Measurements and Annotations - USA
This PDF provides an overview of the measurement and annotation tools that enable measuring distances, lengths and angles of relevant structures or adding annotations to images.
Target group: All users
Audio: No
Recommended to be viewed on the following devices: Laptop, desktop computer (sufficiently large display required)
SIEMENS Healthineers Measurements and Annotations 3D Healthineers Job Aid CIARTIC Move Template Effective Date: 10 Aug 2021 | HILS 2223 Job Aid Effective Date: 12 June 2024 | QR700009803 Published by Siemens Healthineers AG © Siemens Healthineers, 2024 Measurements and Annotations – SIEMENS Healthineers Table of Contents Introduction 3 2D Live Image Gallery Displaying the Evaluation Functions 4 Thor.Aorta_Cios Alpha CIARTIC Move 30x30 VA30 0071 07/12/2018 01/01/1937 13:15:17 Control Panel: General Steps in the Measure Annotate Menu 5 000 Calibration Object 10 Measure annotate X 1 Distance = 10.0 mm T Control Panel: Perform Calibration 11 Distance Angle Text Comment Control Panel: Distance Drawing Mode 12 Control Panel: Angle Drawing Mode 14 Distance 10 mm Control Panel: Annotate Images 15 Control Panel: Setting the Side Identification 18 Evaluation on the Monitor 20 Monitor: General Steps 21 Monitor: Perform Calibration 23 Monitor: Measure the Distance and Angle 24 Monitor: Annotate Images 25 Save Images During Postprocessing 27 2 Job Aid Effective Date: 12 June 2024 | QR700009803 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Measurements and Annotations – SIEMENS Healthineers Introduction With the measurement and annotation tools, you can 2D Live Image Gallery measure distances, lengths, and angles of relevant structures or add annotations to your images. Thor.Aorta_Cios Alpha CIARTIC Move 30x30_VA30_0071 07/12/2018 01/01/1937 13:15:17 000 During image evaluation, the layout automatically switches to 1x1 layout. When the evaluation is finished the original Measure annotate X 1 Distance = 10.0 mm monitor layout is restored. T Distance Angle Text Comment Graphical evaluations can only be performed on a single image at a time. The graphic objects are saved in the image automatically. Distance 10 mm Please note: Measurements are not possible for images imported from other modalities and images from external video sources (CAP images). 3 Job Aid Effective Date: 12 June 2024 | QR700009803 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Measurements and Annotations – SIEMENS Healthineers Displaying the Evaluation Functions The image evaluation tools can be accessed in two different ways. On the following slides, we will first look at how you use the evaluation functions via the control panel. From slide 20, you will learn more about the enhanced mouse mode. Measure Annotate Menu on Control Panel Evaluate images on the Monitor You can use one of the system's control panels (touch user interface). If you are working on the monitor trolley, you can perform all There you will find the evaluation tools within the Measure Annotate evaluation functions directly on the monitor with the mouse or finger. menu. You only use the control panel to enter text. Orb. 0º Set 1st Pointe X 2D point Ang.0º Positions Live Ref Measure annotate X uGym2 KV Calibrate Delete Phrase 1 14 80 selected Image T Gallery hh:mm:ss mAS Distance Angle Text Comment 00:00:04 1.3 [I] Free text R 3D T Collimator Laser Reset timer Distance Angle Text Delete all Panorama Fluoro Single Apps image 3D Scan R REC Distance Rotate Live graph Live Zoom Pan Measure Flip overlay recording Reset all 100.0 Shutter Annotate mm Sub Road DCM Brightness LA Transfer Hold Contrast reference Cine replay Previous Next Medium Auto Dose Metal correction Tech lock Image Print Export 976 × 976 enhance Store Store cine OPAC Mag 0 80.0 kV Mask#1 15 p/ 0.84 mAs LUT NAT 2 D: 0.000 LUT SUB 2 Magnify Motion Noise filter Pulse rate HOME Mag 0 Edge 1.00 Close pat. Keyboard 9: 60/60 C: 120 WW: 4095 Vask Adipos B: 3000 WC: 1600 4 Job Aid Effective Date: 12 June 2024 | QR700009803 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Measurements and Annotations – SIEMENS Healthineers Control Panel: General Steps in the Measure Annotate Menu Open the Measure Annotate Menu 3 Orb. 0º X 2D Set 1st Delete Positions point point 1. If the image that you want to evaluate is not yet Ang.0º Live Ref displayed in the 2D view on the monitor, single-select uGym2 KV Calibrate Delete Phrase 1 selected and open it from the Image Gallery. 