MAMMOMAT B.brilliant Superuser Quick Guide
This quick guide will cover superuser tasks on your MAMMOMAT B.brilliant. The following job aids
provide steps to navigate advanced functions on your system.
MAMMOMAT B.brilliant Superuser Le SIEMENS Quick Guide MAMMOMAT B.brilliant Welcome to Siemens Healthineers This quick guide will cover superuser tasks on your MAMMOMAT B.brilliant. The following job aids provide steps to navigate advanced functions on your system. SIEMENS Healthineers Table of contents How to add a new tomo procedure 3 How to add a combined procedure 5 How to locate the system software 7 How to perform a patient search 8 How to check your detector temperature 9 How to add and configure new users 12 How to Add A New Superuser Quick Guide I MAMMOMAT B.brilliant Tomo Procedure How to add a new tomo procedure MAMMOMAT B.brilliant 1. From the top dropdown menu, select Options>Configuration. Options Help Maintenance End Session Auto Enable First PV Configuration Service Security 2. Double-click on Procedure Handling Configuration. Procedure Handling Configuration 3. Highlight the appropriate type of exam and select Copy (i.e., Tomo Bilateral). 4. Remove the copied Tomo+Bilateral, and retype the RIS procedure with Copy of in the de- scriptor (i.e., Copy of MMBilateral Tomosynthesis) Procedure Handling Configuration Procedures EXPOSL I ist of Procedures 1- QC-raw PHANTOM 1- QC-raw ARTIFACT DETEC * 1- QC-raw DET UNIFORMITY 1QC-processed TOMO PHAN Procedure details • Select exam purpose (screening or diagnostic). Mammogram - bilateral - Stan Name Copy of MMBILATERAL TOMOSYNTHESIS TiCEM - bilateral Examination purpose Screening TiCEM right • Store procedure as: TiCEM - loft Store procedure as Mammogram : Mag - bilatera Show Procedure Code Available for all user – If you are using a Mammogram + Spot - bilatera o Mammogram - right - Standar Marrimogram - left - Standard Auto Decomp Opcomp Unprocessed single login Magnification - bilateral Spot - bilateral Exposure Program ser o Current user only – If you have multiple Implant - bilateral Implant + Implant displaced - b Defaut Display Layout Constancy Test QC-raw Autofilming Autoexpose Slop InExam Transfer logins. Calibration QC-processed P Set • Check the box for Auto Decomp, Opcomp, Skip InExam IQ Display Markers Biopsy Calibration Transfer. Biopsy I eft - Stereo Biopsy Right - Stereo Biopsy Left Tomo + Stereo • Default Display Layout 1:1 Biopsy Right Tomo + Stereo Biopsy Loft 2D + Tomo + Ster Biopsy Right 2D . Tomo i Ste Tomo - hillateral Tomo + 2D Standard - bilatera DITIO + 2D PRIME - bilateral • Make sure the box is checked next to On_raww Tomo the newly created procedure. NOW CONY Delete Set default OK Cancel Apply 5. Select Apply. 6. Select Modify PVS. Modify PVS Unrestricted | Published by Siemens Healthineers AG, 2024 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 12/27/2024 | QR700017361 3 Superuser Quick Guide I MAMMOMAT B.brilliant 7. If the PVS displayed (in the Current Projection View Set) is not the correct workflow, dou- ble-click on each icon to delete them. 8. Select the appropriate Acquisition mode- TOMO for the views you add. Select any modifi- ers if needed. 9. Double-click from the selection of PVS (i.e., LCC,RCC, RML, LMO). PVS Dialog Modify PVS Modily PV soque Current Projection View sat R-CC L-DC R-MLO L-MLO Acquisition mode Axtary Tal Implant Displaced " Tangential Rolled inferior Rolled Lateral @ Robied Medial T Rolled Superior Magrinca L-SPEC R SPEC LEO L-XCC Q-xCC R-MLO LIM L-ICCL H-XCCL B-IM LIMO L-XCCM R-XCCM R-LMO R-CC LFB R.FB OK Cancel ED 10. Select OK. 11. Select Apply to populate the procedure. 