This job aid introduces you to the Examination task card where you can control the image acquisition and have the current examination images displayed.
Target group: All users
Recommended to be viewed on the following devices: All (incl. tablet and smartphone)

MAMMOMAT B.brilliant Examination Job Aid Examination task card In the Examination task card, you can control the image acquisition and have the current examination images displayed. 1 Menu bar Examination Open patient 2 Task cards Control area with Operator: 3 subtask cards Viewing Procedure: PV sequence: Filming Auto Filming Auto Expose Acquisition Post processing Close patient 4 Image area Procedure: Images 5 Image tab card 1-+ 1-+ ...... Decomp A Generator control field Status bar Image tab card | Projection views You can find the projection views as buttons in the Images subtask card. The icons on the Images subtask card and mouse-over information provide an examination protocol overview. It is not pos- sible to select multiple images simultaneously in the Examination task card. Images 1 First projection view C 2 Last projection view 1 3 Imo 8 180 3 Second projection view 2 Imo Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 SIEMENS Master Template Effective Date: Apr 2023 | HILS 2224 Job Aid Effective Date: 6 Sep 2024 | QR700012902 Healthineers Job Aid | Examination Effective Date: 6 Sep 2024 | QR70001292 You can check the status of a projection view (modifications, exposure progress) by looking at the corresponding symbols in the protocol control. Icon Definition Icon Definition Projection view according Acquired image to default, exposure mlo scheduled Projection view with addi- Exposure interrupted tional positioning indica- mlo* tion (for example, MLO V rolled medial), exposure scheduled Projection view according Repeat/reject image to default, skipped Auto CC Decompression exposure scheduled cc Projection view according Image rejected O to default, magnification mlo exposure scheduled Projection view with addi- Repeated image after acquisi- O tional positioning indica- tion mlo* tion (for example, magni- fication MLO rolled me- dial), magnification expo- sure scheduled Projection view selected Rejected image after reject or for exposure, waiting for reject and repeat mlo system to be ready for ex- posure Projection view according Image transferred individu- to default, Implant expo- ally during examination mlo sure scheduled Projection view according Projection view selected for to default, Prime Mode exposure, system is ready for mlo exposure scheduled mlo exposure Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 SIEMENS Job Aid Effective Date: 6 Sep 2024 | QR700012902 Healthineers Page 2 of 7 Job Aid | Examination Effective Date: 6 Sep 2024 | QR70001292 Projection view according Projection view acquired, im- to default, Tomo Implant ages transferring Im exposure scheduled Projection view according CC to default, TiCEM* expo- IP Projection view acquired; im- age processing ongoing cc sure scheduled Radiation is released D Projection according to default, Specimen expo- CAUTION: X-ray radiation! spec sure scheduled Projection view according Projection view selected for expo- to default, Spot exposure sure; system is not ready. Note: scheduled mlo Some prerequisites have not CC been fulfilled (e.g., OpComp not reached), exposure not possible Projection view according Problem with the MAMMO- to default, Spot magnifi- MAT system (e.g. no connec- cc* cation* exposure sched- uled (Mag Table and Mag mlo tion), exposure not possible Spot, Mag Spot focus, or Mag Spot plus paddle) Projection view according Projection according to de- to default, Tomo Spot* fault, Inspect View exposure CC exposure scheduled (Spot scheduled plus paddle) InSpect Projection view according Projection view according to to default, Combined 2D, default, Combined Prime, CC and tomo exposure sched- cc CC and tomo exposure sched- uled uled Pre-fire* stereo pair expo- Post-fire* stereo pair expo- sures scheduled + + sures scheduled + CC CC CC CC Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 SIEMENS Job Aid Effective Date: 6 Sep 2024 | QR700012902 Healthineers Page 3 of 7 Job Aid | Examination Effective Date: 6 Sep 2024 | QR70001292 Projection view according Projection view according to to default, Pre-fire* tomo default, Post-fire* tomo bi- CC biopsy exposure sched- opsy exposure