14 80 Image Gallery hh:mm:ss mAs 2. Press the Measure Annotate button. 00:00:04 1.3 Free text L R 3D 3. The Measure Annotate menu is opened. T Collimator Laser Reset timer Distance Angle Text Delete all Panorama Fluoro Single 3D Apps image Scan R T Rotate Live graph Live Zoom Pan Measure Flip overlay recording Shutter Annotate Reset all Sub Road DCM Brightness Transfer Hold 2 Contrast reference Cine replay Previ Next Medium Auto Dose Metal correction Tech lock Image enhance Store Store cine Print Export Mag 0 15 p/s Magnify Motion Noise filter Pulse rate HOME Close pat. Keyboard 5 Job Aid Effective Date: 12 June 2024 | QR700009803 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Measurements and Annotations – SIEMENS Healthineers Control Panel: General Steps in the Measure Annotate Menu Move the Mouse Pointer Orb. 0º Set 1 st X 2D Delete point point Use the mouse pointer to set the position in the image where Ang.0º Positions Live Ref you want the processing of graphic objects to take place (such HGym2 kV Calibrate Delete Phrase 1 as insert, select). 14 80 selected Image Gallery hh:mm:ss mAs Use the arrow buttons to move the mouse pointer in the 00:00:04 1.3 Free text R 3D image. + T Collimator Laser Reset timer Distance Angle Text Delete all Panorama • Vertical arrow buttons: Move up/down Single 3D Apps • Horizontal arrow buttons: Move left/right Fluoro mage Scan R T Rotate Live graph Live Zoom Pan Measure Diagonal arrow buttons: Combined horizontal and vertical Flip overlay recording Shutter Annotate Reset all • movement Sub Road DCM REF Brightness Transfer Hold Contrast reference Cine replay Previous Next Medium Auto Dose Metal correction Tech lock Or – Image enhance Store Store cine Print Export – Mag 0 15 p/s Move the mouse pointer with the mouse on the monitor Magnify Motion Noise filter Pulse rate HOME Close pat. Keyboard trolley. 6 Job Aid Effective Date: 12 June 2024 | QR700009803 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Measurements and Annotations – SIEMENS Healthineers Control Panel: General Steps in the Measure Annotate Menu Select a Graphic Object Orb. 0º Set 1 st X 2D Delete point point To move, edit, or delete an existing graphic object, you must Ang.0º Positions Live Ref first select the object. HGym2 kV Calibrate Delete Phrase 1 14 80 selected Image To do that, move the mouse pointer with the arrow buttons or Gallery hh:mm:ss mAs the mouse on the monitor trolley to the graphic object. 00:00:04 1.3 Free text R 3D When an object is selected, the reference points (vertices, + T center point) are highlighted. Collimator Laser Reset timer Distance Angle Text Delete all Panorama Fluoro Single 3D Apps mage Scan R T Rotate Live graph Live Zoom Pan Measure 1 Distance = 10.0 mm Flip overlay recording Shutter Annotate Reset all Sub Road DCM REF Brightness Transfer Hold Contrast reference Cine replay Previous Next Medium Auto Dose Metal correction Tech lock Image enhance Store Store cine Print Export Mag 0 15 p/s Magnify Motion HOME Noise filter Pulse rate Close pat. Keyboard 7 Job Aid Effective Date: 12 June 2024 | QR700009803 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Measurements and Annotations – SIEMENS Healthineers Control Panel: General Steps in the Measure Annotate Menu 5 ........... Move a Graphic Object End line 1. Select the graphic object. 2 2. Press Set 1st point. The graphic object is linked to the Delete X Set 1 st 2D mouse pointer. Orb. 0º point point Ang.0º Positions Live Ref 3. Position the mouse pointer (+) to the desired starting uGym2 KV Calibrate Delete Phrase 1 position. 