MAMMOMAT B.brilliant - Breast biopsy - Examination preparation and demounting (USA)
This video is a step by step guide about the examination preparation and demounting of the biopsy unit of the MAMMOMAT B.brilliant.
Target group: All users
Audio: Yes
Recommended to be viewed on the following devices: Laptop, desktop computer (sufficiently large display required)
Attach the biopsy table by sliding it over the detector and object table. Keep pushing until you hear a click sound which confirms that the table is mounted correctly. Connect the cable of the biopsy unit to the input on the Mammat Be Brilliant device as soon as the connection is successfully. Established the. Orange light on top of the biopsy. Tower will light up. The biopsy unit will now automatically move into home position. To connect the control box, attach the flexible attachment arm onto the bracket on either side of the biopsy table. Then place the control box onto the arm. Connected with the cable to the back of the biopsy tower, the control box is connected correctly and ready for use. When the display illuminates and shows 000, a flashing light on the control box indicates an error. For example, the object table is not connected properly. Connect the compression paddle by inserting it into the system. Bring it to a higher position to easily mount the compression plate. To install the plate, hold the snug together and roll the plate up into position. There are. Two different types of plates, One is fenestrated for vertical. Approach biopsy. The other one is for horizontal approach biopsy. When the biopsy table is mounted, you can see an A with a strikethrough symbol on the comfort guide display. This indicates that automatic movement is disabled. Meaning for any rotation of the system into lateral position, the swivel arm rotational keys need to be used. A message appears on the display which says please attach and remove needle holder. Attach the needle. Holder for safety checkup. The light turns green. Then remove the needle holder again. In order to acquire your initial images. Install the face shield before you position the patient for CC position sitting upright. In case of a horizontal biopsy, no face shield is needed. This. Enables more access to the area for the radiologist. Or physician performing the biopsy. Now you are done with the examination preparation. For further information on how to move forward and perform biopsy in different approaches, please watch the available videos on. PEP Connect. Upon completion of the chosen procedure, drive the tube head out of the way by clicking the out of the way button, then take out the needle. You can remove all of it in one go. Close. The patient on the acquisition workstation, the system will move to home position and you can release the patient.
54 60 93 44.7 8.6 2/9/2024 1/1/1955 43.2 63 MAMMOMAT B.brilliant Breast biopsy - Examination preparation and demounting MENS Select patient Select procedure Please attach and remove needle holder. OPCOMP MIN TUBE Compression (N) Thickness (mm) TABLE Rotation (º) SIEMENS Examination 4:46:42 PM 1 R -14.2 4.9 2 R -5.9 43.2 Encor Patient Transfer Edit View mages Tools PEP Connect, Stereo Biopsy R-SPEC InSpect Scale 346% o.p. Viewing Filming kV: 23 mAs: 63.0 mAs Focus: large Entrance Dose: 0.0 mGy Glandular Dose: 0.00 mGy Station: XPAWSBB1 3a Rainbowstreet Unicom City District 91052 DEU Open patient PEP Connect Acquisition Stereo Biopsy Biopsy Training Need Procedure: Biopsy Right - Stereo Encor Needle: Encor_10G_vert spec auto CC Manual 23 kV 63.0 mAs - Post processing Close patient 64 mm Advanced Skip EndExam Transfer Rules Open Scheduler Scroll Help Thickness: 64 mm Examination Edit View Image Tools Scroll Options Help End examination in progress .. Edit View Scro 0 mAS Healthineers AT B.brilliant Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Unrestricted | Published by Siemens Healthineers AG | C Siemens Healthineers AG, 2024 Siemens Healthineers HQ | Siemens Healthineers AG Siemensstr. 3 91301 Forchheim Germany Phone: +49 9191 18-0 siemens-healthineers.com
- mammo
- bbrilliant
- b brilliant