Siemens Healthineers Academy

MAMMOMAT B.brilliant Hardware Overview - USA

This training introduces you to the new MAMMOMAT B.brilliant mammography system. By showing the most important parts, features and functionalities, it will help you to familiarize yourself with the system.

Target group: All users
Audio: Yes
Recommended to be viewed on the following devices: Laptop, desktop computer (sufficiently large display required)

Continue Continue Continue Continue Continue Continue MAMMOMAT B.brilliant hardware overview online training Master Template HILS2218 | Effective Date: 25 Mar 2022 Eff Date: 06 Sep 2024 | QR700012902 ? MAMMOMAT B.brilliant Hardware overview online training This training introduces you to the new MAMMOMAT B.brilliant mammography system. By showing the most important parts, features and functionalities, it will help you to familiarize yourself with the system. Get to know the X-ray stand 1 4 Learn about available features 3 Memorize all parts of the Acquisition Workstation (AWS) 2 Welcome Welcome to the MAMMOMAT B.brilliant hardware overview online training. This training introduces you to the new MAMMOMAT B.brilliant mammography system. By showing the most important parts, features and functionalities, it will help you to familiarize yourself with the system. Table with 2 columns and 4 rows Not all pages contain audio. Some pages invite you to read for yourself or watch a video. All pages show a ? button in the lower-right corner. Select the ? button to get a quick guide through the navigation elements. Select the button in the upper-left corner to display or hide the menu. ? Navigation hints Before you start, we would like to give you a few tips on how to navigate: Enjoy the course! ? Navigation hints Before you start, we would like to give you a few tips on how to navigate: Not all pages contain audio. Some pages invite you to read for yourself or watch a video. All pages show a question mark button in the lower-right corner. Select the button to get a quick guide through the navigation elements. Select the button in the upper-left corner to display or hide the menu. ? X-ray stand The MAMMOMAT B.brilliant is a Full Field Digital Mammography system with a Flat Detector based on amorphous selenium. The X-ray tube used is equipped with a wolfram anode and two focal spots. Select the markers on the right to learn more about the different parts of the system. Then move on to the following slides to dive deeper into the different functions and parts of MAMMOMAT B.brilliant. 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 7 7 7 8 8 8 Emergency STOP button (both sides) Collision protection area Control panel (both sides) Control panel (both sides) Foot switch (both sides) Compression/decompression control knob (both sides) ComfortGuide display Stationary head rest and face shield Attached to the system, remains on position during rotation. Compression unit Object table Swivel arm With X-ray tube and integrated collimator. X-ray stand The MAMMOMAT B.brilliant is a Full Field Digital Mammography system with a Flat Detector based on amorphous selenium. The X-ray tube used is equipped with a wolfram anode and two focal spots. Select the markers on the right to learn more about the different parts of the system. Then move on to the following slides to dive deeper into the different functions and parts of MAMMOMAT B.brilliant. Markers: Emergency STOP button (both sides) Collision protection area Swivel arm With X-ray tube and integrated collimator. Control panel (both sides) Compression/decompression control knob (both sides) ComfortGuide display Stationary head rest and face shield Attached to the system, remains on position during rotation. Object table Compression unit Foot switch (both sides) ? Control panels This ComfortMove button triggers the automatic system movement that toggles between out of the way and home position. It will also switch the collimator light on or off. Please note: Exposures cannot be performed from the out of the way position. Adjust the height of the swivel arm up and down: 69 cm and 150 cm above the floor relative to the 0° angle position. Press and hold the Raise or Lower swivel arm button until it reaches the desired height. It is also possible to control this via the foot switch. The pedals are marked with an X-ray tube icon. Press this button to rotate the swivel arm isocentrically between +180° clockwise and -180° counterclockwise. Use it as well for fine adjustments of the rotation angle of the object table and swivel arm. A rotation of the swivel arm after a Tomo scan to the next required clutch position is also possible. The Ready button triggers the movement to the predefined position for the next acquisition. Briefly press the button so that the swivel arm moves automatically to the next projection view. The angle is displayed on the stand display. You can find four control panels with the same functions. They are located on the system and on the X-ray stand housing. Hover over the different parts on the right to get more information. Control panels You can find four control panels with the same functions. They are located on the system and on the X-ray stand housing. Hover over the different parts on the right to get more information. layer out of way 1: This ComfortMove button triggers the automatic system movement that toggles between out of the way and home position. It will also switch the collimator light on or off. Please note: Exposures cannot be performed from the out of the way position. layer up down 1: Adjust the height of the swivel arm up and down: 69 cm and 150 cm above the floor relative to the 0° angle position. Press and hold the Raise or Lower swivel arm button until it reaches the desired height. It is also possible to control this via the foot switch. The pedals are marked with an X-ray tube icon. layer swivel arm 1 Press this button to rotate the swivel arm isocentrically between +180° clockwise and -180° counterclockwise. Use it as well