14 80 selected Image 6 Gallery hh:mm:ss mAs 4. Move the graphic object to the required position with the 00:00:04 1.3 Free text IR 3D arrow buttons or mouse. T Collimator Laser Reset timer Distance Angle Text Delete all Panorama 5. Press End line. The link between the graphic object and 1 + 4 the mouse pointer is removed. Fluoro Single 3D Apps image Scan R REC T Rotate Live graph Live Zoom Pan Measure 6. The Calibrate button can now be selected. The button is Flip overlay recording Shutter Annotate Reset all dimmed until you draw a line and is only highlighted if Sub Road DCM O. the + is over the line. Brightness Hold Contrast Transfer reference Cine replay Previous Next Medium Auto Dose Metal correction Tech lock Image enhance Store Store cine Print Export Mag 0 15 p/s Magnify Motion Noise filter Pulse rate HOME Close pat. Keyboard 8 Job Aid Effective Date: 12 June 2024 | QR700009803 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Measurements and Annotations – SIEMENS Healthineers Control Panel: General Steps in the Measure Annotate Menu Delete Selected Graphic Objects Delete All Graphic Objects 1. Select the graphic object. Press Delete all. 2. Press Delete selected. All graphic objects in the image are deleted. The selected graphic object is deleted. X X Set 1 st Delete Set 1st Delete point point point point Calibrate Delete Phrase1 selected Calibrate Delete Phrase 1 selected Free text L R Free text L R T T Distance Angle Text Delete all Distance Angle Text Delete all 9 Job Aid Effective Date: 12 June 2024 | QR700009803 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Measurements and Annotations – SIEMENS Healthineers Calibration Object If you perform evaluations with distance measurements, you must 2D Live Image Gallery calibrate the image. Thor.Aorta_Cios Alpha CIARTIC Move 30x30 VA30 0071 For a calibration to be performed, there must be a calibration object 01/01/1937 07/12/2018 13:15:17 000 in the image. For increased accuracy, it is recommended to use a calibration object that is as large as possible, but still can be displayed completely. The edges of the calibration object must be clearly recognizable, and its dimensions must be known. Please note: The calibrating accuracy decreases if the calibration object is not located in the same plane as the measured object. 976 × 976 OPAC 80.0 kV Mask#1 0.84 mAs LUT NAT 2 D: 0.000 LUT SUB 2 Mag 0 Edge 1.00 9: 60/60 C: 120 WW: 4095 Vask Adipös B: 3000 WC: 1600 10 Job Aid Effective Date: 12 June 2024 | QR700009803 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Measurements and Annotations – SIEMENS Healthineers Control Panel: Perform Calibration Perform Calibration X Set 1st Delete 1. First, draw a distance line along the calibration object. point point Press the Line button to activate distance drawing mode. Be careful to mark the starting and end points 2 Calibrate Delete Phrase 1 with as close to pixel accuracy as possible in order to selected achieve optimal measuring accuracy. For more information regarding distance drawing Free text L R mode, please see the next slide. 2. When your line is complete, press Calibrate. T The control panel switches to keyboard mode. 1 Distance Angle Text Delete all 3. Enter the distance (mm) and confirm with Enter. A length scale is displayed in the image and is applied to the remaining images of the series. Distances already drawn in are updated. 11 Job Aid Effective Date: 12 June 2024 | QR700009803 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Measurements and Annotations – SIEMENS Healthineers Control Panel: Distance Drawing Mode Using a distance line, you can measure the distance between two points in an image. 3 ......... End line 1. Press the Line button to activate the Distance drawing mode. 2. Use the arrow buttons to move the mouse pointer to the starting point of the line, and press Set 1st point. 2 X Set 1 st Delete point point Or click the starting point with the left mouse button. The button changes to Set last point. Calibrate Delete Phrase 1 selected 3. Use the arrow buttons to move the mouse pointer to the last point of the line and press End line. Or click the last point with the left mouse button. Free text L R The length (mm) and the sequential number of the graphic T object are displayed at the end point of the line. 1 Distance Angle Text Delete all 12 Job Aid Effective Date: 12 June 2024 | QR700009803 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Measurements and Annotations – SIEMENS Healthineers Control Panel: Distance Drawing Mode Delete Points X Set 1st Delete If the starting point or end point has been placed incorrectly, it can be point point deleted immediately after being drawn. 