Siemens Healthineers Academy
Manual Gradient Mode

Manual Gradient Mode

The job aid provides an overview of Manual Gradient Mode.
Target group: All users
Recommended to be viewed on the following devices: All (incl. tablet, smartphone)

SIEMENS Healthineers Manual Gradient Mode Job Aid Template Effective Date: 10 Aug 2021 | HILS 2223 Effective 15 Jan 2024| QR700004487 Unrestricted I Published by Siemens Healthineers AG I © Siemens Healthineers, 2024 Manual Gradient Mode SIEMENS Healthineers Table of contents How to use it 3 RF Pulse Type Normal How to ensure suitable performance 5 Image examples What can you do with the DICOM files? 6 5 Gradient Mode Manual Ed ... How can you activate it? 6 Flow Compensation Interactive mode - Screen layout 8 Fast Performance Interactive mode - Workflow steps 9 Boost Manual Interactive mode - Tools bar 15 PACS Ready mode 17 How to ensure suitable performance? 19 Saving the Results 15 PACS Ready Mode 16 How to ensure suitable performance 17 2 Effective Date: 15 Jan 2024| QR700004487 Unrestricted I Published by Siemens Healthineers AG I © Siemens Healthineers, 2024 Manual Gradient Mode SIEMENS Healthineers How to use it You can use Manual Gradient Mode to enhance protocol performance and make full use of the gradient system. You can find it in Protocol Parameters > Sequence > Part 1. Protocol Parameters Routine Contrast Resolution Geometry System Physio Inline Sequence Voice Commands Execution Part 1 Part 2 Assistant Image Management Sequence Name tse Bandwidth 252 - Hz/Px Auto Load Dimension 2D Echo Spacing 8.30 % ms Copy References RF Pulse Type Normal Define Turbo Factor Turbo Factor 5 + Gradient Mode Manual Echo Trains per Slice 64 Flow Compensation None 3 Effective Date: 15 Jan 2024| QR700004487 Unrestricted I Published by Siemens Healthineers AG I © Siemens Healthineers, 2024 Manual Gradient Mode SIEMENS Healthineers How to use it 1. To activate it, select Manual from the drop-down menu. RF Pulse Type Normal 2. Click on the three dots next to the drop-down menu to Gradient Mode Manual Ed adjust the Max. Gradient Amplitude and the Min. Gradient Rise Time that is applied to the sequence. By Flow Compensation Fast default, the rise time is set at the system minimum and the Performance maximum gradient amplitude is set at the maximum. Boost Manual Gradient Mode Settings X Min. Gradient Rise Time 5.00 + us/(mT/m) Max. Gradient Amplitude 80.00 - mT/m 80.00 Max. Gradient A ... 14.80 191.00 mT/m 80.00 Close 4 Effective Date: 15 Jan 2024| QR700004487 Unrestricted I Published by Siemens Healthineers AG I © Siemens Healthineers, 2024 Manual Gradient Mode SIEMENS Healthineers How to ensure suitable performance Higher amplitudes / lower rise times will not always Routine Contrast Resolution Geometry System Physio Inline Sequence • Part 1 Part 2 Assistant lead to improved protocol performance. Manual Sequence Name fi Bandwidth 340 + Hz/Px Gradient Mode offers many possible amplitude / rise Scan Assistant ? x time combinations. For complex sequences it may be hetric Echo Allowed necessary to find the sweet spot of best protocol ? Your last change Gradient Mode Fast -+ Manual performance. For example: will adapt the following parameters: Gr TR 7.5 -+ 7.9 ms Manual