MR Free.Max myExam Autopilot Workline Dynamics
MR Free.Max myExam Autopilot Workline Dynamics
MR MAGNETOM Free.Max myExam Autopilot Workline Dynamics Job Aid The workline gives you an overview of the steps which need to be done for specific exam programs and modes. It changes dynamically during the exam. Brain Autopilot | Standard | 20:04 Remaining Time SAR 0:32 O 2:58 4:28 2:12 2:58 O 6:56 AAHead_Scout Start Stimu N AHead_Scout t1_se_sag Huid tra p 2 ep2d_diff scan trace . 12_tse_tra Check Image Quality Inject contras Summary It can also include the steps for image checks and any needed interaction step for the examination, e.g., contrast injection, spine planning. Planning Step Contrast Step It follows the workflow status and adapts automatically if changes are done. o In fact, step icons and workline change during the examination to provide an easy understanding of the current situation. Above the workline, you can always see the current programs, mode and the Head | Standard Scan | 3:30 remaining time remaining scan time. o If the program is modified (e.g., SAR INM mode or decisions are changed in the Exam Settings), the Stimu NM workline and its information are adapted to show the new settings, the new workflow steps, and the scan duration. The needle on the icon indicates the current running step or the step ready to start. The white highlight of the border 0:30 O 0:30 1:00 indicates the step selected at the moment. Localizer Quality Check T1 sag dark 12 tra T2 Each steps shows the scan time before and during the scanning and can be fluid accessed to review the area to be scanned or the created image as well as further information by clicking on the respective icon of the step. Restricted by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2021 Master Template Effective Date: 05 MAR 2020 | HOOD05162003074494 SIEMENS US HRT Effective Date: 10.6.2021 | HOOD05162003220932 Job Aid Effective Date: 28 JUN 2021 | HOOD05162003187662 Healthineers Page 1 of 4 Job Aid | Workline Dynamics US HRT Effective Date: 10.6.2021 | HOOD05162003220932 Effective Date: 28 Jun 2021 | HOOD05162003187662 Relative information and options for the selected step are displayed in the details area (see below). ealthineersR Anatomic regions were detected successfully AAHead_Scout Scan time Cr17 min Repeat stup Brain Autopilot | Sede | 16:55 bemining hima SAR O O 2:58 1.28 158 Shmu NM Check Image 12 tue dart epit dif 12 hersa 8 0 IN 10:16:11 AM Please Note: Steps cannot be re-ordered from the myExam Autopilot view. The workline control shows the step which is currently running or ready to get scanned. o In addition, you can perform AAHead_Scout Start further actions here, such as Start/Stop or Pause the workflow. If you click Pause while a measurement is still in progress, the measurement is first completed and 114 then the workflow pauses. o If pause is active, you cannot start a step. o The workflow resumes after the pause is deactivated. Restricted by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2021 Master Template Effective Date: 05 MAR 2020 | HOOD05162003074494 SIEMENS US HRT Effective Date: 10.6.2021 | HOOD05162003220932 Job Aid Effective Date: 28 JUN 2021 | HOOD05162003187662 Healthineers Page 2 of 4 Job Aid | Workline Dynamics US HRT Effective Date: 10.6.2021 | HOOD05162003220932 Effective Date: 28 Jun 2021 | HOOD05162003187662 Overview of Icons’ Dynamics Preparing Pending Running Done Viewed :58 0:52 3:45 ....... Recon Quality Check Summary Contrast Step Planning Step o Restricted by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2021 Master Template Effective Date: 05 MAR 2020 | HOOD05162003074494 SIEMENS US HRT Effective Date: 10.6.2021 | HOOD05162003220932 Job Aid Effective Date: 28 JUN 2021 | HOOD05162003187662 Healthineers Page 3 of 4 Job Aid | Workline Dynamics US HRT Effective Date: 10.6.2021 | HOOD05162003220932 Effective Date: 28 Jun 2021 | HOOD05162003187662 Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. © Siemens Healthcare GmbH 2021 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com Restricted by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2021 Master Template Effective Date: 05 MAR 2020 | HOOD05162003074494 SIEMENS US HRT Effective Date: 10.6.2021 | HOOD05162003220932 Job Aid Effective Date: 28 JUN 2021 | HOOD05162003187662 Healthineers Page 4 of 4
- MR
- Free.Max
- MAGNETOM
- XA40
- myExam
- Autopilot
- myExam Companion