1. To delete a point, select Delete point. The last point set is deleted Calibrate Delete Phrase 1 selected from the image. 2. If the starting point is deleted, add a new starting point by L pressing Set 1st point to draw the line again. Free text R T Distance Angle Text Delete all 13 Job Aid Effective Date: 12 June 2024 | QR700009803 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Measurements and Annotations – SIEMENS Healthineers Control Panel: Angle Drawing Mode You can define an angle of two lines by drawing the legs of the angle .......... on the image. 3 End line 1. Press the Angle button to activate the Angle drawing mode. 2. Draw the first line in the image by setting the starting point and end point. 2 X Set 1 st Delete point point 3. Draw the next line in the image by setting the starting point and end point. Calibrate Delete Phrase 1 selected Now, the angle is set. The drawn angle (in °) and the sequential number of the graphic object are displayed at the end points of the legs. Either an inner or outer angle is indicated depending on the Free text L R starting point and end point of the second leg. 1 4 T Distance Angle Text Delete all 14 Job Aid Effective Date: 12 June 2024 | QR700009803 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Measurements and Annotations – SIEMENS Healthineers Control Panel: Annotate Images Enter Free Text X You can annotate interesting or anomalous areas in the image by entering 2 Set 1st Delete point point free text. Calibrate Delete Phrase 1 1. Press the Text button to activate the Text drawing mode. selected 2. Move the mouse pointer to the required position for the annotation 3 with the arrow buttons or mouse. Free text L R 3. Press the Free text button. The control panel switches to keyboard T mode. Distance Angle Text 1 Delete all 4. Enter the text and confirm with Enter on the keyboard. The text is inserted at the position of the mouse pointer. X ESC F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 1 2 4 5 6 Back CO O space W 4 Tab W e t U p O - - Caps Lock d If g Th k Shift 2 b n m Enter Ctrl Alt 15 Job Aid Effective Date: 12 June 2024 | QR700009803 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Measurements and Annotations – SIEMENS Healthineers Control Panel: Annotate Images Insert Predefined Text X Set 1st Delete Frequently used texts can simply be selected from a template once they point point have been created as such. The predefined texts are created on the monitor trolley (please refer to page 26 Creating and deleting predefined texts for Calibrate Delete Phrase 1 more information). selected Select the required text from the selection list. The text is inserted at the Phrase 1 position of the mouse pointer. R My note Distance Angle Delete all Pelvis RIA REC 15 Rotate Live graph Live Flip overlay recording Reset all Test phrase REF Brightness Contrast Transfer Hold reference Next Image enhance Store Export HOME Close pat. Keyboard 26 Job Aid Effective Date: 12 June 2024 | QR700009803 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Measurements and Annotations – SIEMENS Healthineers Control Panel: Annotate Images Change Text X 1. Select the graphic object with the text. Set 1 st Delete point point 2. Press the Free text button to change the text using the keyboard. Calibrate Delete Phrase 1 selected Or – – Select a new text from the selection list. Free text L R T Distance Angle Text Delete all 17 Job Aid Effective Date: 12 June 2024 | QR700009803 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Measurements and Annotations – SIEMENS Healthineers Control Panel: Setting the Side Identification Add Side Identification 2 X By identifying the side of the patient, you avoid a mistake in image Set 1 st Delete point point orientation. The side identification is applied automatically to the remaining images of the series. Calibrate Delete Phrase 1 selected 1. Switch on the Text drawing mode, if required. R 2. Move the mouse pointer to the required position for the identification (such as the edge of the image) using the arrow Free text L R 3 buttons on the control panel or the mouse on the monitor 4 T trolley. Distance Angle Text Delete all 3. Press the button for the correct patient side. The selected identification L or R is inserted at the position of the mouse 1 pointer. 