MM Radiation Therapy Image Suite (RTiS) - Changing the Default Patient Marking Render
THis job aid will assist with changing the default layouts for patient marking functions.
Change the Default Patient Marking Render in RTiS and Sim&GO MM Radiation Therapy Image Suite (RTiS) VA40 Sim&GO VA40 and syngo.via VB60 When using the Patient Marking function in RTiS, the default layout includes a skin rendering. If a POI (Point of Interest) is placed, the position of the laser will appear on the skin rendering. A site may choose to change the default image from a skin rendering to something else. Note: There are a few different ways to change the default VRT and this method is only one ex- ample. This example will use RTiS as the program and Osseous Tissue as the new default render- ing. 1. Load a series in the RTiS program, Patient Marking tab. 2. Using the lower left corner menu, select VRT (Volume Render Technique) and right- mouse-click, and select VRT Gallery. R 10 cm A VRT VRT Gallery 700 88 Mir Define the Color of the VRT volume Send To Context Menu MPR SP R2.0 SP R2.0 10/11/2019 10/11/2019 Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06 October 2023 | QR700001522 Healthineers 3. From the VRT Properties box, right-mouse-click on the Patient Marking icon and select Copy. VRT Properties ? Object Settings SPA 10/1 Modality CT Body Part Cardio 8:20 Copy Paste Patient Marking Set As Default Blue Coronaries Red Myocardium Rename Delete Myocaldium Ca Scoring Cinematic Aortic Valve Viewy Calcium Tissue Classification General Settings OK Cancel 4. Paste the image and note the new name and location. VRT Properties Object Settings Modality CT Body Part Cardio Myocardun Dadk. Myocadum Gray MyocadunSnoot Myocardin Solid Paque NUS Prosthetic Valves Copy of Patient MAL CI VRI Tosur Classification >> General Settings OK Cancel Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06 October 2023 | QR700001522 Healthineers Page 2 of 9 5. Right-mouse-click and select Rename. Rename the copy (#1 added for demonstration). Note: Making a copy of the original and renaming it preserves the original rendering. VRT Properties ? x Object Settings Modality CT Body Part Cardio Myocardum Dark Myocardium Gray MyocardiumSmoot Myocardium Solid h Plaque IVUS Prosthetic Valves Patient Markin CT VRT #1 Copy Tissue Classification Paste Set As Default Rename General Settings Delete OK Cancel Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06 October 2023 | QR700001522 Healthineers Page 3 of 9 6. Navigate through the gallery list until you find the new rendering for use. (Osseous Tissue in this example). VRT Properties ? X Object Settings Modality CT Body Part Extremities Bone Metal DE Gout Osteous and Soft Osseous Shaded Tissue Osseous Tistue Runoff 1 Runoff 2 Runoff 3 Tissue Classification General Settings OK Cancel Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06 October 2023 | QR700001522 Healthineers Page 4 of 9 7. Right-mouse-click, and select Copy, Paste, and Rename as in the previous step. VRT Properties ? X Object Settings Modality CT Body Part Extremities Bone Metal DE Gout Osteous and Soft Osteous Shaded Tissuc Osseous Tissue 111 Runoff Runoff 2 Runoff 3 Tissue Classification General Settings OK Cancel Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06 October 2023 | QR700001522 Healthineers Page 5 of 9 8. Return to the original Patient Marking icon, right-mouse-click, and select Rename. Copy the original name. VRT Properties ? X Object Settings SP 10/ Modality CT Body Part Cardio 8:20 Patient Marking CT VRT #1 Coronary Cinematic Blue Coronaries Red Myocardium R Myocardium Cinematic Patient Marking CT Aortic Valve View Calcium Tissue Classification General Settings OK Cancel Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06 October 2023 | QR700001522 Healthineers Page 6 of 9 9. Paste the name to the new icon (Osseous Tissue in this case). A popup box will appear and select Yes. Note: Copy #1 preserves the original name of the icon. nage Suite VRT Properties X uite 7 IMA ~269 SP H1766.0 Object Settings Overwrite VRT Preset x Modality CT Body Part Extremities ? The name you have entered is already being used by another VRTpreset. If you continue, this preset will be overwritten. Are you sure you want to overwrite the existing preset? "Osseous Tissue Deseous Ticque Bone Metal DE Go Yes NO Osseous and Soft Osseous Shaded Runoff 1 Runoff 2 Tissue Classification gator Findings >General Settings ures POI Absolute Name Type OK Cancel IsoCenter ISOCENT ... 10. Select OK in the VRT Properties box. 11. Save and Pause the Series. Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06 October 2023 | QR700001522 Healthineers Page 7 of 9 12. Test by reopening a different patient in RTiS. 2 IMA -83 SP F249.0 Lunge 3.00 Br40 83 01/19/2021 9:39:14 AM Structure Set_1 UNAPPROVED 2 IMAn.a. FRM rio SP R0.1 SP RO.1 SP ROM Lunge 3.00 Br40 S Lunge 3.00 Br40 Lunge 3:00 Et 01/19/2021 01/1 9/2021 01/19/2020 9:39:14 AM 9:39:14 AM 9:39:14 AM 4 cm Create at Sat To Maria Crosshair Crosshair MOVE 13. The series should open with the new default rendering. Note: This new rendering default will also appear in Sim&GO once changed. Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06 October 2023 | QR700001522 Healthineers Page 8 of 9 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2023 Siemens Healthineers Headquarters Local Contact Information Legal Manufacturer Siemens Healthcare GmbH Siemens Medical Solutions USA, Inc. Siemens Shanghai Healthcare Sector Henkestr. 127 40 Liberty Blvd. Medical Equipment Ltd. 91052 Erlangen Malvern, PA 19355-9998 USA 278 Zhou Shu Road Germany Telephone: +1-888-826-9702 Shanghai 201318 Phone: +49 9131 84-0 Customer Care Telephone: P.R. China https://www.siemens-healthineers.com +1-800-888-7436 Telephone: +1 847 304 7700 Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06 October 2023 | QR700001522 Healthineers Page 9 of 9
- mm radiation therapy image suite
- rtis
- somaris 7
- somaris 10
- mip
- maximum intensity projections