MAMMOMAT B.brilliant ACR® Phantom Submission Quick Guide
This quick guide will cover the ACR Phantom Submission process on your MAMMOMAT B.brilliant.
MAMMOMAT B.brilliant ACR® Phantom Submission Le SIEMENS MAMMOMAT B.brilliant Quick Guide Welcome to Siemens Healthineers This quick guide will cover the ACR Phantom Submission process on your MAMMOMAT B.brilliant. The following job aids provide steps to navigate acquiring the Quality Control images and exporting the images on your system. SIEMENS Healthineers Table of contents Phantom image acquisition for ACR submission 3 How to archive QC images to a USB 7 How to find the SMPTE pattern 8 How to find exposure time on images 9 Phantom Image Acquisition for ACR Phantom Submission Quick Guide I MAMMOMAT B.brilliant ACR Submission Phantom image acquisition for ACR submission MAMMOMAT B.brilliant 2D Phantom 1. Register the patient manually. 2. Select a Screening procedure from the Procedure dropdown on the Open Patient sub- taskcard. a. LCC or RCC (site preference) 3. Select Opdose for the exposure mode. 4. Position the phantom with the chest wall side of the phantom completely flush with the chest wall side of the image receptor. 5. Compress the phantom to Opcomp. 6. Activate the icon and acquire the image. Steps to Export from the Acquisition Workstation (AWS) 1. This needs to be done from the local database. a. Find the folder on the Local Database. b. Locate and select the 2D Phantom. c. Select on Transfer menu, then select the desired destination. Transfer Edit View Worklist Filter S PI Import Ctrl+1 Archive to DVDRW BICITIVO LU .. Send to. Export to .. Eject from DVDRW Eject from ... Finalize Medium and Eject from DVDRW Local Job Status .. Ctrl+L Network Job Status. Ctrl+N Import from Off-line Export to Off-line Save to a USB Record Off-line Files Unrestricted | Published by Siemens Healthineers AG, 2024 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 08/12/2025 | QR700026818 3 ACR Phantom Submission Quick Guide I MAMMOMAT B.brilliant 3D Phantom 1. Register the patient manually. 2. Select a tomo screening procedure from the Procedure dropdown on the Open Patient subtask card. 3. Change the projection view icon to Tomo Only CC. a. Right mouse click on the image icon. b. Select Modify. c. Change the acquisition mode to Tomo, and select a CC projection view. 4. Select Opdose for the exposure mode. 5. Position the phantom with the chest wall side of the phantom completely flush with the chest wall side of the image receptor. 6. Compress to Opcomp. 7. Activate the tomo icon and acquire the image. 8. After reconstruction is complete, adjust the bounding box and reconstruct the image to display the phantom smaller for submission and the scaling factor closer to 100%. a. Select the First View icon in the TOMO subtask card. b. Activate the bounding box by selecting the blue box. Move the top bounding box’s bar to the top of the screen, and move the bottom bar to the bottom of the screen. ACR PHANTOM, TOMO ACR .5/5/1955 L-CC 7/14/2025 4:25:13 PM 4096 C 2048 1363 T PR L-CC Scale T23% o.p. As: 4.8 .29 Institution: 4921 Park Station: BHDGS TOMO L-CC. P .- Reconstruct Select First View to adjust the bounding box c. Select the Reconstruct button. Reconstruct ... Unrestricted | Published by Siemens Healthineers AG, 2025 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 08/12/2025 | QR700026818 Page 2 of 5 4 ACR Phantom Submission Quick Guide I MAMMOMAT B.brilliant 9. Select the default Reconstruction parameter group name in the dropdown. Reconstruction of scan ? Please select the reconstruction parameter group from the list for the selected scan (projection view: L-CC TOMO) and press OK. IP Set name: Flavor1 Reconstruction parameter group name: Premia0_noSeg Insight 2D IPPG for insight 2D: Premia0 Insight 3D IPPG for insight 3D: Premia0_Imp Premie0_Bio Premia0_Biolmp OK Cancel Premia1 Premia1_Imp Premia1_Bio Premie1_Biolmp 10. After reconstruction is complete, scroll to the best slice to export to the USB. OMO TEST 19.93,21-17:19:22-DST-1.3.12.2 ... 