Siemens Healthineers Academy

MR Free.Max System Overview

MR Free.Max System Overview

SIEMENS Healthineers Discover your System – MAGNETOM Free.Max Template Effective Date: 27 MAY 2019 | HOOD05162003010284 Effective Date: 02 AUG 2021 | HOOD05162003202305 US HRT Effective Date: 10.5.2021| HOOD05162003220791 Unrestricted © Siemens Healthineers, 2021 MAGNETOM Free.Max SIEMENS Healthineers AI‐driven Technology Get more info on a Open information on Learn more on PEPconnect by topic: the website clicking on the related link thineers myExam Companion Intuitive operation for any professional BioMatrix technology and consistent results by different Reduce patient variation by adapting scanning modes: to single patient to be scanned: MAGNETOM Free.Max myExam Autopilot: Automated push‐  Select&GO: For automated and  button scan workflows lealthingers faster positioning myExam Assist: Semi‐automated scan Jog Wheel: Design to support   workflows with guidance and flexibility easy positioning  myExam Cockpit: For protocol customization syngo Virtual Cockpit Embedded into software for supporting remote operation Effective Date: 02 AUG 2021 | HOOD05162003202305 US HRT Effective Date: 10.5.2021| HOOD05162003220791 Unrestricted © Siemens Healthineers, 2021 Operator´s Room SIEMENS Healthineers myExam Companion – Your User Interface Get more info on Open information Open PEPconnect a topic: on the web training material myExam Autopilot myExam Assist myExam Cockpit Brain Assist SIEMENS Healthineers Smile x 11 1e ... N. Cwave Soire MeHering C.I .... O Automate intelligently Flexible and guided Customize intuitively for professionals for advanced professionals Effective Date: 02 AUG 2021 | HOOD05162003202305 US HRT Effective Date: 10.5.2021| HOOD05162003220791 Unrestricted © Siemens Healthineers, 2021 Operator´s Room – Overview SIEMENS Healthineers Display, Intercom Console & myExam Companion Get more info on Open PEPconnect a topic: training material Workstation: • Optional touch monitor to support autopilot workflows without requiring mouse and keyboard 000900000 • Optional wall mount system to minimize the needed space New Intercom console: Including communication and system status management (e.g., ON/OFF button) Effective Date: 02 AUG 2021 | HOOD05162003202305 US HRT Effective Date: 10.5.2021| HOOD05162003220791 Unrestricted © Siemens Healthineers, 2021 Examination Room SIEMENS Healthineers Table Table movement: Max. range 2150 mm I max. speed 200 mm/s Scan range: 1400 mm SlideConnect coil sockets: The two 1 coil sockets are positioned at the end of the table. Contour coils can be connected to both sockets for higher workflow 2 flexibility. Effective Date: 02 AUG 2021 | HOOD05162003202305 US HRT Effective Date: 10.5.2021| HOOD05162003220791 Unrestricted © Siemens Healthineers, 2021 MAGNETOM Free.Max SIEMENS Healthineers Local Coil Portfolio Contour S Coil BioMatrix Contour L Coil BioMatrix Contour L Coil Coil Link Contour Coils with SlideConnect 45 x 27 cm² • • E.g. for small joints • 6 elements · 63 x 42 cm2 63 x 42 cm² • Exchangeable coil cable • • Blanket‐like coils for increased comfort · E.g ., for abdomen, lung E.g., for abdomen, lung for Contour S & L • Improved ergonomics with SlideConnect • · 6 elements • 6 elements • 151 cm length • Plate‐type connectors for better cleanability & reliability Head/Neck Coil Spine Coil Positioning aids • Optimized positioning Better patient comfort • • Fixed spine coil • Fixed 9° tilt for improved patient in the isocenter comfort - • 9 elements • DirectConnect • 12 elements *without cover Effective Date: 02 AUG 2021 | HOOD05162003202305 US HRT Effective Date: 10.5.2021| HOOD05162003220791 Unrestricted © Siemens Healthineers, 2021 MAGNETOM Free.Max SIEMENS Healthineers Coils for Body Region Get more info on Open PEPconnect a topic: training material BioMatrix Contour L coil Contour S coil (unilateral) BioMatrix Contour L coil (bilateral) BioMatrix Contour L coil Abdomen Hip/Pelvis Head/Neck coil Thorax/Lungs Contour S coil Head Knee Head/Neck (posterior) + Spine Coil Contour S coil C‐Spine Contour S coil Contour