18 Job Aid Effective Date: 12 June 2024 | QR700009803 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Measurements and Annotations – SIEMENS Healthineers Control Panel: Setting the Side Identification Change Side Identification X Press the L or R button for the correct patient side. Set 1st Delete point point The original side identification is deleted. The selected identification L or R is inserted at the position of Calibrate Delete Phrase 1 selected the mouse pointer. R Free text L R T Distance Angle Text Delete all 19 Job Aid Effective Date: 12 June 2024 | QR700009803 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Measurements and Annotations – SIEMENS Healthineers Evaluation on the Monitor 2 Measure annotate X L T Distance Angle Text Comment Activating Evaluation on the Monitor HH 1. Select this button on the monitor. Distance 10 The Measure annotate menu is displayed on the monitor. mm 2. Select the button for the required function. The control panel switches to keyboard mode. Turning off Enhanced Mouse Mode Click the button of the activated function. X Or end keyboard mode on the control panel by selecting the X. 976 × 976 OPAC 80.0 kV Mask#1 0.84 mAs LUT NAT 2 D: 0.000 LUT SUB 2 Mag 0 1 Edge 1.00 9: 60/60 C: 120 WW: 4095 Vask Adipos B: 3000 WC: 1600 20 Job Aid Effective Date: 12 June 2024 | QR700009803 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Measurements and Annotations – SIEMENS Healthineers Monitor: General Steps Selecting an Object, Moving an Object and 30x30_VA30 0071 12/2018 01/01/1937 07012 3:15:17 000 Changing Dimensions You must select an existing graphic object to process it. 1. Click the Selection button. 2. Select the graphic object. To move the graphic object, press the left mouse button, and drag and drop the center point to the required position. To change the dimensions of the graphic object, press the left mouse button and drag & drop the vertices in the required direction. Measure annotate X Measure annotate X T Distance Angle Text Comment T Distance Angle Text Comment Comment Add to ... Delete f ... 976 × 976 OPAC 80.0 KV Mask#t1 1 21 Job Aid Effective Date: 12 June 2024 | QR700009803 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Measurements and Annotations – SIEMENS Monitor: General Steps Healthineers Delete Selected Graphic Objects Delete All Graphic Objects 1. To delete individual graphic objects, select the graphic object. To delete all graphic objects in the image, select the highlighted button 2. Press the Backspace button on the control panel to delete the on the left image area. selected object or select the single trash can icon. Measure annotate X E × T ESC F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 Distance Angle Text Comment 1 2 4 5 6 8 9 Back = W space O Tab W e t b y u O p . 1 Caps Lock a S d If 9 h k - Shift Z X C V b n m Enter Ctrl Alt 22 Job Aid Effective Date: 12 June 2024 | QR700009803 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Measurements and Annotations – SIEMENS Healthineers Monitor: Perform Calibration 1. Draw a distance line (see following page) along the calibration object and select it. Measure 1 te X 2. Enter the distance in arbitrary units (e.g. in mm) and select T OK. A length scale is displayed in the image and is applied to Distance Angle Text Comment the remaining images of the series. Distances already drawn in are updated. Thor.Aorta_Cios Alpha CIARTIC Move Please note: The current calibration cannot be deleted or stored. 30x30 A30 0071 07/12/2018 01/01/1 37 13:15:17 You can only overwrite the current calibration by setting up a new 000 calibration. Measure annotate X 1 Distance = 10.0 mm T Distance Angle Text Comment Distance 10 mm 2 23 Job Aid Effective Date: 12 June 2024 | QR700009803 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Measurements and Annotations – SIEMENS Healthineers Monitor: Measure the Distance and Angle Measuring the Distance 1. Select the Line button. 