for fine adjustments of the rotation angle of the object table and swivel arm. A rotation of the swivel arm after a Tomo scan to the next required clutch position is also possible. layer Ready button 1: The Ready button triggers the movement to the predefined position for the next acquisition. Briefly press the button so that the swivel arm moves automatically to the next projection view. The angle is displayed on the stand display. ? Object lighting Object lighting consists of the collimator light, the working light, and the laser line light. The laser line light indicates the center of the collimation field when the working light is in use. The lighting switches on when the foot switch is compressed. The light in use depends on the tube position relative to the detector. Object lighting Object lighting consists of the collimator light, the working light, and the laser line light. The laser line light indicates the center of the collimation field when the working light is in use. The lighting switches on when the foot switch is compressed. The light in use depends on the tube position relative to the detector. ? Foot switches Use the two mirrored foot switches for convenient patient positioning at the X-ray stand. With the foot switches, you can control the motorized compression/decompression and adjust the height of the swivel arm. It is recommended that the foot switches are placed on each side of the X-ray stand. Please note: The object light switches on automatically when the foot-switch pedal is activated. Raise swivel arm (height adjustment) Lower swivel arm (height adjustment) Raise compression plate (decompression) Lower compression plate (compression) Foot switches Use the two mirrored foot switches for convenient patient positioning at the X-ray stand. With the foot switches, you can control the motorized compression/decompression and adjust the height of the swivel arm. It is recommended that the foot switches are placed on each side of the X-ray stand. Please note: The object light switches on automatically when the foot-switch pedal is activated. 1. Raise swivel arm (height adjustment) 2. Lower swivel arm (height adjustment) 3. Raise compression plate (decompression) 4.Lower compression plate (compression) ? Control knobs Compression/decompression is driven by a motor. You can manually adjust the compression with the control knobs on both sides of the system. Compress by turning the knob downward and decompress by turning upward. It is also possible to control this via the foot switch. SoftSpeed: The compression speed automatically decreases when the compression plate comes into contact with the skin (breast). Control knobs Compression and decompression is driven by a motor. You can manually adjust the compression with the control knobs on both sides of the system. Compress by turning the knob downward and decompress by turning upward. It is also possible to control this via the foot switch. SoftSpeed: The compression speed automatically decreases when the compression plate comes into contact with the skin (breast). ? Mood light The MAMMOMAT B.brilliant is equipped with several variations of mood light that you can set as desired. Press the ON/OFF button on the rear side of the swivel arm to switch the mood light ON. Repeatedly press the ON/OFF button to change the brightness or to switch the mood light OFF. Press the mood light color button to define the color. You can find the buttons on the rear side of the swivel arm, beneath the ComfortGuide display. Mood light The MAMMOMAT B.brilliant is equipped with several variations of mood light that you can set as desired. Press the ON/OFF button on the rear side of the swivel arm to switch the mood light ON. Repeatedly press the ON/OFF button to change the brightness or to switch the mood light OFF. Press the mood light color button to define the color. You can find the buttons on the rear side of the swivel arm, beneath the ComfortGuide display. ? ComfortGuide display Click on the markers on the right to get to know what information the ComfortGuide display shows. When the swivel arm rotates, the stand’s display layout changes from landscape to portrait mode, depending on the position of the swivel arm. The types of displayed messages include guiding, movement, warning, and error messages. Please note: The messaging is designed to not cause alarm to patients. Message area Compressed breast thickness in mm Rotation angles Compression force expressed in Newton Procedure name Registered patient name and date of birth ComfortGuide display Click on the markers on the right to get to know what information the ComfortGuide display shows. When the swivel arm rotates, the stand’s display layout changes from landscape to portrait mode, depending on the position of the swivel arm. The types of displayed messages include guiding, movement, warning, and error messages. Please note: The messaging is designed to not cause alarm to patients. Markers: Registered patient name and date of birth Compression force expressed in Newton Compressed breast thickness in mm Procedure name Message area Rotation angles ? Object table and compression unit The flat-panel detector object table (FD) is located in front of the compression unit. The detector in the object table is 24 x 30 cm. The collimator automatically adjusts the radiation field size to the size of the compression plate. When compression is performed, the scales visualize the current value of Compression and Thickness accordingly. Compression unit Object table Object table and compression unit The flat-panel detector object table (FD) is located in front of the compression unit. The detector in the object table is 24 x 30 cm. The collimator automatically adjusts the radiation field size to the size of the compression plate. When compression is performed, the scales visualize the current value of Compression and Thickness accordingly. Markers: Compression unit Object table ? Stationary head rest and face shield The face