12. Select OK to close the box. 13. If additional users are configured on the system, you must log in as each user and perform the following steps. a) Follow steps 1 and 2. b) Highlight the newly created procedure titled (i.e., Copy of “MM Bilateral Tomo- synthesis”). Remove the Copy of from the procedure descriptor. c) Select Store procedure as and select current user only. d) Select Apply or follow steps 5 and 6 if the user's workflow is different from the dis- played option. Unrestricted | Published by Siemens Healthineers AG, 2024 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 12/27/2024 | QR700017361 Page 2 of 3 4 How to add a Superuser Quick Guide I MAMMOMAT B.brilliant Combined Procedure How to add a combined procedure MAMMOMAT B.brilliant 1. From the top dropdown menu, select Options > Configuration. End Session ... PLIPV 2. Double-click on Procedure Handling Configuration. Procedure Handling Configuration 3. Highlight the appropriate type of exam and select Copy (i.e., Tomo +2D Prime-Bilateral)). Remove the copied Tomo +2D Prime-bilateral and retype the RIS procedure with “Copy of” in the descriptor (i.e., Copy of MM Bilateral Tomosynthesis) edure Handling Configuration EXPOSU I ist of Procedures 1- QC-raw PHANTOM 1- QC-raw ARTFACT CE 1- QC-raw DET UNIFORN [Copy of MME LATERAL TOMOSYNTHES Screening • Select exam purpose (screening or diagnostic). 1QC processed TOMO P Mammogram - bilateral- Examinados purpose TICEM- bilateral TiCEM- right Store procedure as Store procedure as: TiCEM - left • Mammogram + Mag - bile Show Procedure Cod Mammogram + Spot - bile Mernogrern - right - Ster | Opcomp o Available for all users – If you are using a sin- Memmogrem - left - Stand Magnification - bilateral Exposure Program set 5pct - bilateral gle login Triplart - biletetal Doutait Display Layout Implart + Implant dispiace Constancy Test Autotiming QC-raw o Current user only – If you have multiple Caibration QC processed Display Maiers logins. Bicpsy Calibration Bicpsy Left - Stereo Bicpsy Right - Stereo • Check the box for Auto Decomp, Opcomp, Skip InExam Biopsy Left Toma + Stereo Bicpsy Right Temo + Stereo Biopsy Left 2D + Torno + Ster Transfer. Bicpsy Right 2D + Tomo + Ste Tomo - bilateral mo + 2D PRIME - bilaterel New Copy Make sure the box is checked next to • Delete Set defeut. the newly created procedure. OK Cancal APPY 4. Select Apply. 5. Select Modify PVS. Modify PVS Unrestricted | Published by Siemens Healthineers AG, 2024 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 12/27/2024 | QR700017361 5 Superuser Quick Guide I MAMMOMAT B.brilliant 6. If the current projection view set does not have the correct projection views, double-click each icon to delete them. Projection View set R-CC PRIME 2 R-CC TOMO L-CC PRIME L-CC TOMO R-MLO PRIME R-MLO TOMO L-MLO PRIME L-MLO TOMO 7. Select the appropriate Acquisition mode (i.e., PRIME PV and Tomo PV) for the view you want to add. 8. Select any modifiers, if needed, and double-click from the bottom selection of projection views. (i.e., LCC, RCC, RMLO, LMLO) 9. Select OK. 10. Select Apply to populate the procedure. 11. Select OK to close the box. 12. If additional users are configured on the system, you must log in as each user and perform the following steps. a. Follow steps 1 and 2 as described. b. Highlight the newly created procedure (i.e., Copy of “MM Bilateral Tomosynthe- sis”). Remove the Copy of from the procedure descriptor. c. For Store procedure as, select Current user only. d. Select Apply or follow steps 5 and 6 if the user’s workflow differs from the dis- played option. Unrestricted | Published by Siemens Healthineers AG, 2024 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 12/27/2024 | QR700017361 Page 2 of 3 6 How to Locate the Superuser Quick Guide I MAMMOMAT B.brilliant System Software How to locate the system software MAMMOMAT B.brilliant 1. Click Options>Service>Local Service from the top menu bar. 2. On the service software page, select OK. (the spaces for the service key will be empty). @ Siemens Healthcare Service Software - Intornot Explorer provided by Siemens Healthcare SIEMENS Service Software TC W//S8T39-VBKAJI Cary MAMMOMAT_B.brilliant VA10C MG 1038 WH AWS VF10B SL43P44 syngo VZ25A SL04P06 VA10C Please enter Service Key OK Upload / Enter new Service Key "The Service