
MI PET Biograph™ mCT & Biograph Vision™ VG80 SmartSimulator Workbook
This workbook will take you through your lab sessions with Biograph™ mCT and Biograph Vision™ VG80 software in the SmartSimulator.
Target group: All users
Recommended to be viewed on the following devices: All (incl. tablet and smartphone)
SIEMENS Healthineers SmartSimulator Workbook MI PET Biograph™ mCT & Biograph Vision™ VG80 smartsimulator.siemens-healthineers.com/ SIEMENS Healthineers BIOGRAPH Vision SIEMENS Healthineers .. Unrestricted | Published by Siemens Healthineers AG © 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Effective Date: 26 Aug 2024 | QR700011883 SmartSimulator Workbook | MI PET VG80 Workbook Effective Date: 26 Aug 2024 | QR700011883 Table of Contents Foreword 3 Disclaimer 4 Logging into MI SmartSimulator 5 Start-up 6 Patient Registration 8 Acquiring a Simulated Scan 9 Viewing Patient Data in TrueD 16 Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2023 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 2 of 21 SmartSimulator Workbook | MI PET VG80 Workbook Effective Date: 26 Aug 2024 | QR700011883 Foreword Dear participant, Welcome to the SmartSimulator workbook. This workbook guides you through your lab sessions with Biograph mCT™ and Biograph Vision™ VG80 in the SmartSimulator. You will have a maximum of 8 hours with your SmartSimulator. Make the most of it! Have some fun and explore what it can do. Good luck and we hope you enjoy your SmartSimulator time! Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2023 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 3 of 21 SmartSimulator Workbook | MI PET VG80 Workbook Effective Date: 26 Aug 2024 | QR700011883 Disclaimer Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means be regarded as a substitute for the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product-related claims, or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of these Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the latest information. The reproduction, transmission, or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration- dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. © Siemens Healthineers AG 2024 Siemens Healthineers Headquarters Siemens Healthineers AG Siemensstr. 3 91301 Forchheim Germany Phone: +49 9191 18-0 siemens-healthineers.com Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2023 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 4 of 21 SmartSimulator Workbook | MI PET VG80 Workbook Effective Date: 26 Aug 2024 | QR700011883 Logging into MI SmartSimulator Log on to the MI SmartSimulator by navigating to the login webpage: https://smartsimulator.siemens- healthineers.com/#/ SIEMENS Healthineers SmartSimulator EN My Subscriptions tact U .... SmartSimulator Your simulated hands-on experience with your medical equipment. Once logged in, go to My Subscriptions, and select View Details. SIEMENS Healthineers' Smart Simulator Home My Subscriptions Contact Us All Subscriptions (5) $169982 Subscription ID : 5169982 Start Date : 26 September 2023 Owner : pralhad.joshi@siemen .. Total Hours : 171 Hours Available : 70 hr 28 min No of Users : 25 Storage 25 GB Valid Until : 25 September 2024 Subscription Active View Details Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2023 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 5 of 21 SmartSimulator Workbook | MI PET VG80 Workbook Effective Date: 26 Aug 2024 | QR700011883 Select the simulator you want to use and choose Launch. Simulators (1) MI PET Biograph mCT Vision VG80A Launch After you enter the simulator for the first time, you may need to wait a few minutes until the software is fully booted up and ready. Then select Connect. C Refresh State Start Datetime Action running 12:57 PM, 20 Jun 2024 × Connect The simulator will launch into a new window. You are now ready to begin. Start-up You are now in the PETsyngo user interface. There may be some system generated nuisance windows. Click X or Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2023 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 6 of 21 SmartSimulator Workbook | MI PET VG80 Workbook Effective Date: 26 Aug 2024 | QR700011883 OK to close them. Also, click Cancel when the checkup screen appears. Examination 5 C: \Windows\SYSTEM32\cmd.exe 3:\Windows \system32>met use /del . /Y There are no entries In the List. BUIMOIA E:\windows\system)2>set use x: \\10. 