9.03.21-17:19:22-DST-1.3.12.2 .. 3/21/1963 21/2019 INCORRECT 21.091PM :21:01 PM 2178 3343 2209 1257 R-CC TOMO MIRTOMO EMPIRE CORRECT cale 245% o.p. Scale 109% o.p. As: 125.8 mAs kV: 28 ngle: -0.0 mAs: 125.8 mAs ocus: large Angle: -0.0 tomp. Force: 86 N Focus: large lice Height: 35 mm of 43 mm Comp. Force: 86 N lice Thickness: 1 mm Slice Height: 35 mm of 43 mm node/Filter: W/Rh Slice Thickness: 1 mm landular Dose: 1.53 mGy Anode/Filter: W/Rh perator: VH Glandular Dose: 1.53 mGy stitution: Peace Harbor Hospital Operator: VH tation: PHMC_MG01 Institution: Peace Harbor Hospital 00 9th street Florence OR 9743. Station: PHMC_MG01 00 9th street Florence OR 9743. Unrestricted | Published by Siemens Healthineers AG, 2025 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 08/12/2025 | QR700026818 Page 3 of 5 5 ACR Phantom Submission Quick Guide I MAMMOMAT B.brilliant Steps to export a single slice from the Acquistion Workstation(AWS) 1. Scroll to the desired slice. 2. Press the Windows key on the keyboard. Type Snipping Tool in the Search bar. Select Open. Appi Documents Settings More Beit match Snipping Tool Apps Snipping Tool Snipping Tool Settings Use the Print Screen key to launch of Open screen snipping 5 Run as administrator 9 ftun as different user [I] Open file location +1 pin to Start +1 pin to taskbar snipping Kool Remete Session in progress, Shown 3. Capture the best slice. Snipping Tool × SP New Mode " Delay = >< Cancel t Options Select the ship mode using the Mode button or click the New button. 4. Select Save As to save the file to a USB. a. Select the USB. b. Enter File Name. c. Select the appropriate file type in the dropdown under Save as type. ACR PHANTOM, TOM .5/5/1955 3988 1363 L-CC TOMO Premia1 Scale 132% o.p. Save As > This PC >> Pictures vc Search Pictures Organize New folder + Quick access No items match your search. Desktop Downloads Documents Pictures This PC 3D Objects Desktop Documents Downloads Music Pictures E Videos . MED_SYSTEM - MED_DATA (D: - MED_PIXEL (E: - MED_SERVICE - MED_COBR (C Network KV: 26 mAs: 119.0 mAs Angle: 0.2 Focus: large Comp. Force: 80 N Slice Thickness: 1.0 mm Slice Height: 37 mm of 48 mm Anode/Filter: W/AI0.7 Glandular Dose: 1.75 mGy Operator: ESG Institution: Barnes Jewish Hospital File name: Capture.JPG Station: BHDG5 4921 Parkview PL St. Louis St. Save as type: JPEG file (* JPG) Date taken: Portable Network Graphic file (PNG) ( *. PNG) GIF file ( *. GIF) JPEG file (* JPG) Single file HTML (MHT) ( MHT) da Caldara Unrestricted | Published by Siemens Healthineers AG, 2025 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 08/12/2025 | QR700026818 Page 4 of 5 6 How to Archive QC Images to a ACR Phantom Submission Quick Guide I MAMMOMAT B.brilliant USB How to archive QC images to a USB MAMMOMAT B.brilliant 1. Insert a flash drive(USB) into the USB port on the PC hard drive. A message will display at the bottom of the screen. PNP Device Mounted - Drive (G): Total Space(304 MB) 2. In the local database, click on the QC study. Highlight the images on the series folder, you want to archive. Local Database QC TEST 2, ARTIFACT DIQC-raw [[2] MAMMOGRAM, Phantom 3. Click on Transfer in the dropdown menu bar, located at the top of the screen. Click Ex- port to Off-line from the dropdown menu. Transfer Edit View Worklist Filter Sort Private Import Ctrl+1 Archive to DVDRW Archive to PACS1 Archive to ... Send to ... Export to. Eject from DVDRW Eject from ... Finalize Medium and Eject from DVDRW Local Job Status ... Ctrl+L