scheduled uled (only available for CC (only available for tomo bi- tomo biopsy with horizon- opsy with horizontal needle tal needle guidance) guidance) *optional Image area | Generator control field OPDOSE 60-69 mm 27 kV - + W/AM1.01 62 mm Adv. (1) (2) (3) (4) (5) (6) (7) (8) (9) The currently selected exposure parameters appear in the generator control field. The first set- tings displayed are those configured for the selected exposure procedure, the acquisition mode, and the exposure technique. If you want to use parameters other than the preset parameters, de- fine them in the generator control field before you start the exposure. (1) Display and selection of exposure mode: manual, AEC, OpDose, manual OpDose. (2) Display of compression thickness range (OpDose and manual OpDose only). (3) Display and selection of +/- kV. (4) Display and selection of +/- mAs (only manual). (5) Display and selection of anode/filter combination. (6) Overview of current detail parameter settings in Advanced dialog box. (7) Display of currently set focus (small focus/large focus). (8) Display of current compression thickness; Value is displayed if compression is over 30 N. (9) Button to call up Advanced dialog box to change detail parameters. Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 SIEMENS Job Aid Effective Date: 6 Sep 2024 | QR700012902 Healthineers Page 4 of 7 Job Aid | Examination Effective Date: 6 Sep 2024 | QR70001292 Advanced dialog box When you click the Adv. button on the screen, the Advanced dialog box opens. You can change the detail parameter presets for the currently set exposure technique here. The standby mode of the exposure technique determines which options are available. Advanced Grid Position Auto Decompression OPCOMP AEC Segmentation Dose Level 6 In 2 o On 3 › On 4 o On 5 Jormal c Out @ Off @ Off @ Off Low Medium low @ AUTO Normal Medium high High 1 OK Cancel (1) Overview of current settings of the detail parameters (same as generator control field): (a) Option On or Active. (b) Option Off or Not active. (c) Option not available (dependent on the exposure mode) (a) (b) (c) (2) Grid Position: Within/outside the beam (a) In: Within the beam. * (b) Out: Outside the beam. a) (b) (c) (c) AUTO: With PRIME algorithm if licensed. (3) Automatic Decompression: On: Compression will be released automatically after the exposure. Off: Compression will not be released automatically after the exposure. Compression must be released by the user. (4) OpComp: Optimized compression: On: Compression will stop automatically when optimum compression is reached. Off: Compression will not stop automatically when optimum compression is reached. (5) AEC Segmentation: Measurement range for automatic exposure control: On: For dynamic measurement of pixel values over the entire breast. Off: To limit to small, predetermined measurement area. Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 SIEMENS Job Aid Effective Date: 6 Sep 2024 | QR700012902 Healthineers Page 5 of 7 Job Aid | Examination Effective Date: 6 Sep 2024 | QR70001292 (6) Dose Level: (a) Low: Low dose level. (b) Medium low: Reduced dose level. (c) Normal: Standard dose level. (a) (b) (c) (d) (e) (d) Medium high: Elevated dose level. (e) High: High dose level. Status bar | Exposure parameters After an exposure has been taken the exposure information is displayed. When the completed image appears in the image area on the monitor, the exposure parameters are displayed on the image text and the information bar is hidden. 26 kV 83.6 mAS W/AI1.0 1.0 mGy 0 deg 41 mm 51 N ( 1 ) (2) (3) (1) Radiation parameters (kV, mAs, anode/filter combination, dose value). (2) Angle of rotation of the swivel arm. (3) Compression parameter (thickness, compression force). Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 SIEMENS Job Aid Effective Date: 6 Sep 2024 | QR700012902 Healthineers Page 6 of 7 Job Aid | Examination Effective Date: 6 Sep 2024 | QR70001292 Please note this learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (here- inafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Siemens Healthineers HQ I Siemens Healthineers AG Siemensstr. 3 91301 Forchheim Germany Phone: +49 9191 18-0 siemens-healthineers.com Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 SIEMENS Job Aid Effective Date: 6 Sep 2024 | QR700012902 Healthineers Page 7 of 7

  • b.brilliant
  • mammography