MAGNETOM Flow.Platform | System Overview XA70A (USA)

This online training introduce you to the MAGNETOM Flow.Platform system. You will learn more about all functions and basic operations of all relevant system components. 
Target group: All users.

Continue Continue Continue Continue Continue Continue Continue Continue Continue Continue Continue Continue Continue Continue Continue Welcome Master Template HILS2218 | Effective Date: 25 Mar 2022 ? MAGNETOM Flow.Platform system - Online Training This online training will introduce you to the MAGNETOM Flow.Platform system. You will learn more about all functions and the operations of all relevant components. Discover the examination room Perform the patient-side workflow Prepare the system Discover the control room 1 4 3 2 Welcome MR_Flow_OLT_1.1._welcome.wav Welcome to this online training. This online training will introduce you to the MAGNETOM Flow Platform system. You will learn more about all functions and basic operations of all relevant system components. This training is an essential step in improving your ability to use the MAGNETOM Flow Platform system effectively in your clinical practice. Your participation is greatly appreciated, and we encourage you to fully engage with the material presented. So, let's get started! Hints for navigating this online training Before you start, we would like to give you a few tips on how to navigate: Table with 2 columns and 3 rows Not all pages contain audio. Some pages invite you to read for yourself or watch a video. All pages have a ? button in the lower right corner. Click the ? button to get a quick guide through the navigation elements. Some pages have an X button in the upper right corner. Click the X button to return to the overview page and not miss any information provided. Enjoy the course! ? ? Navigation Hints Enter the examination room ? Flow.Platform overview Examination room Select the markers on the left to explore the examination room and the MAGNETOM Flow system. Control room Enter the examination room MR_Flow_OLT_1.3._Systemoverview.wav Select the markers on the left to explore the examination room and the MAGNETOM Flow system. System overview Chapter 1: MAGNETOM Flow.Platform ? Identify all important hardware components in the examination room. Let´s begin! Introduction System Overview Patient table Overview Select&GO display Overview Chapter 01 MR_Flow_OLT_2.1._Chapter1.wav Welcome to Chapter 1 of the MAGNETOM Flow Platform training. In this section, we will cover four key areas: Introduction, System Overview, Patient Table Overview, and Select&GO Display Overview. By the end of this chapter, you should be able to identify all the important hardware components within the examination room. Let's begin by familiarizing ourselves with the system as a whole. ? Introduction Video VIDEO: QR700005633 ? Flow.Platform system overview MAGNETOM Flow 1.5 T; 60 cm platform Patient table The standard table is fixed The optional table configuration has a vertical drive Both can support up to 250 kg Control units You can use the system control unit to operate the system and the patient table. Select&GO display Jogwheel Technical data Height < 2 m Weight < 3.7 T Min. footprint 24 m² Green technologies System Start-up timer Eco Power Mode (Extended) Eco Gradient Mode DryCool technology Select the markers on the right to learn more about the Flow.Platform system. Please note: Based on your system configuration, your device may show differences in terms of look and feel from the displayed one. Different Gradients for different applications B60: 45 mT/m @ 78 T/m/s G60: 61 mT/m @ 217 T/m/s System overview MR_Flow_OLT_2.3._Systemoverview.wav On this slide, you will find markers on the right. Please select these markers to learn more about the Flow Platform system. It is important to note that, depending on your system configuration, your system may look different from what is displayed in this training. Keep this in mind as you proceed. ? Patient Table overview The patient table is used for positioning the patient and the coils. The table comprises several sockets and connections. Select the callouts on the left to learn more about the table features. Patient table Overview MR_Flow_OLT_2.4._Patienttable.wav The patient table is the important component for patient positioning and coil placement. It includes various sockets and connections that are essential for the operating the MR system. To understand the table features in more detail, select the callouts on the left. Each callout will provide you with specific information about the table's functionalities. Infusion Holder* An infusion stand that integrates with the table to ensure fast patient set up for critical patients. *Optional items Organizer kit The organizer kit consists of two hooks and one box. You can easily slide and fix these in the T-shape slot on either side of the patient table. You can hang up the squeeze bulb and headphones on the hooks and place other items in the box. *Optional items The Accessory box* The Headphone and/or squeeze blub holder* Coil connection The coil connectors are at the head end of the table. Watch the video to understand the operating procedures. Table Stop (1) If you need to stop the table, simply press the Table Stop button. To reset it, pull the button out until it clicks. (2) For a manual table movement pull the handle towards the icon to activate the emergency release. Grip the recess handle and pull the table out of the magnet into the home position. 