MR Shut down & Restart - Numaris X

This job aid provides guidance on how to perform a shut down, reboot, and place an MR System in standby for routine maintenance. This Job Aid is applicable for the following MAGNETOM MR Systems on Numaris X software: Lumina, Aera, Avanto fit, Avanto Fit BioMatrix, Altea, Sola, Sola Fit, Vida, Skyra, Skyra fit, Skyra Fit BioMatrix, Prisma, Prisma fit, Cima.X, Cima.X Fit, Viato.Mobile, and the Terra.X.

MR Shut down, Restart, & Standby – Numaris X Job Aid MR Shut down, Restart, Standby - Numaris X Job Aid This job aid provides guidance on how to perform a shut down, reboot, and place an MR System in standby for routine maintenance. This Job Aid is applicable for the following MAGNETOM MR Systems on Numaris X software: Lumina, Aera, Avanto fit, Avanto Fit BioMatrix, Altea, Sola, Sola Fit, Vida, Skyra, Skyra fit, Skyra Fit BioMatrix, Prisma, Prisma fit, Cima.X, Cima.X Fit, Viato.Mobile, and the Terra.X. Siemens Healthineers MR Customer Service recommendations: • Siemens Healthineers recommends that the MR System is shut down daily. If not per- formed daily it is recommended to shut down and reboot a minimum of once a week. • After shut down (System Off), leave the MR System off a minimum of 30 seconds before restarting/rebooting the MR system. System powered up (ON) • System currently has error messages that require an orderly shut down and reboot. • System has a scheduled shut down and restart. Shutting down the computer system When switching off the computer system, the host computer, and MaRS (Measurement and Reconstruction System) also shuts down. • Save all patient and postprocessing data at the syngo Acquisition Workplace. • Close all workflows, examinations, and applications. • The spine coil on the patient table must be fully connected into the coil sockets. All other coils should be removed from the patient table. • Patient table must be in the home position. (i.e., table up and completely out of the bore). Unrestricted | Published by Siemens Healthineers AG, 2024 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 02/03/2024 | QR700018199 Healthineers 1. On the access bar, click the Home icon to open the Home screen. 2. On the Home screen, click the Shut Down icon and choose Shut Down System. Healthineers x System Check myExam Cockpit Examination Restart System Shut Down System Restart Workplace Standby System C 3. Shut Down System window opens, click Shut down (shut down process displayed). a. The computer shuts down. b. Shut down turns on the power saving mode for the MR cooling system. Shut down System ? × ? Do you want to shut down the system? If any applications/studies are still open, then the system will attempt to save all studies/results and to close all open applications. Shut down Cancel Unrestricted | Published by Siemens Healthineers AG, 2024 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 02/03/2024 | QR700018199 Healthineers Page 2 of 6 4. Monitor goes Off (blank) SIEMENS a. Light on the monitor changes from green to amber. b. It is now it is safe to turn off the system. TO REMOVE FIELD 5. Press the SYSTEM OFF button on the alarm box. Restarting the syngo MR Acquisition Workplace • Coils on the patient table are fully connected in the coil sockets. • The spine coil on the patient table must be plugged in and fully connected into the coil sockets. All other coils should be removed from the patient table. • Position of the patient table must be up and all the way out of the MR System. • Save all patient and postprocessing data. Hints: • Leave the MR system off for a minimum of 30 seconds before restarting. • Do not move the patient table, tabletop, or connect coils when re-starting/rebooting. 1. On the Access bar, click on the Home Screen icon. 2. On the Home screen, select the Shut Down icon and choose Restart Workplace. Healthingers > X System Check myExam Cockpit Examination Restart System Shut Down System Restart Workplace Standby System G Unrestricted | Published by Siemens Healthineers AG, 2024 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 02/03/2024 | QR700018199 Healthineers Page 3 of 6 3. The Restart Workplace window opens, click Restart Workplace. The screen will display the restart process. a. syngo software on the workplace shuts down and restarts the measurement and Restart Workplace ? X reconstruction (MaRS) system software. Do you want to restart this workplace? b. Operating systems are not shut down. ? If any applications/studies are still open, then the system will attempt to save all studies/results and to close all open c. Computer system boots automatically. applications. When restarting (booting) the system, a Restart Cancel splash screen is displayed on the work- place. 4. Wait until the system is ready for measurement, you will hear three (3) knocks/beeps. The MR Scanner & Acquisition icon looks like this when the system is ready. System Startup at the Alarm Box (System On) – process if MR System is currently shut down. • All daily functionality checks are completed. • Coils on the patient table are fully connected in the coil sockets. • The spine coil on the patient table must be plugged in and fully connected into the coil sockets. All other coils should be removed from the patient table. • The position of the patient table must be up and all the way out of the MR System. 1. On the Alarm Box, turn the key switch to the right SIEMENS (skip step if key switch is on). 2. Press the SYSTEM ON button on the alarm box. 3. The SYSTEM ON LED lights up and the MR system TO PRESS TO BEIMONE FIELD. is switched ON. 4. The software automatically starts at the syngo Acquisition Workplace. 2 TIM CHE 1 ED ED - Important Notes: • The MR System is typically only shut down and restarted at the alarm box if there is a system error. OR • If MR System timer was activated. Unrestricted | Published by Siemens Healthineers AG, 2024 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 02/03/2024 | QR700018199 Healthineers Page 4 of 6 Essential information for MAGNETOM Skyra fit After switching on the syngo MR Acquisition Workplace, the system requires approximately 18 minutes to warm up and get ready for data acquisition. Shutting down the system (System Off) • Switches the MR system Off and shuts down the computer system (software). • If the MR system is turned Off (software or host computer) for a lengthy period, press the Off button on the Alarm Box. • Shut down the syngo MR Workplace prior to the MR syngo Acquisition Workplace, to avoid any data loss. (i.e., if applicable). Starting/Ending Standby • If you do not intend to perform measurements for a longer time, or only need to edit or evaluate images, save energy by enabling Standby mode. • MaRS shuts down and the power saving mode of the MR cooling system turns on. • You cannot perform measurements in Standby mode. 1. The Home screen is open. 2. To start Standby, click the Shut down icon and select Scanner (System) Standby. 3. In the Standby System window, click Standby. 4. To end Standby, press the SYSTEM ON button on the alarm box. SIEMENS * System Check myExam Cockpit Examination Restart System Shut Down System Restart Workplace Standby System G Unrestricted | Published by Siemens Healthineers AG, 2024 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 02/03/2024 | QR700018199 Healthineers Page 5 of 6 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collec- tively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not neces- sarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthineers AG 2024 Siemens Healthineers Headquarters Local Contact Information Legal Manufacturer Siemens Healthineers AG Siemens Medical Solutions USA, Inc. Imaging & Therapy Systems Siemensstraße 3 40 Liberty Blvd. Magnetic Resonance 91301 Forcheim, Germany Malvern, PA 19355-9998 USA Henkestr. 127 Phone: +49 9191 18-0 Telephone: +1-888-826-9702 DE-91052 Erlangen siemens-healthineers.com Customer Care Telephone: Germany +1-800-888-7436 Telephone: +49 9191 18-0 Unrestricted | Published by Siemens Healthineers AG, 2024 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 02/03/2024 | QR700018199 Healthineers Page 6 of 6

  • shutdown
  • shut down
  • restart
  • reboot