Svs_se/90 I: Integral HAR Radiologie Uni Tuebingen MR_Spectro Radiologie Uni Tuebingen Germany_MAC Ref.: Congress Germany_MAC Ref: Congress *12M/1983, M, 19Y Avanto syngo MR 2004V 4YB11A *12M/1983, M, 19Y Avanto syngo MR 2004V 4YB11A Findings Navigator 11/13/2003 HFS 11/13/2003 HF'S t2_Ise_cor_3mm_448_pat2 +LPH t2_Isc_sog_rst_448 +LPH latest latest Name Value Source -- > Spectro1 Refimage.2 -- > Spectro1.Refimage.3 S1 Snapshot Spectr ... STUDY 1aaaa1250 STUDY 1aaaa1250 52 Snapshot Spectr .. 11/1 3/2003 11/1 3/2003 3:06:47 PM RP AR 1 cm Tools 1cm SPR MPR SL 3.0 SPC 6.7 [A] SPC 6.7 MRI 4 MA 1 IL Synch Lock Full Text Hide Hide Lines Reset MRI 5 MA 1 Navigati ... Graphics Timepoi ... MPR THICK TR 4000 SP L19.6 TE 104 Reference Images FoV 296-220 NA 3 Sag>Cor(3)>Tra(-3) Layout Print Export Undo Snapshot Isc2d1_13/150 SIZE 20 20 20 488R201 _15/150 VOX AP LR FH Layout Image Image SIZE 20 20 20 Unrestricted | Published by Siemens Healthineers AG, 2024 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 2/28/2024 | QR700005768 Healthineers Page 3 of 6 7. To Edit a Result Table. a. Left-click in the upper right corner menu. b. Left-click on Define Result Table. c. Note: the Result Table is automatically displayed in the upper-right-segment once a SVS sequence is selected. I(NAA)/I(Cr1) 1.83 10.65 % I(Cho)/I(Cr1) 1.64 Detine Result Table 11.38 %" Radiologie Uni Tuebingen 8. To define a new value in the Result Table a. Backspace over the current entry and Define Result Table ? X enter the new value. • Examples: click on the Examples icon Defined values to see the different suggestions that KNAAM(C1) K(Cho)I(Cr1) can be used. [e.g., I(Cho), I(Cho)/I(Cr)] b. Click Add. c. Click OK. - Define new value IKNAAM(Cr1) Examples >> Add OK Cancel Unrestricted | Published by Siemens Healthineers AG, 2024 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 2/28/2024 | QR700005768 Healthineers Page 4 of 6 9. To Delete a Result Value (if needed). Define Result Table a. Select the Result Value and left-click ? X the Minus icon. Defined values b. Click OK. I(NAA)/I(Cr1) I(Cho)/I(Cr1) Define new value I(Cho)/I(Cr1) Examples >> Add OK Cancel 10. To Reorder a Result Value (if needed). Select the Define Result Value. Define Result Table a. ? X b. Click the Up or Down Arrow icon (or) click on a Result Value and drag to a Defined values I(NAA)/I(Cr1) New Position. I(Cho)/I(Cr1) c. Click OK. Define new value I(Cho)/I (Cr1) Examples >> Add 11. To Save Results. a. Click Save and Send. OK Cancel -or- b. Click Save and Pause. Save and Send: results are stored on the system and sent to your archive. II Save and Pause: results are stored on the system. Unrestricted | Published by Siemens Healthineers AG, 2024 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 2/28/2024 | QR700005768 Healthineers Page 5 of 6 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthineers AG 2024 Siemens Healthineers Headquarters Local Contact Information Legal Manufacturer Siemens Healthineers AG Siemens Medical Solutions USA, Inc. Imaging & Therapy Systems Siemensstraße 3 40 Liberty Blvd. Magnetic Resonance 91301 Forcheim, Germany Malvern, PA 19355-9998 USA Henkestr. 127 Phone: +49 9191 18-0 Telephone: +1-888-826-9702 DE-91052 Erlangen siemens-healthineers.com Customer Care Telephone: Germany +1-800-888-7436 Telephone: +49 9191 18-0 Unrestricted | Published by Siemens Healthineers AG, 2024 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 2/28/2024 | QR700005768 Healthineers Page 6 of 6

  • MR Spectroscopy
  • 1H SVS
  • Numaris X