MAMMOMAT B.brilliant system messages
This job aid will assist MAMMOMAT B.brilliant users on the different messages that may appear during a workflow and how to appropriately respond to these messages.
System Messages MAMMOMAT B.brilliant Start Up Messages System is not ready to How to respond: expose Perform a warm-up WH AWS This message will be generated 1. Lay the service steel The Mammo Unit has encountered a when the system has not plate on the detector to hardware related problem reached a workable protect the detector (ER#13-54-117-0). temperature. from ghosting The Mammo Unit will be reset. 2. Perform at least 4 expo- sures at any PV type *Standard 2D OK *200 mAs at 27 kV AEC Messages Mammo Unit timeout for How to respond: AEC dose VH AWS This message will be generated Avoid using “Ready Exposure aborted after prepuls, mAs when the system aborts an Workflow”. calculation failed. exposure because of an AEC 1. Once you have the pa- timeout. This message is tied to tient compressed, do the use of the ready not button to initiate exposure. engage the Ready But- ton for “ready to ex- OK pose feature”. 2. Go directly to the con- trol panel and expose. Unrestricted | Published by Siemens Healthineers AG, 2024 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 6/4/2025 | QR700024152 Healthineers Ready Button Messages Exposure workflow is How to respond: interrupted TH AWS This message will be generated 1. Wait for the tube The connection to the Mammomat is down. when the exposure button is head to reach the Please check the cables. Patient registration and image acquisition is pressed before the tube has scan position and not possible until the problem is solved. reached the scan position. ensure the green exposure light is OK *May see these messages illuminated on the independently or in combination. control panel before starting exposure. Usolicited image(s) had to be retrieved from the detector. The detector system will 2. If the system allows, be automatically reset to resolve the problem. Please create a Savelog and continue with the contact Service. exam. 3. If unable to activate OK the next projection WH AWS view, create a save log and contact the The previous acquisition has crashed. The MammoUnit returned the following Customer Care parameters: kV: 26. mAs: 4.0, Anode/Filter: W/AI1.0, Glandular dose: 0.0, Angle: -49.0, Center. Compression thickness: 46, Compression force: 45.4. OK Unrestricted | Published by Siemens Healthineers AG, 2024 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 6/4/2025 | QR700024152 Healthineers Page 2 of 4 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthineers AG 2025 Siemens Healthineers Headquarters Siemens Healthineers Headquarters Local Contact Information Local Contact Information Legal Manufacturer Legal Manufacturer Siemens Healthineers AG Siemens Healthineers AG Siemens Medical Solutions USA, Inc. Siemens Medical Solutions USA, Inc. Siemensstrasse 1 Siemens Medical Solutions USA, Inc. Siemensstraße 3 Siemensstraße 3 40 Liberty Blvd. 40 Liberty Blvd. Forchheim, Germany 91301 Molecular Imaging 91301 Forcheim, Germany 91301 Forcheim, Germany Malvern, PA, USA 19355-9998 Malvern, PA 19355-9998 USA 2501 N. Barrington Road Phone: +49 9131 84-4746 Phone: +49 9191 18-0 Phone: +49 9191 18-0 Telephone: +1-888-826-9702 Telephone: +1-888-826-9702 siemens-healthineers .com/radiography Hoffman Estates, IL 60192 USA siemens-healthineers.com siemens-healthineers.com siemens-healthineers .com/en-us Customer Care Telephone: Telephone: +1 847 304-7700 +1-800-888-7436 siemens-healthineers.com/molecular-imaging Unrestricted | Published by Siemens Healthineers AG, 2024 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 6/4/2025 | QR700024152 Healthineers Page 3 of 4 Unrestricted | Published by Siemens Healthineers AG, 2024 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 6/4/2025 | QR700024152 Healthineers Page 4 of 4
- messages