Software" you are trying to access is protected by copyrights and may only be used by authorized users within the scope of the authorization. We reserve all our rights in the event of any unauthorized use of the Software. Authorization can be acquired by entering into a royalty-bearing Software license agreement with Siemens. If you wish to enter into a licence agreement allowing services to be performed on this system under use of the Software, please contact your local Siemens Service Organisation for further information. In case you have questions, please contact your local Siemens Service Organisation for further information. 3. Click on Acquisition System. Siemens Hoalthcaro Service Software - Internet Explorer provided by Siemons Healthcare SIEMENS lome Men Senice Key Expiry Date: 28254303 Service LogBook Event Log Reports Logout Service Software - Siemens Expert TC WS8T39-VBKAJ Cary MAMMOMAT_B.brilliant VA10C MG 1038 WH AWS VF10B SL43P44 syngo VZ25A SL04P06 VA10C Device Guard Disabled Configuration DICOM Tests Backup & Restore Acquisition System waroDistribution 4. Click on System Service Information, and the System version is displayed. Acquisition System General Siemens Medical Solutions - Womens Health System Service Information Extract Savelogs Autodelete Images Fixed Corner Marker Stereo Features Acqusition Workstation Activate Options Country specific labels WH AWS Version: VF10B Insight BD Third party licenses System version: VA10C Image Quality Unrestricted | Published by Siemens Healthineers AG, 2025 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: XX/XX/2024 | QR70000xxxx 7 How to Perform a Superuser Quick Guide I MAMMOMAT B.brilliant Patient Search How to perform a patient search MAMMOMAT B.brilliant 1. Select Patient from the Patient Browser drop-down and select Search or select the search icons from the browser. Patient Browser Patient Transfer Edit View Worklist Filter Sort Privat T Patient Brov Register ... Num 0 Load to Viewing Patient Transf Load Roport Load Last Report Filming Layout ... Film Task Status ... Film Preview ... Expose Film Task Ctrl+P Copy to Film Shoot Management of Repeated/Rejected Images Num Ento Show MPPS Print Preview icons Print List Print. Search Search Selected Prefetch Query Close Browser Alt+F4 2. Enter the desired search criteria, such as Patient Name, Patient ID, or Accession Num- ber. Narrow the search by selecting Mammography under the Modality drop-down. Patient Search Patient Name From 10 Node Patient: D Study Date INSPIRATION3070 Date of Birth Study Time FACS1 PACS2 Sex Any Accession Number Modal ty Advanced Search Computer Ternography Digital Racicgraphy Study Description Magnetic Resonance Study D Nuclear Medicine Positron emi ssi on tomography (PET) Referring Physician PPS Start Time Reporting Physician Body Pat Exam 3. Select the Node from which you want to search, i.e., PACS. Node INSPIRATION3070 PACS1 PACS2 4. Select on Search. The folders will be displayed under the Reporting Search section if the system finds a match. Search Clear Type New Query Name Save Import Import Job Status Image List Discard search results on close 5. Highlight the desired folders you want to import and select Import. eporting Search Search Import Impo Ready 6. The selected folders will be retrieved from the desired location, and available on the local database. Unrestricted | Published by Siemens Healthineers AG, 2025 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: XX/XX/2024 | QR70000xxxx 8 How to Check Your Superuser Quick Guide I MAMMOMAT B.brilliant Detector Temperature How to check your detector temperature MAMMOMAT B.brilliant 1. Select Options from the top toolbar. Options Help Switch to Operating System Login ... Maintenance ... End Session ... Auto Enable First PV Configuration ... Service Security 2. Select Service Local Service. Service Local Service Security Remote Service ... Service Account. 