S coil Ankle/Fore foot Shoulder Hand/Wrist Spine Coil Spine Coil T‐Spine L‐Spine Effective Date: 02 AUG 2021 | HOOD05162003202305 Effective Date: 02 AUG 2021 | HOOD05162003202305 Author | Department 7 US HRT Effective Date: 10.5.2021| HOOD05162003220791 US HRT Effective Date: 10.5.2021| HOOD05162003220791 Unrestricted © Siemens Healthineers, 2020 Unrestricted © Siemens Healthineers, 2020 MAGNETOM Free.Max SIEMENS Healthineers Application technologies Get more info on Open PEPconnect a topic: training material Parallel imaging Simultaneous Multi‐Slice  iPAT  CAIPIRINHA VIBE  SMS EPI  CAIPIRINHA Space  SMS TSE  SMS Averaging  CS SPACE  Deep Resolve Gain  Deep Resolve Sharp Compressed Sensing Deep Resolve Effective Date: 02 AUG 2021 | HOOD05162003202305 US HRT Effective Date: 10.5.2021| HOOD05162003220791 Unrestricted © Siemens Healthineers, 2021 Operator’s Room SIEMENS Healthineers Clinical Applications Get more info on Open information Open PEPconnect a topic: on the web training material Neuro Spine MSK Abdomen *** Angiography Pelvis Thorax Effective Date: 02 AUG 2021 | HOOD05162003202305 US HRT Effective Date: 10.5.2021| HOOD05162003220791 Unrestricted © Siemens Healthineers, 2021 MAGNETOM Free.Max SIEMENS Healthineers . High‐V MRI Scanner Get more info on a Open information on Learn more on PEPconnect by topic: the website clicking on the related link ........ High‐V MRI Digitalization is rapidly transforming MR imaging by applying highly efficient acquisition HealthMENS :: techniques and deep learning‐based reconstruction. High‐V MRI takes the power of digitalization and deliberately applies it to a new field strength of 0.55T with inherent clinical benefits. Digitalization + 0.55T MAGNETOM Free.Max Healthineers - - - - - - - -- --------- Imaging techniques to enhance image Clinical benefits of lower field strength: quality and for faster scan times: Less susceptibility artifacts ‐ Simultaneous Multi‐Slice Improved implants imaging ‐ ‐ Deep Resolve Gain & Sharp Pulmonary imaging capable ‐ ‐ Compressed Sensing ‐ Effective Date: 02 AUG 2021 | HOOD05162003202305 US HRT Effective Date: 10.5.2021| HOOD05162003220791 Unrestricted © Siemens Healthineers, 2021 MAGNETOM Free.Max SIEMENS Healthineers Overview Get more info on a Open information on Learn more on PEPconnect topic: the website by clicking on the related link The world’s first 80 cm bore Comfort for your patients and their positioning SIEMENS Healthineers Simplified infrastructure for easy siting MAGNETOM Free. Max Small footprint: 24 m² HeOS HOMENS Lightweight: < 3.2 t Low transportation height: < 2 m DryCool technology Only 0.7 l liquid helium Fully sealed magnet No quench pipe Effective Date: 02 AUG 2021 | HOOD05162003202305 US HRT Effective Date: 10.5.2021| HOOD05162003220791 Unrestricted © Siemens Healthineers, 2021 Free. Max MAGNETOM Free.Max SIEMENS Healthineers pecifications Summary of Specifications AV High‐V MRI The world’s first 80 cm bore Power of digitalization & 0.55T SIEMENS 165 cm magnet length incl. covers 50 x 50 x 45 cm³ FoV Healthineers B80 gradients Our most compact MRI Max. amplitude: 26 mT/m 24 m² | < 3.2 t | < 2m Max slew rate: 45 T/m/s MAGNETOM Free. Max Tim Tim [51x24] Image processing innovations Direct RF HeDEHOMENS Deep Resolve Gain & Sharp 4G 2 slide connects SMS | Compressed Sensing | CAIPIRINHA CRE DryCool technology BioMatrix technology 0.7 l liquid helium Select&GO positioning < 24 h ramp up after quench myExam Companion Intuitive operation for any professional Effective Dat Effective Date: 02 AUG 2021 | HOOD05162003202305 US HRT Effective US HRT Effective Date: 10.5.2021| HOOD05162003220791 Unrestricted © Siemens Healthineers, 2021 C SIEMENS Healthineers Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. © Siemens Healthcare GmbH 2021 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84‐0 siemens‐healthineers.com Effective Date: 02 AUG 2021 | HOOD05162003202305 US HRT Effective Date: 10.5.2021| HOOD05162003220791 Unrestricted © Siemens Healthineers, 2021

  • MR
  • Free.Max
  • MAGNETOM
  • XA40
  • myExam
  • Autopilot
  • myExam Companion