
MAMMOMAT B.brilliant Advanced Exam Quick Guide
This quick guide will cover routine tasks on your MAMMOMAT B.brilliant. The following job aids provide steps to navigate the software on your system.
MAMMOMAT B.brilliant Advanced Exam Le SIEMENS Quick Guide MAMMOMAT B.brilliant Welcome to Siemens Healthineers This quick guide will cover routine tasks on your MAMMOMAT B.brilliant. The following job aids provide steps to navigate the software on your system. SIEMENS Healthineers Table of contents Changing a procedure after starting an exam 3 How to view in movie mode 4 How to use InEXAM transfer to manually send images 5 How to reprocess a 2D image 6 How to remove display markers 8 How to select a manual exposure 10 Changing a procedure after Advanced Exam Quick Guide I MAMMOMAT B.brilliant starting an exam Changing a procedure after starting an exam Mammomat B.brilliant 1. Open the exam, the procedure must be changed before taking an exposure. 2. Right-click the PV icon to disable the exposure if the first PV is activated. Images ml Disable exposure 3. Select the dropdown arrow to the right of the Procedure dropdown on the open patient subtask card. Select the correct procedure. Procedure: Bilateral-Screenil QC-processed BiopsyLeft Bilateral-Screening IQ Bilateral - Diagnostic Bil Screening Mammo 4. Ensure the views (PVs) are in the correct workflow order. 5. Double-click the 1st icon (PV) in the icon gallery to make the exposure. Unrestricted | Published by Siemens Healthineers AG, 2024 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 01/02/2025 | QR700017388 3 How to view in Movie Mode Advanced Exam Quick Guide I MAMMOMAT B.brilliant How to view in movie mode Mammomat B.brilliant 1. Select the desired image from the icon gallery. 2. Select the Slices icon. Tomo 2 Reconstr. available TOMO R-CC, Pre v auto Reconstruct ... Delete Reconstruction 8 3. Select the Movie Properties icon, and a dialogue box will open. Tomo 2 Reconstr. available TOMO R-CC, Pre auto Reconstruct ... Delete Reconstruction 4. To play, select the forward or backward button. You can adjust the frame speed to your desired speed. Movie Properties X Movie Properties x From To 43 From 213 F Yoyo F YOYO Show graphics Show Curve Show graphics Show Curve User Defined Ilser Definar Frame rate F/s Frame rate F/S 44 = Forward Unrestricted | Published by Siemens Healthineers AG, 2024 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 01/02/2025 | QR700017390 4 Advanced Exam Quick Guide I MAMMOMAT B.brilliant How to use InEXAM transfer to manually send images How to use InEXAM transfer to manually send images MAMMOMAT B.brilliant INExam transfer can send images to configured destinations using the right-click option to transfer. This can be used during an open exam or by re-entering an exam to resend images. 1. Select the image in the image gallery. mlp mio mla mlo 2. Right-click on the image icon → Transfer Image Attributes ... Repeat ... Reject + Repeat ... Correct. Reprocess. Reconstruct Tome Scan Transfer 3. A white arrow indicates that the image transfers to the configured destinations. Do not close the patient until the transfer is complete (the white arrow will go away). Repeat the steps for any other images you need to transfer. mlo mio 4. When the InExam transfer fails, for example, when PACS is down, a red arrow appears on the projection view thumbnail. mlo CC Unrestricted | Published by Siemens Healthineers AG, 2024 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 01/02/2025 | QR700017390 5 Advanced Exam Quick Guide I MAMMOMAT B.brilliant How to reprocess a 2D image How to reprocess a 2D image MAMMOMAT B.brilliant If the quality of an image is unsatisfactory, it can be reprocessed using different parameters without radiating the patient again. 1. Select the 2D image from the image subtask card you want to Reprocess. Images 2. Right-click on the image →select Reprocess from the dropdown. Images Image Attributes. Repeat Reject + Repeat Correct Deprocess Unrestricted | Published by Siemens Healthineers AG, 2024 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 09/04/2024 | QR7000012697 6 Advanced Exam Quick Guide I MAMMOMAT B.brilliant 3. Reprocessing of the image dialogue box is displayed. Select the New IP Set name and the New image processing parameter from the dropdown. Click OK. Reprocessing of the image Please select the new image processing parameter group from the list for the selected image (projection view. R-CC PRIME) and press OK. New IP Set name: Flavor1 New image processing parameter. F1 M Display Markers OK Cancel 4. Select Yes to confirm in the dialogue box. WH AWS ? Are you sure you want to reprocess the image (projection view: R-CC) with the selected image processing parameter group (FO_Gen1)? Yes No .................. 