10. 10. 16\582213af26454098af73df53b549cdfd /user :5422134f26454098af73df5365a9cdfd 5a2 2134f264540984 f73df5365 The command completed successfully. 3:\Windows \system32>pau Press any key to contin constancy has to be performed Please run Quality Constancy bull OK Simulation Checkup ST B2>n For best image quality please run checkup procedure. Les Please leave the scan room. The table will move out of the gantry automatically and the 32>n gantry will automatically tilt back to zero position. bd7f 170f X-rays will be produced during the checkup procedure. eted Click on Checkup to start procedure. 32>p ont Click on Cancel to skip procedure. Checkup Cancel Help ...... Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2023 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 7 of 21 SmartSimulator Workbook | MI PET VG80 Workbook Effective Date: 26 Aug 2024 | QR700011883 Patient Registration Exercise: Registering a Patient In this exercise, you will learn how to register a patient. There are several ways to register a patient. One way is to: 1. Select Register under the Patient dropdown in the main menu bar at the top of the screen. 2. Enter the patient information. Only the fields in bold are required: Patient Registration X PROCEDURE Last name TEST Accession No 2 First name JOE Requested Patient ID 12345 procedure(s) Date of birth 03-Apr-1968 [dd-MMM-yyyy] Sex · Male Female Other Study list Age 55 Years Height ft in Weight 175 Ibs OZ Metric Add Delete Study HOSPITAL Referring physician INSTITUTION Admitting diagnosis Institution name Ward Admission ID 1. Performing physician 3 1. Operator Preregister Exam Search Cancel Emergency Help (1) Last Name (2) Patient ID (3) Date of Birth (Hint: Enter an age and the DOB will automatically populate) (4) Sex (5) Weight Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2023 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 8 of 21 SmartSimulator Workbook | MI PET VG80 Workbook Effective Date: 26 Aug 2024 | QR700011883 3. Click Exam to continue. 4. You can now choose an aqcuisition protocol. For this example, select the Onco_LowDose protocol. 5. Click OK on the Patient Model Dialog. Patient Model Dialog Adult Dun En Protocol . Replace . Child Append ar di Topogram « Cut SCU . Keep RT Auto reference lines None Cardio CardioDualGated CardioDualGated_CardioMatching German CardioGated_CardioMatching CardioGatedMFL CardioGatedMFL_CardioMatching OK Cancel CardioGatedRestStress CrossCalibration Test, Joe Gantry_Offset NEMA AC Total mAs: NEMA_Coregistration_Accuracy Neuro Onco_LowDose OncoCBM_LowDose OncoDynamic OncoDynamicCBM OncoDynamicCBM_Patlak OncoHeadNeck OncoListmode OncoPETonly OncoPETonly_Topo OncoPETTopo OncoPETTopoCBM OncoRespGated OncoRespGated_RespMatching OncoRespGatedCBM OncoRespGatedCBM_RespMatching OncoRespGatedCBMDDG Hold TUU.U Acquiring a Simulated Scan Exercise: Acquire a PET/CT Scan In this exercise, you will learn how to acquire a PET/CT scan. Each protocol will have a chronicle (or steps) that will be performed. The first step is the Topogram. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2023 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 9 of 21 SmartSimulator Workbook | MI PET VG80 Workbook Effective Date: 26 Aug 2024 | QR700011883 Please note: If a yellow exclamation mark is seen, you will need to change the Table Position to -750 and hit enter on the keyboard. A simulated control box will appear on the screen. You will then be prompted to click and hold the Move Table button. Topogram mA 35 CT LowDose KV 120 -1 Pause Scan time 5.88 s PET Slice 0.6 mm Topogram length =1024mm Tube position . Top Bottom Latera Comments Table: Position Height 400.0 - 100.0 Load Hold Recon ove table and gantry on weight 1774.0 J 1001 1. Click Load and then click the Start button to begin the Topogram acquisition. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2023 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 10 of 21 SmartSimulator Workbook | MI PET VG80 Workbook Effective Date: 26 Aug 2024 | QR700011883 Onco_LowDose (Adult) Topogram CT LowDose RT Pause PET Load Hold Recon Recon Topogram Press START 35 3 SIEMENS CT LowDose RT KV 120- O Pause Scan time 5.88 PET 00 Topogram - STOP Tube pc Comm scanning on weight -750.0 100.0 2. Once the Topogram is acquired, adjust the FoV (purple box) over the patient. Do this by clicking on the circle in the center to move the FoV to the start position in the head, and then click the small box in the bottom to extend or shorten the FoV. If you can’t see the entire purple box, zoom out on the image to find purple box. Click the Load button to begin the CT acquisition. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2023 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 11 of 21 SmartSimulator Workbook | MI PET VG80 Workbook Effective Date: 26 Aug 2024 | QR700011883 12345 *06-Apr-1968, M, 55Y Biograph1 28_Vision 600 Edge VG80A 06-Apr-2023 H-SP 13:42:36.43 1 IMA 1 TOP 1 SP -750.5 SP SP 2 ₩355.5 LEN -1644.0 788.5 GT: FoV 0.0 CE 780 R 10cm: KV 120 mA 35 TI 5.9 GT 0.0 1024 070 Tr60.fOn.UOPO .. 1i .. 350 Onco_LowDose (Adult) Test, JOE Topogram Eff. mAs 11 CT LowDose RT KV 80 1 Pause Scan time 4.91 Delay PET Slice No. of images El Comments Range: Begin Hold -855.5 Load Recon Recon Routine Sc 3. An additional Load button will appear. Click Load. Scan Controller X The recon job running during measurement, or a recon job starting after measurement (auto recon) contains HD FoV. Reconstruction with a HD Fov can lead to image artifacts. Load Cancel 4. On the control box, click and hold the Move Table button to move the table. It will stop when it is in the optimal position. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2023 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 12 of 21 SmartSimulator Workbook | MI PET VG80 Workbook Effective Date: 26 Aug 2024 | QR700011883 Onco_LowDose (Adult) Test, JOE 12345 Topogram Eff. mAS 11 SIEMENS CT LowDose Press MOVE KV 80 O Gy Pause Scan time + 4,91 Delay PET .3ª STOP No. of in Comm e table and gantry Range: Begin on meight -855.5 2 1774.0 -J 100.0 Load Cancel Move Recor 5. Click Start to begin the CT scan. Test, JOE H Hospital 12345 "06-Apr-1968. M. 55Y Biograph1-28-Vision-609-Edge VG804 06-Apr-2023 H-SP 13:42:36.43 1 IMA 1 SP-750.5 1-355,6 SP LEN -1644.0 788.5 GT FOV 0.0 500 10cm KV 120 MA 35 TI 5.9 OT 0.0 1024 0/0 Tr60.1On. UOPO .. 11 .. Onco_LowDose (Adult) Test, JOE Topogram Eff. MAS 11 SIEMENS CT LowDose Press START 80 O GY Pause Scan time + 4.91 00 Delay PET STOP No. of in Commi Kart scanning" Range: Begin on height -855.5 2] -736.5 - 100.0 Load Cancel Recor 6. When the CT is finished, you will need to enter a Dose value for the PET to continue (entering an injection time is optional). Click OK on the Invalid Dose dialog box and enter the dose in the PET chronicle. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2023 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 13 of 21 SmartSimulator Workbook | MI PET VG80 Workbook Effective Date: 26 Aug 2024 | QR700011883 PET Scan Controller X Invalid dose value. Please make sure that dose, date and time are correct. 350 Test, JOE OK 5 Isotope F-18 Pharm. Fluorodeoxyglucose Dose 0.00 mCi Date 06- Apr-2023 Time 13:01:42 Scan range Match CT Range 12 No. of beds 5 Scan duration= 3 min 7. Click Load and then click and hold the Move button. Onco_LowDose (Adult) Test, JOE Topogram Isotope F-18 SIEMENS CT LowDose Dose 10.00 + Pause Date 06-Apr PET Press MOVE Sca 3º No STOP Scar table and gantry Range: Begin End on Heig Load Cancel Recor -1644.0 855.5 1763.0 v 100 Routine Scan Recon Auto Task 8. You can manipulate the reconstruction parameters on the recon subtask card although there will be no effect on the simulated data. Click Start on the control box. Recon job 1 2 3 4 5 6 7 8 Series description PET AC Recon range Bed 1 7 Attenuation correction CT Output Image type Corrected AC CT 5.0 HD_FoV (1-1) Scatter Correction Recon method TrueX+TOF (ultraHD-PET) Relative Iterations 4 Subsets 5 Registration Matrices Default Image