3. On the service software page, select OK. (The spaces for the service key will be empty.) Siemens Healthcare Service Software - Internet Explorer provided by Siemens Healthcare SIEMENS Authentication Service Software TC W//S8T39-VBKAJI Cary MAMMOMAT_B.brilliant VA10C MG 1038 WH AWS VF10B SL43P44 syngo VZ25A SL04P06 VA10C Please enter Service Key OK Upload / Enter new Service Key "The Service Software" you are trying to access is protected by copyrights and may only be used by authorized users within the scope of the authorization. We seserve all our rights in the event of any unauthorized use of the Software. Authorization can be acquired by entering into a royalty-bearing Sokware license agreement with Siemens. If you wish to enter into a licence agreement allowing services to be performed on this system under use of the Software, please contact your local Siemens Service Organisation for further information. In case you have questions, please contact your local Siemens Service Organisation for further information. Unrestricted | Published by Siemens Healthineers AG, 2024 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 09/04/2024 | QR700012696 9 Superuser Quick Guide I MAMMOMAT B.brilliant 4. The menu opens, and select Acquisition System. @ Siemens Healthcare Service Software - Internet Explorer provided by Siemens Healthcare X SIEMENS Home Menu Semice Key Exply Date: 20250309| Service LogBook Event Log Rapports Hop Logout Service Software - Siemens Expert TC W//SBT39-VBKAJ Cary MAMMOMAT_B.brilliant VA100 MG 1038 WH AWS VF10B SL43P44 syngo VZ25A SLO4P06 VA10C Device Guard Disabled Configuration DICOM Tests File & Image Tools Backup & Restore Auto Report Acquisition System Usities SoftwareDistribution 5. Under the Detector heading on the left side of the screen, select Detector Management. Acquisition System General System Service Information Extract Savelogs Autodelete Images Fixed Comer Marker Stereo Features Activate Options Country specific labels Image Quality Factory Settings Exposure Programs QC Exposure Programs IP Set Config IPPG Config Tomo Recon Config Advanced Settings Configuration Report User Configuration Procedures PV Names IP Configuration Exposure Program Configuration Rpgs mAs Per Projection Tomo Frame Usage Needle Configuration Export Configuration Detertor Detector Mmagement Remote Service Interface Web Service Interface AEC Configuration Max Compression Force Unrestricted | Published by Siemens Healthineers AG, 2024 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 09/04/2024 | QR700012696 Page 2 of 4 10 Superuser Quick Guide I MAMMOMAT B.brilliant 4. The menu opens, and select Acquisition System. 6. Detector temperature will be displayed in the menu that appears. Read the current temperature line. @ Siemens Healthcare Service Software - Internet Explorer provided by Siemens Heekhcare GmbH Acquisition System Reports Home Help General Detector Information Extract Savelugs Autodalat Images Fixed Conner Marker TF T paral D C-TZ74M21NH14 extra inbarmaton empty Imight LUI image Quality board_serial number LV2-00419 Factory Seaings Loposure Programs detector type IMAM OC Enpowero Programa image width [pixels] IPAG LO image height [pixels] Tome Hacen Config 35.84 Advanced Settings Configuration Report current temperature [ c] 31 000000 osfactor tem parao ro operatori range puj IP Confiquinton Fapesune Programs Ippas 7. Select Home Exit in the upper right-hand corner of this screen. 