5. The exposure data is reprocessed with the altered parameters and the new image is displayed. Unrestricted | Published by Siemens Healthineers AG, 2024 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 09/04/2024 | QR7000012697 Page 2 of 3 7 How to Remove Display Markers Advanced Exam Quick Guide I MAMMOMAT B.brilliant How to remove display markers MAMMOMAT B.brilliant The reprocess function can also remove the Display Markers if they overlap breast tissue. 1. Select the image from the image subtask card you want to Reprocess. Images 2. Right-click on the image →select Reprocess from the dropdown. Images mage Attributes. Repeat ... Reject + Repeat ... Comect Reprocess ... Unrestricted | Published by Siemens Healthineers AG, 2024 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 09/04/2024 | QR700012699 8 Advanced Exam Quick Guide I MAMMOMAT B.brilliant 3. Reprocessing of the image dialogue box is displayed. Select the New IP Set name and the New image processing parameter from the dropdown and uncheck Display Mark- ers. Select OK. Note: If the image processing does not need to be changed, select the default settings for your image. Reprocessing of the image ? Please select the new image processing parameter group from the list for the selected image (projection view. R-CC PRIME) and press OK. New IP Set name: Flavor1 New image processing parameter. F1 M Display Markers OK Cancel 4. Select Yes to confirm in the dialogue box. WH AWS ? Are you sure you want to reprocess the image (projection view: R-CC) with the selected image processing parameter group (FO_Gen1)? Yes No ..................... 5. The exposure data is reprocessed with the altered parameters, and the new image is dis- played. Unrestricted | Published by Siemens Healthineers AG, 2024 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 09/04/2024 | QR700012699 Page 2 of 3 9 Advanced Exam Quick Guide I MAMMOMAT B.brilliant How to Select a Manual Exposure How to select a manual exposure MAMMOMAT B.brilliant 1. The manual exposure option is unavailable when a Prime icon is selected in the icon gal- lery. The icon must be modified to an icon with Standard 2D acquisition to have manual exposure. OPDOSE OPDOSE AEC Decomp ..... Advanced 2. If the Prime icon is white, it is enabled. Right-click to disable. 3. Right click and select Modify. Images CC cc ™ CC Modify cc Add Insert Delete mlo mlo 4. From the Acquisition Mode dropdown, select Standard 2D and the view you would like to perform. Do not select Prime. Modified Views Please select the view position ahd modifier(s). Acquisition mode Standard 2D Deactivate Auto Decomp for PV (if selected, ensure that the next PV has the same laterality and view position). Axillary Tail Cleavage Implant Displaced Tangential Rolled Inferior Rolled Lateral Rolled Medial Rolled Superior Prefire Magnification Spot Postfire L-ML L-SPEC R-SPEC R-ML L-MLO L-XCC R-XCC R-MLO L-LM _-XCCL R-XCCL R-LM -LMO L-XCCM R-XCCM R-LMO L-CC R-CC L-FB R-FB L-SIO R-SIO New projection view: R-ML OK Cancel Unrestricted | Published by Siemens Healthineers AG, 2024 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 09/04/2024 | QR700012697 10 Advanced Exam Quick Guide I MAMMOMAT B.brilliant 5. Activate the new icon in the icon gallery by double-clicking. 6. Go to the OPDOSE dropdown Manual is now available for selection. OPDOSE AEC Manual OPDOSE 30-39 mm 26 kV - + W/AI0.7 32 mm Adv 7. Select the Manual exposure technique and adjust kVp and mAs according to the breast thickness on the technique chart. OPDOSE AEC Manual OPDOSE 30-39 mm 26 kV + -+ W/A10.7 32 mm Adv Unrestricted | Published by Siemens Healthineers AG, 2024 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: : 09/04/2024 | QR700012697 Page 2 of 3 11 Advanced Exam Quick Guide I MAMMOMAT B.brilliant Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively Operator Manual) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operators Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively Functionality) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthineers AG 2025 Siemens Healthineers Headquarters Local Contact Information Legal Manufacturer Siemens Healthineers AG Siemens Medical Solutions USA, Inc. Siemensstrasse 1 Siemensstraße 3 91301 Forcheim, Germany 40 Liberty Blvd. Forchheim, Germany 91301 Malvern, PA, USA 19355-9998 Phone: +49 9131 84-4746 Phone: +49 9191 18-0 Telephone: +1-888-826-9702 siemens-healthineers .com/radiography siemens-healthineers.com siemens-healthineers .com/en-us 12
- superuser
- manual send
- ui setup