2. In the image, select the starting point of the line and the desired end point to complete the distance line. Measure annotate × Measuring an Angle T 1. Select the Angle button. 2. Draw the first line in the image by setting the starting point and end point. Distance Angle Text Comment 3. Repeat the process for the second line to complete the angle. 24 Job Aid Effective Date: 12 June 2024 | QR700009803 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Measurements and Annotations – SIEMENS Healthineers Monitor: Annotate Images To add annotations, do the following: 1 X 1. Select the Text button. The input dialog box for text is displayed. Measure annotate 2. To set the side identification, select the appropriate patient side in the dialog box and the appropriate location in the image. T 4 3. To insert annotations, select the annotation from the Text selection Distance Angle Text Comment list. You can also select the text field of the Text selection list and overwrite the displayed text. Then click the required position in the image. 4. To add a comment, select the text from the Comment selection list. Or click the text field of the Comment selection list and overwrite the 2 L R displayed text. Comments always appear centered at the bottom edge of the image and are transferred automatically to all images of the series. 3 Text goes here Text1 Add to ... Delete f ... 25 Job Aid Effective Date: 12 June 2024 | QR700009803 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Measurements and Annotations – SIEMENS Healthineers Monitor: Annotate Images Creating and Deleting Predefined Texts Measure annotate You can save frequently used texts and comments as templates and X select them from the list as needed. 1. To create a predefined text, enter the text in the text field of the T corresponding selection list. Distance Angle Text Comment 2. Click the Add to... button. The text is added to the list as a new entry. Up to 20 entries each can be created in the Text and Comment selection lists. 3. To delete a predefined text from the selection list, select the entry you no longer require. Then, click the Delete f... button. Text goes here 1 Text 1 2 Add to ... Delete f ... 3 26 Job Aid Effective Date: 12 June 2024 | QR700009803 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Measurements and Annotations – SIEMENS Healthineers Save Images During Postprocessing After completing postprocessing of a prior examination, all changes in the image are saved when you close the Orb. 0º X Set 1st Delete 2D point point patient. To close a patient, select the Close pat. button. Ang.0º Positions Live Ref If you want to save intermediate states, manually save the uGym2 KV Calibrate Delete Phrase 1 selected Image image in the required processing phase. The image is 14 80 Gallery saved as a copy of the original in the corresponding study. hh:mm:ss mAs 00:00:04 1.3 [III Free text L R 3D Press the Store button on the control panel to save a copy T of the displayed image with its changes. Collimator Laser Reset timer Distance Angle Text Panorama Delete all Fluoro Single 3D image Scan 15 Apps R REC T Rotate Live graph Live Zoom Pan Measure Flip overlay recording Shutter Annotate Reset all Sub Road DCM Brightness Transfer Hold Contrast reference Cine replay Previous Next Medium Auto Dose Metal correction Tech lock Image enhance Store Store cine Print Export Mag 0 15 p/s Magnify Motion HOME Noise filter Pulse rate Close pat. Keyboard 27 Job Aid Effective Date: 12 June 2024 | QR700009803 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 SIEMENS Healthineers Please note this learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Siemens Healthineers HQ I Siemens Healthineers AG Siemensstr. 3 91301 Forchheim Germany Phone: +49 9191 18-0 siemens-healthineers.com 28 Job Aid Effective Date: 12 June 2024 | QR700009803 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024
- ciartic
- cios
- move
- ciarticmove
- c-arm
- annotate
- measure