size 440 Zoom 1.0 Filter All-pass Offset (mm) × 0 Additional Settings Comments Routine Scan Recon Auto Tasking Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2023 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 14 of 21 SmartSimulator Workbook | MI PET VG80 Workbook Effective Date: 26 Aug 2024 | QR700011883 Onco_LowDose (Adult) Fest 788.2 mm 5 min 10 mC Topogram sotope F-18 SIEMENS CT LowDose Dose 10.00 Pause Date 22-May PET Press START Sce No stai 4.4 Range Begin End Height Scan direction Cancel -1644.0 -855 2136.5 125.0 Caudocranial 9. Once the PET acquisition has completed, the PET and CT datasets will load into the TrueD task card. Please note: There may be some screen flickering and slight delay before the data loads into the TrueD task card. This behavior is only seen on the simulator in the cloud environment. In addition, the PET data is from a phantom scan and is a limitation of the cloud simulator. 10. To close the patient in the Examination task card, click the Close Current Patient icon on the bottom left. E-logbook will then be displayed, and you can click OK to finally close. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2023 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 15 of 21 SmartSimulator Workbook | MI PET VG80 Workbook Effective Date: 26 Aug 2024 | QR700011883 Patent Applications PET Edt Insert View Setup Image Options System Help Test, JOE H Hospital Test, JOE Examination 12345 Biograph 1 28_Vision 600 Edge 12345 Biograph1 28_Vision 600 Edge "06-Apr-1968, M, 55Y VG80A "06-Apr-1968, M. H-SP 06-Apr-2023 VG80A 06-Apr-2023 H-SP.CR 13:42:30.43 13:50.06.00 1 IMA 3 IMA 1 TOP SP-750.5 AC 2001 SP-1641.5 Viewing 10cm Filming KV 120 MA 35 11 5.9 OT 0.0 1024 0/0 Tr60 1On. UOPO ., 11 LowDose AC CT 5.0 HD_FOV Onco_LowDose (Adult) Test, JOE 788.2 mm 50 sec 10 mCi 3D Topogram Isotope F-18 Pharm. Fluorodeoxyglucose CT LowDose Dose 10.00 mCi Pause Date 06- Apr-2023 Time 13:01:42 Simulation PET Scan range Match CT Range 2 No. of beds Scan duration sec TrueD Cose current patient Range: Begin End Table: Position Height Scan direction Load Hold 1644.0 .855.5 -1610.0 100 Recor Recor Caudocranial Routine Scan Recon Auto Tasking No. 1 Date of birth 01-Jan-1946 Pharmaceutical Fluorodeoxyglucose Date 16-Jul-2024 Scan protocol name Onco (Adult) Isotope F-18 Patient first name Total mAs 508 Inj. dose 10.00 mCi Patient last name Demo_Vision600_ ... PET scan length 261.65 Inj. time 06:30:39 Patient ID Anonymous Total PET scan time 00:00:03 Inj. date 20240716 OK Cancel Viewing Patient Data in TrueD Exercise: Load a Patient into TrueD In this exercise, you will learn how to load a patient into TrueD. 1. If you would like to manipulate actual patient data in the TrueD card, open the Patient Browser under the Patient dropdown. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2023 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 16 of 21 SmartSimulator Workbook | MI PET VG80 Workbook Effective Date: 26 Aug 2024 | QR700011883 Patient Applications PET Edit Insert View Setup Image Options System Help E-Logbook F12 ............................................................................................ Register ... Num 0 Browser Num Examination Feo Status Close Patient Filming Layout ... Film Task Status ... Film Preview ... Expose Film Task Ctrl+P 2. Select the AC CT and the PET series of any dataset. Click the Load to TrueD icon. You can now return to the TrueD task card to manipulate the data. Patient Browser Patient Applications Transfer Edit PET View Filter Evaluation Sort Options X Load To TrueD Demo_Vision600_Brain [4] CT 2.0 130f 3 iMAR Demo_Vision600 MBF [12] uhd_440_415s_0mm Local Database Demo_Vision600 WB_C_ PET 1_Pet_FDG_ [13] uhd_440_415s_0mm_of Scheduler HIGHRESTMBF1 PET 1 Pet FDG_Tronc Flow ONCOFREEZE_3min (Adult) HIGHRESTMBF3 [603] PET Frames Patlak_demo [602] PET Raw Data PulmNodules [2] AC CT 2.0 HD_FOV Test, JOE [1] Topogram 0.6 1801 WB_CBM_2 WB_Lung_1 3. The dataset will load into the TrueD tab. This is the 2x2 Combined layout. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2023 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 17 of 21 SmartSimulator Workbook | MI PET VG80 Workbook Effective Date: 26 Aug 2024 | QR700011883 Patient Applications PET Transfer Edit View Image Orientation VRT Type Quantification Tools Reports Options System Help Demo_Vision600_WB_CBM_OncoFr ... Examination Anonymous VG75 Biograph64_Vision 900 Demo_Vision600_WB_CBM_ Anoninous "01-Jon-1950 "01-Jan-1950 CT, Wednesday, June 13. 2018 F 13-Jun-2018 PTAC, Wednesday, June 13.2013 11:21:09 13-Jun-2018 11:22:40 MR CT HPR PT AC Viewing Baseline 50 % PET 50 % CT Volume Registration Filming F Visualization MIP COI Image No 336,337 SP F567.2 W 300 9: 110.396,337 SL: 2.000 131 300000 6By 3 0.00 SUY bw SL: 2 000 SPF507.2 1 4.32 SUY Demo_Vision600_WB_CBM_OncoFr ... Anonymous 01-Jan-1950 VG75A 13-Jun-2018 3D 11:21:09 FUSED MPR Simulation F/S 10 TrueD F Quantification CQ! CT.PT : 50/50 x Report SPF567.2 Fluorodeoxyglucose 300 1 4.92 SUV BW SL: 2.000 131 300000 MBq F/s 10 27-Jun-2024 05:37:28 4. You can change the layout to a 2x2 Fused layout to see all three orthogonal views. Select the Layout Gallery from the Common Tool Area. -O- -O- B Layout Gallery .. 5. Now click the 2x2 Fused layout. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2023 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 18 of 21 SmartSimulator Workbook | MI PET VG80 Workbook Effective Date: 26 Aug 2024 | QR700011883 TrueD: Layout Gallery One time-point Layouts 1x1 2×2 2x2 Fused HH 2X2 2×2 2×3 Combined Navigator 3x3 Stack 3x3 Stripe 6. This will change the layout to display all three orthogonal views. Patient Applications PET Transfer Edit View Image Orientation VRT Type Quantification Tools Reports Options System Help Demo_Vision600_WB_CB Demo_Vision600_WB_CB. Demo_Vision600_WB_CBM_ Examination Anonymous Anonymous Biograph64 "01-Jan-1850 "01-Jan-1850 VOTSA CT. Wednesday, June 13. 2010 13-Jun-2018 13-Jun-2018 PTAC. Wednesday, Are 12.2019 11:21:09 11:21:09 FUSED MPR FUSED MOR Viewing 50 % PET Balelre 50 % CT Volume Registration Filming F A Visualization CT.PT : 50/50 MIP Fluorodeckyglucose W 300 T 4 92 SUV bw CO C 40 B 0 00 SUV bw 131 300000 MEx2 SL 2.000 151 500000 Mog C 40 8 0 00 SUV EN PTAC. Wednesday, June 13.2018 SPF556 5 SP A140 7 Filming Demo_Vision600_WB_COM_Oncoft. Anonymous "01-Jan-1950 13-Jun-2018 3D 11:21:09 FUSED MPR Simulation F/S TrueD Quantification CTRT : 50/ 50 Report 300 T 492 SUV bw SP 0.0 40 8 000 SUV EM SL: 2.000 131 300006 MEXX 27-Jun-2024 05:40:46 7. You can now scroll through the images using your left mouse button while pushing the mouse forwards and backwards. On the Coronal view, find an image where the liver is fully visible. Check your SUV values to be sure the quantification Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2023 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 19 of 21 SmartSimulator Workbook | MI PET VG80 Workbook Effective Date: 26 Aug 2024 | QR700011883 is correct. In the Common Tool Area, select the Sphere VOI. -O- -O- -O- A B C S phere VOI Please note: Normal healthy liver Average SUV values are typically between 2.0 – 2.5. This is a great way of verifying quantification prior to the Physician reading. If normal healthy liver Average SUV values are way off, check that the user entered the dose and weight correctly for the patient. 8. Hover your mouse over the center of the healthy liver and click once with the left mouse button. This will drop a pre-defined 5 cm sphere VOI in that area. Verify your patient’s Average SUV. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2023 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 20 of 21 SmartSimulator Workbook | MI PET VG80 Workbook Effective Date: 26 Aug 2024 | QR700011883 Demo Vision 600 WD CD H nonymous 401-Jan-1950 YO75A 13-Jun-2018 11:21:09 FUSED MPR A CIPI: 50/50 SP A141.4 300-1 4.92 SUV bw SL 2.000 191 500000 M6a 40 B 0.00 SUY bw 9. Once you have completed reviewing your image data, you can close the patient using the Close Current Patient button in the bottom right corner of the display. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2023 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 21 of 21
- biograph vision
- biograph mct
- vision
- mct
- pet
- vg80