5. Under the Detector heading on the left side of the screen, select Detector Management. GmbH x | Reports Home neip Unrestricted | Published by Siemens Healthineers AG, 2024 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Unrestricted | Published by Siemens Healthineers AG, 2024 Job Aid Effective Date: 09/04/2024 | QR700012696 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Page 2 of 4 Job Aid Effective Date: 09/04/2024 | QR700012696 Page 3 of 4 11 How to add and configure Superuser Quick Guide I MAMMOMAT B.brilliant new users How to add and configure new users MAMMOMAT B.brilliant Configuring a new user will require four (4) steps: creating the user, configuring the user’s proce- dure preferences, modifying projection view sequences, and then saving the user’s settings. These steps will have to be repeated for each new user. 1. Creating New User: a. Select Options, Configuration, Security, and Configure from the top dropdown menu. b. Select User Management. c. Right-click on Users, New, then User. synge Name User Management Zi Users 2.!!Internal Users New User core Zi! Internal Users i- DICOM Nodes >i DICOM Nodes Si Groups Help ># Groups 8 Roles >3 Roles -tt, Security Managemen d. User tab: i. Name – Tech’s username syngo Security Configuration Eile Help This is not case-sensitive. (PWHAWSF2 -] |Role Fite ii. Full name – tech's first and syngo 8% User Management Usor Member of Owner of ** Users last name Zil Internal Users <4service> ai DICOM Nodes iii. Description- mammographer 2 Groups > Roles tt, Security Managemer Name iv. Password – Never expires ull name checked Description v. Select Apply. New password e. Member of tab: Confirm password .................... i. Add Security Admin. ii. Select Apply. Account is disabled f. Owner of tab: Password never expires i. Add Role Doctor. User cannot change password ii. Add Role MTA. F Account is jocked out iii. Select Apply. OK Apply Cancel Help g. Close security configuration and end session. 2. Configure User Procedure Preferences: a. Log in as the new user. b. From the top drop-down menu, select Options, Configuration, then Procedure Han- dling. Options Help # WH AWS - Configuration Panel Switch to Operating System Login. File Maintenance ... End Session Auto Enable First PV Procedure WH AWS MoodLight Patient Certificate landing C. Transfer C. Browser Handler Configuration. Service ME Security Add Printer Transfer Audit Trail Filming Study Filming Unrestricted | Published by Siemens Healthineers AG, 2025 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 01/02/2025 |QR700017388 12 Superuser Quick Guide I MAMMOMAT B.brilliant c. Select the RIS procedure with a 1 in front, i.e., 1 screening Bilateral Tomo + 2D PRIME. d. Select Copy. Procedures EXPOS Procedure details List of Procedures Name Copy of 1Screening Bilateral Tomo + 2D PRIME 1- QC-raw PHANTOM 1- QC-raw ARTIFACT DETEC Examination purpose Diagnosis 1- QC-raw DET UNIFORMITY 1IScrooning Bilateral Tomo + 2D F Store procedure as Available for all users TICEM - bilateral TICEM - right TICEM - left Show Procedure Code Mammogram + Mag - bilatera Mammogram + Spot - bilatera Mammogram - right - Standar Mammogram - left - Standard Magnification - bilateral Spot - bilateral O Implant - bilateral Implant + Implant displaced - b Constancy Test QC-raw Calibration QC-processed IQ Biopsy Calibration Biopsy Left - Stereo Biopsy Right - Stereo Biopsy Left Tomo + Stereo Biopsy Right Tomo + Stereo Biopsy Left 2D + Tomo + Ster Biopsy Right 2D + Tomo + Ste Tomo - bilateral Tomo + 2D Standard - bilatere Tomo + 2D PRIME - bilateral OC.raw Toma New Copy Delete Set default OK Cancel Apply e. Delete “Copy of 1”, do not modify the procedure name. i. Store procedure as the current user only. ii. This allows you to have the same RIS procedure with a personalized PV se- quence. Procedure details Name Screening Bilateral Tomo + 2D PRIME Examination purpose Diagnosis Store procedure as current user only Show Procedure Code iii. Select Skip InExam Transfer. Auto Decomp Opcomp r Unprocessed Exposure Program set Qc_set2 Default Display Layout 1:1 Autofilming Autoexpose Skip InExam Transfer Unrestricted | Published by Siemens Healthineers AG, 2025 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 01/02/2025 | QR700017388 Page 2 of 5 13 Superuser Quick Guide I MAMMOMAT B.brilliant 3. Navigate to Modify PVS. a. Select the Modify PV Sequence Tab, then change the view sequence by selecting and dragging the projection views listed under the selected PV sequence in the desired order. Procedure Handling Configuration Procedures