shield prevents the patient’s head from moving into the beam. You can remove and insert the shield by pushing/pulling while holding both sides of the face shield. The head rest and face shield are fixed and remain in their position during the rotation of the swivel arm. The patient can place their hand on a specially designed hand rest. This improves comfort and provides a feeling of safety during the examination. Stationary head rest and face shield The face shield prevents the patient’s head from moving into the beam. You can remove and insert the shield by pushing/pulling while holding both sides of the face shield. The head rest and face shield are fixed and remain in their position during the rotation of the swivel arm. The patient can place their hand on a specially designed hand rest. This improves comfort and provides a feeling of safety during the examination. ? Acquisition Workstation (AWS) All examinations are managed from the Acquisition Workstation. Select the markers on the left to take a look at the different components of the AWS. Find out more by clicking these buttons: Radiation shield (option) Keyboard Control box Monitors Workstation with DVD drive Control box Exposure Acquisition Workstation (AWS) All examinations are managed from the acquisition workstation. Select the markers on the left to take a look at the different components of the AWS. Find out more by clicking these buttons: Buttons: Control box Exposure Markers: Control box Workstation with DVD drive Keyboard Monitors Radiation shield (option) Layer Control box Hover over the hotspots on the control box to find out more about the functionality of the buttons. system on 1 System ON system off: System OFF radiation 3: Click the Exposure button to release radiation exposure. The button will light up yellow during the exposure. compression 2: Raise compression plate (decompression) emergency button: Emergency STOP button Layer Exposure: You can release radiation with the exposure button on the control box. You can also use a hand or foot switch. They are plugged into the control box. Keep the Exposure button pressed until the image acquisition is completed. Exposure You can release radiation with the Exposure button on the control box. You can also use a hand or foot switch. They are plugged into the control box. Keep the Exposure button pressed until the image acquisition is completed. Control box Hover over the hotspots on the control box to find out more about the functionality of the buttons. Emergency STOP button Raise compression plate (decompression) Click the Exposure button to release radiation exposure. The button will light up yellow during the exposure. System OFF System ON ? During examination, the tube automatically moves out of the way so that it does not obstruct patient positioning. The system moves the object table and the compression unit to 45° (or another preconfigured angle). If required, the swivel arm movement will follow this initial movement. ComfortMove ComfortMove During examination, the tube automatically moves out of the way so that it does not obstruct patient positioning. The system moves the object table and the compression unit to 45° (or another preconfigured angle). If required, the swivel arm movement will follow this initial movement. ? Emergency STOP button STOP buttons are located on both sides of the X-ray stand. You can also find them on the control box at the AWS. In the event of an emergency release due to power failure or an error message, press the STOP button. This will stop all system movements and X-ray radiation. Turn the STOP button clockwise after the situation is rectified to enable X-ray radiation and unit drive again. Please note: Decompression is not performed automatically when the STOP button is pressed! To release the patient, you must decompress manually. Use the emergency compression release button located at the top of the compression unit. Emergency STOP button STOP buttons are located on both sides of the X-ray stand. You can also find them on the control box at the AWS. In the event of an emergency release due to power failure or an error message, press the STOP button. This will stop all system movements and X-ray radiation. Turn the STOP button clockwise after the situation is rectified to enable X-ray radiation and unit drive again. Please note: Decompression is not performed automatically when the STOP button is pressed! To release the patient, you must decompress manually. Use the emergency compression release button located at the top of the compression unit. ? Course review Congratulations. You have completed the MAMMOMAT B.brilliant hardware overview online training. Select the numbered buttons below to review the material before proceeding to the final assessment. Learn about available features and accessories Memorize all parts of the Acquisition Workstation (AWS) Get to know the X-ray stand 1 1 2 2 2 3 3 3 Course review Features The MAMMOMAT B.brilliant mammography system is designed to provide a seamless and efficient workflow for mammography procedures. It features the ComfortMove design, which automatically positions the tube out of the way during examination for enhanced patient comfort. The MAMMOMAT B.brilliant also includes a foot switch for convenient patient positioning, controlling motorized compression/decompression, and adjusting the height of the swivel arm. Additionally, it offers several variations of mood light that can be set as desired, enhancing the patient experience during the examination. The head rest ensures patient comfort during positioning. The fixed face shield prevents the head of the patient from being in the beam line. Acquisition Workstation (AWS) The Acquisition Workstation (AWS) in the MAMMOMAT B.brilliant system is the control center for all examinations. It includes a control box for managing the system's operations, such as releasing radiation and controlling motorized decompression. The AWS also features a workstation with a DVD