mode can prolong minimum repetition time Flow Co OK Undo Segments • (TR) as the gradients ramp up to full amplitude, which takes longer. • Some gradients have their own limits or are coupled to the gradient mode limits with a specific factor. This means that not all gradients and all sequences might respond equally to the changes in the gradient limits that can be made in Manual mode. 5 Effective Date: 15 Jan 2024| QR700004487 Unrestricted I Published by Siemens Healthineers AG I © Siemens Healthineers, 2024 Manual Gradient Mode SIEMENS Healthineers Image examples AR K A Ultraflex elbow Ultraflex elbow Sequence Name tseBN Bandwidth 407 - Hz/Px 2023.03.06-10:21:05-STD-1.3.12.2.1107.5.99.3 MAGNETOM Cima.X 2023.03.06-10:21:05-STD-1.3.12.2.1107.5.99.3 MAGNETOM Cima.X *1/1/1999, F, 24Y MR XA61 *1/1/1999, F, 24Y MR XA61 3/6/2023 FFS 3/6/2023 FFS Echo Spacing 8.92 +LPH +LPH ms pd_tse_tra_272 latest pd_blade_tra_256 latest STUDY ID c635e972-44ba-48 STUDY ID c635e972-44ba-48 10:25:43 AM 10:35:57 AM 5 IMA 1 FRM 9/20 10 IMA 1 FRM 8/15 RF Pulse Type Low SAR RP R 20 2D Turbo Factor SL 00 3.3 SPC F Gradient Mode Performance . . . . . . . . . . . . . . . . . . . . . . . . .. ... Fast TR 2200.0 E TR 2000.0 TP H TE 44.0 TP H49 TE 32.0 performance Flow Compensation TA 01:47 SP H48. FoV 100*100 TA 02:16 SP H48.6 None FoV 90*90 BWV zoU.U 190*272 256*256 p2 MAGN NORM DIS2D Tra p2 MAGN/NORM/DIS2D Tra Reordering Linear EPI Factor A2/SAT1 Zoom 2.00 A1 Zoom 2.13 UFL W 1781 UFL W 1673 *tseR2d1rr7 / 136 Not for diagnostic use C 789 *tseBN2d1_7 / 150 Not for diagnostic use C 625 Not for diagnostic use IL Not for diagnostic use AR A Ultraflex elbow Ultraflex elbow 2023.03.06-10:21:05-STD-1.3.12.2.1107.5.99.3 MAGNETOM Cima.X 2023.03.06-10:21:05-STD-1.3.12.2.1107.5.99.3 MAGNETOM Cima.X Sequence Name tseBN Bandwidth 407 - Hz/PX *1/1/1999, F, 24Y MR XA61 *1/1/1999, F, 24Y MR XA61 3/6/2023 FFS 3/6/2023 FFS +LPH +LPH pd_tse_tra_272_Manual Echo Spacing 8.16 ms latest pd_blade_tra_256 Manual latest STUDY ID c635e972-44ba-48 STUDY ID c635e972-44ba-48 10:33:12 AM 10:38:13 AM 8 IMA 1 FRM 9/20 11 IMA 1 FRM 8/15 RF Pulse Type Low SAR RP R 2D 2D SL 22 Turbo Factor 18 + SL SPC 3.3 SPC F Gradient Mode Manual Manual TR 2200.0 TP H 3 TR 2000.0 TE 37.0 TP H49 TE 28.0 SP H48.6 TA 01:47 SP H48 TA 02:16 Flow Compensation None BVV 250.0 FoV 100*100 190*272 BW 391.0 FoV 90*90 256*256 p2 MAGN NORM DIS2D Tra p2 MAGN/NORM/DIS2D Tra A2/SAT1 Zoom 2.00 A1 Zoom 2.13 Reordering Linear EPI Factor UFL W 1806 UFL W 1673 *tseR2d1rr7 / 129 Not for diagnostic use C 802 *tseBN2d1_7 / 150 lot for diagnostic use Not for diagnostic use Not for diagnostic use 6 Effective Date: 15 Jan 2024| QR700004487 Unrestricted I Published by Siemens Healthineers AG I © Siemens Healthineers, 2024 SIEMENS Healthineers Please note this learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. © Siemens Healthineers AG 2024 Siemens Healthineers Headquarters Siemens Healthineers AG Siemensstr. 3 91301 Forchheim, Germany Telephone: +49 9191 18-0 siemens-healthineers.com 7 Effective Date: 15 Jan 2024| QR700004487 Unrestricted I Published by Siemens Healthineers AG I © Siemens Healthineers, 2024

  • gradient mode manual
  • manual cima
  • manual cima.x
  • gradient mode