EXPOSURE Programs Projection names List of Procedures Procedure details Bilateral Mammogram+Spot Name Bilateral Mammogram - PRIME R Mammogram L Mammogram Examination purpose Diagnosis R Mammogram+Mag L Mammogram+Mag Store procedure as Available for all users R Mammogram+Spot L Mammogram+Spot Show Procedure Code Magnification Spot Implant Bilateral Implant+Implant Displaced Bilt F Auto Decomp F Opcomp Constancy Test Calibration QC-raw QC-processed Default Display Layout 11:1 M Biopsy Calibration BiopsyLeft Autofilming Autoexpose Skip InExam Transfer BiopsyRight BiopsyLeft Tomo IP Set Flavor1 BiopsyRight Tomo BiopsyLeft Tomo Plus BiopsyRight Tomo Plus Display Markers Except mag/spot Bilateral Tomo Bilateral Tomo + 2D Bilateral Tomo + 2D PRIME QC-raw Tomo QC-processed Tomo Projection View set Bilateral Mammogram - PRIMI -CC PRIME L-CC PRIME R-MLO PRIME L-MLO PRIME AB_Bilateral Mammogram AB_Bilateral Tomo KK KK KK KK KK KK KK KK KK KK KK KK KK KK KKK New Copy Delete Set default Modify PVS PVS Dialog PVS Dialog Modify PVs Modify PV sequences Modify PVs Modify PV sequences Projection view sequences Projection view sequences (Default)R-CC. R-CC TOMO, L-CC. L-CC TOMO, R-MLO. R-MLO] R.CC TOMO, R-CC. L-CC TOMO L-CC. R-MLO TOMO, R-MLO.L New [Default)R-CC, R-CC TOMO, L-CC, L-CC TOMO, R-MLO, R-MLO] A R-CC TOMO, R-CC. L-CC TOMO. L-CC. R-MLO TOMO, R-MLO. L New Delete Delete Set default Set default elected PV sequence R-CC TOMO R-CC L-CC TOMO L-CC R-CC TOMO R-MLO TOMO L-MLO TOMO R-MLO TOMO R-MLO L-MLO TOMO L-MLO L-CC TOMO Drag a Py and move it to the right position Drag a PV and move it to the right position Example: Example: Example: Example: 2D and Tomo procedure 2D and Tomo procedure Tomo Only procedure Tomo Only procedure OK Cancel Apply OK Cancel Apply b. Select Apply, then OK. c. Repeat for ALL bilateral procedures. Unrestricted | Published by Siemens Healthineers AG, 2025 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 01/02/2025 | QR700017388 Page 3 of 5 14 Superuser Quick Guide I MAMMOMAT B.brilliant 4. After procedures are configured: a. Select the screening mammogram procedure and select Set Default. b. Select apply. c. Uncheck all clinical factory exams (not from RIS), except QC procedures and calibration. d. Move the QC Exams to the top of the list: i. QC-raw ARTIFACT DETECTION ii. QC-PHANTOMS iii. QC-raw COMPRESSION FORCE TEST e. Arrange the exams in the order under the QC exams by dragging them up or using the up/down arrow keys. f. Select Apply after all changes. 5. To change the starting angle for the MLO view, if different from 45° degrees, go to Projection names: a. Select MLO from the list of preset angle configurations. b. Change the preset angle to the desired angle. c. Select Apply. Projection names List of Preset Angle configurations View type Original Modified ML 90.0 90.0 MLO 45.0 45.0 LM 90.0 90.0 LMO 45.0 45.0 0.0 0.0 FB 180.0 180.0 SIO 30.0 30.0 SPEC 0.0 0.0 XCC 0.0 0.0 XCCL 0.0 XCCM 0.0 0.0 CV 0.0 0.0 AT 45.0 45.0 Reset reset Angle: 45.0 ( L-MLO: +45.0, R-MLO: -45.0 ) Unrestricted | Published by Siemens Healthineers AG, 2025 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 01/02/2025 | QR700017388 Page 4 of 5 15 Superuser Quick Guide I MAMMOMAT B.brilliant Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively Operator Manual) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operators Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively Functionality) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthineers AG 2025 Siemens Healthineers Headquarters Local Contact Information Legal Manufacturer Siemens Healthineers AG Siemens Medical Solutions USA, Inc. Siemensstrasse 1 Siemensstraße 3 91301 Forcheim, Germany 40 Liberty Blvd. Forchheim, Germany 91301 Malvern, PA, USA 19355-9998 Phone: +49 9131 84-4746 Phone: +49 9191 18-0 Telephone: +1-888-826-9702 siemens-healthineers .com/radiography siemens-healthineers.com siemens-healthineers .com/en-us 16
- superuser
- manual send
- ui setup