drive for data storage and retrieval. Additionally, it houses an emergency STOP button for immediate halt of all system movements and X-ray radiation in emergencies. Overall, the AWS plays a crucial role in facilitating the mammography process, ensuring efficient workflow and high-quality imaging results. X-ray stand The X-ray stand in the MAMMOMAT B.brilliant system houses the X-ray tube and integrated collimator within a swivel arm, allowing for versatile imaging from various angles. It features control panels on both sides for easy operation, including adjusting the swivel arm's height and controlling breast compression. An emergency STOP button is present for immediate halt of all system movements and X-ray radiation in emergencies. The stand also includes a ComfortView display that provides essential information such as patient details and procedure specifics. Additionally, it has a foot switch for convenient patient positioning and a stationary head rest for patient comfort. Disclaimer Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Siemens Healthineers HQ | Siemens Healthineers AG Siemensstr. 3 91301 Forchheim Germany Phone: +49 9191 18-0 siemens-healthineers.com ? Disclaimer Assessment Start ? This assessment will test your retention of the presented content. A passing score of 80% or higher is required. You will have 3 attempts to complete the course and earn your certificate . Assessment questions must be answered completely to receive full credit. Partial credit will not be given for assessment questions that require multiple answers. Assessment Select the best answer. ? To stop all system movements and X-ray radiation in the event of an emergency. To release the compression in the event of an emergency. Question 1 of 5 What is the purpose of the MAMMOMAT B.brilliant's Emergency STOP button? To automatically close the room doors in the event of an emergency. To shut down the system in the event of an emergency. Multiple Choice This is not the correct answer. Please try again. This is not the correct answer. Please try again. This is not the correct answer. Please try again. ? Select two (2) answers. Question 2 of 5 Which of the following functions are activated on the MAMMOMAT B.brilliant's control panels? Initiating the ready function when a compression is applied. Adjusting the height of the swivel arm. Rotating the swivel arm isocentrically between +180° clockwise and -180° counterclockwise. Changing the color of the mood light. Multiple Answer One or more answers are incorrect. Select the best answer. ? The center of the collimation field for correct positioning of the breast. The height of the swivel arm. Question 3 of 5 What does the object lighting laser line light in MAMMOMAT B.brilliant indicate? The radiation field size. The compression force expressed in Newton. Multiple Choice This is not the correct answer. Please try again. This is not the correct answer. Please try again. This is not the correct answer. Please try again. Select the best answer. ? To control the motorized compression/decompression and adjust the height of the swivel arm. To stop all system movements and X-ray radiation in the event of an emergency. Question 4 of 5 What is the purpose of the foot switches in MAMMOMAT B.brilliant? To change the brightness of the mood light. To initiate the ready function when a compression is applied. Multiple Choice This is not the correct answer. Please try again. This is not the correct answer. Please try again. This is not the correct answer. Please try again. Select the best answer. ? The compression speed automatically decreases. The compression plate moves faster. Question 5 of 5 What happens when the compression plate comes in contact with the skin (breast)? The compression speed automatically increases. The compression plate stops moving. Multiple Choice This is not the correct answer. Please try again. This is not the correct answer. Please try again. This is not the correct answer. Please try again. Retry Assessment Results %Results.ScorePercent%% %Results.PassPercent%% Continue YOUR SCORE: PASSING SCORE: Assessment Results You have exceeded your number of assessment attempts. Exit You did not pass the course. Select Retry to continue. Congratulations. You passed the course. Exit To access your Certificate of Completion, select the Certificates tab from the learning activity overview page. You can also access the certificate from your PEPconnect transcript. ? You have completed the MAMMOMAT B.brilliant hardware overview online training. Completion details, certificates tab Navigation Help Select the icon above to open the table of contents. Click Next to continue. Next Welcome Slide The timeline displays the slide progression. Slide the orange bar backwards to rewind the timeline. Click Next to continue. Next Timeline Select the buttons to learn more about a topic. Be sure to review all topics before navigating to the next slide. Click Next to continue. Next Tab Arrow Slide Select the X to close the pop-up. Click Next to continue. Next Layer Slide Some images may have a magnifier icon. Select the image to see an enlarged view. Select it again to return to the normal view. Click Next to continue. Next Zoom Slide Some images have a magnifier icon in the bottom-left corner. Select these image to see an enlarged view of the image. Select the image again to return to the normal view. Videos should default to the optimal resolution. However, to change the video resolution select the gear icon. Click Next to continue. Next Video Slide Some images have a magnifier icon in the bottom-left corner. Select these image to see an enlarged view of the image. Select the image again to return to the normal view. Select Submit to record your response. Click the X in the upper right corner to exit the navigation help. Assessment Slide Question Bank 1 MAMMOMAT B.brilliant Hardware Overview - USA

  • b.brilliant
  • mammography
  • flat detector
  • amorphous selenium
  • wolfram anode
  • comfortmove