Network Job Status ... Ctrl+N Import from Off-line ... Export to Off-line ... Record Off-line Files 4. Select the logical name G:/ from the dropdown, and type the name of the file. Click OK. Export to Off-line Objects should be exported to Logical Name G:\ Path G: Select format DICOM Quality factor 5. A message will display at the bottom of the screen that the export was successfully com- pleted. Export to off-line request for G: successfully completed for patient name: PhantomIQ 6. Right-click on the USB icon, located at the bottom of the screen, to safely eject the USB. The Safely Eject PNP Device message will display. You can remove the USB from the hard drive. Unrestricted | Published by Siemens Healthineers AG, 2025 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 01/02/2025 | QR700017388 7 How to Locate the ACR Phantom Submission Quick Guide I MAMMOMAT B.brilliant SMPTE Pattern How to find the SMPTE pattern MAMMOMAT B.brilliant 1. From the Patient dropdown, click on Browser. Patient Transfer Examination Edit View Viewing Filming Examination Register .. Num 0 Browser Num . Detector Calibration Biopsy Calibration Automated Quality Control 2. Locate the Service Images on the Local Database. 777777 7 Local Database Service Images 3. Locate and highlight the Technical Images, in the series column. SINGLE T Navibackgrounds Local Database. Service Images Technical Images 4. See the thumbnails in the lower portion of the screen. Double-click the SMPTE pattern im- age icon (icon #1) to load the image onto the Viewing tab or highlight the SMPTE pattern image icon and transfer it to the reading station. Palletil name Service Vnade Unrestricted | Published by Siemens Healthineers AG, 2025 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 01/02/2025 | QR700017390 8 How to Find the Exposure Time ACR Phantom Submission Quick Guide I MAMMOMAT B.brilliant on an Image How to find exposure time on images MAMMOMAT B.brilliant 1. Locate the patient in the local database, and highlight the study. 0Patient Browser X Patient Transfer Edit View Filter Sort Private Applications Options Help × ? ? X Local Database 2D +3D Prime, FirstN: FUlateral Tomo + 2D [8] Radiation Dose Structured Report Schedule testnn [7] INSIGHT 2D R-CC, Diagnosis 2. Re-enter the examination. 0 Patient Browser X Patient Transfer Edit View Filter Sort_Private Applications Options Help ? 10 ? ? ? X Local Database. 2D +3D Prime, FirstNar Bilateral Tomo + 2D [8] Radiation Dose Structured Report Scheduler testnn [7] INSIGHT 2D R-CC, Diagnosis 3. Right-click on the image and select image attributes. Images Image Attributes Reprocess. mlo Image attributes Acquisition number 12 Projection view L-CC MAS 103 kV 27 Anode filter VWAI1.0 Dose (mGy] 17.12 AEC region Fixed Acquisition date/time 9/21/2022 12:02:24 PM Exposure time (msec) 609 Close Unrestricted | Published by Siemens Healthineers AG, 2024 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 02/03/2025 | QR700018478 9 ACR Phantom Submission Quick Guide I MAMMOMAT B.brilliant Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively Operator Manual) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operators Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively Functionality) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthineers AG 2025 Siemens Healthineers Headquarters Local Contact Information Legal Manufacturer Siemens Healthineers AG Siemens Medical Solutions USA, Inc. Siemensstrasse 1 Siemensstraße 3 91301 Forcheim, Germany 40 Liberty Blvd. Forchheim, Germany 91301 Malvern, PA, USA 19355-9998 Phone: +49 9131 84-4746 Phone: +49 9191 18-0 Telephone: +1-888-826-9702 siemens-healthineers .com/radiography siemens-healthineers.com siemens-healthineers .com/en-us 10
- image quality
- mammo
- acr submission