1 2 Spine coil lever To insert and remove the spine coil, pull the release lever. For detailed step-by-step instructions on how to insert the spine coil, you can find further information on the training platform. (1) Squeeze bulb (2) Vacuum cushion (3) Headphones 1 2 3 Foot end of the patient table The paper roll is placed at the foot end of the table frame. It has an oval shape and can hold paper rolls with different sizes in place. This design also improves comfort for tall patients, and protects the connectors at the base of the table. The paper roll cushion* *Optional items Coil sockets at the head end The coil sockets are located at the head end of the patient table. You can either insert the head coil or the appropriate table cushions for positioning the patient. When cleaning the table use the protective cover for coil sockets. Please note: The coil sockets may differ according to system configuration. On the table the spine coil and additional table cushions are placed. The BioMatrix spine coil can be equipped with two respiratory sensors*. The ComfortRest Mattress* is designed to enable comfortable patient setup for imaging that uses the spine coil and support cushion. *Optional items ? Select&GO overview The Select&GO display provides status information as well as several functions: Register patient Patient position Table position and target table position Comfort & Settings menus Body part information and some guidance Connected coils Toolbar Start scan Troubleshooting etc… For more information on the Select&GO, you can find further training videos. Select&GO Overview MR_Flow_OLT_2.5._Select&GO.wav The Select&GO display is your control center, providing status information and access to numerous functions. These include registering the patient, positioning the patient and the table, accessing the Comfort & Settings menus, viewing body part information and guidance, managing connected coils, and utilizing the toolbar. You can also start scans and troubleshoot from this display. For a more in-depth understanding of the Select&GO, additional videos are available on the training platform. Enter the control room ? Flow.Platform overview Examination room Select the marker on the left to explore the control room and the syngo Acquisition Workplace. Control room Enter the control room MR_Flow_OLT_1.4._Systemoverview.wav Select the marker on the left to explore the control room and the syngo Acquisition Workplace. Acquisition Workplace ? Chapter 2: syngo Acquisition Workplace syngo Acquisition Workplace overview Intercom overview myExam Companion Identify all important hardware components in the control room. Chapter 02 MR_Flow_OLT_3.1._Chapter2.wav Welcome to Chapter 2, focusing on the syngo Acquisition Workplace in the control room. In this chapter, we will get an introduction to the syngo Acquisition Workplace, the Intercom functionalities and myExam Companion. By the end of this section, you should be able to identify all the important hardware components in the control room that are essential for the operation of the M R system. ? syngo Acquisition Workplace overview syngo MR Workplace (optional) Is an optional computer that is only used for the evaluation, documentation and post-processing of previously measured images. Patient Video Monitoring Monitor – User Interface Is used to display scan-related content and to monitor acquired images for viewing and post-processing. Optionally, the workplace can be equipped with two monitors. Mouse Left-click: Select & move objects; and execute commands. Right-click: Open the context menu. Center wheel: Scroll and change window values for patient images. Intercom Important operations can be managed from here. Keyboard It is a modified windows keyboard on which some numeric keys have been replaced with frequently used functions. The workplace in the control room is known as the syngo Acquisition Workplace, and is used to operate the software and to monitor and communicate with patients. Select the markers on the right to learn more about the syngo Acquisition Workplace. Please note: Based on your system configuration, the combination of the devices shown may vary. syngo acquisition workplace MR_Flow_OLT_3.2._syngo.wav The central interface of the control room is the syngo Acquisition Workplace. From here you operate the software, monitor patient procedures, and communicate with your patient. To learn more about the syngo Acquisition Workplace, please select the markers on the right. Please note: based on your system configuration, the combination of the devices shown may vary. ? Intercom overview The Intercom can be mounted on the side of your workplace monitor or positioned on the workplace table. With this device, you can do the following: Turn the system on or off Communicate with the patients Stop table movements Get information about the system status Manage emergency situations Select the callouts on the left to learn more about functions at the intercom features. Intercom MR_Flow_OLT_3.3._intercom.wav The Intercom system, which can be mounted on the side of your monitor or placed on the workplace table, is a vital communication tool. With it, you can power the system on or off, communicate with the patient, halt table movements, receive system status updates, and manage emergency situations. To learn more about the Intercom's functions, select the callouts on the left. Intercom head end (1) Audio connection (music in) (2) Reset Table Stop button 1 2 Table Stop Stops table movement immediately Please note: Reset the table stop on the back of the intercom System ON/OFF button Press and hold the button for 2 seconds to switch the system status ON/OFF. The command will be followed by an acoustic signal To end the Standby mode press the System ON/OFF button for two seconds Speak button Allows you to speak to the patient (as long as the button is pressed) Resets the patient alert Mutes the alarm tone Listen button Allows you to listen to the patient in the examination room Resets the patient alert Mutes the alarm tone Speak Volume Slider You can adjust the speaker volume by sliding the finger up and down the bar The LED indicates the volume level when speaking Listen Volume Slider You can adjust the listening volume by sliding the finger up and down the bar The LED indicates the volume level for listening ? Tailored user assistance, enabling every level of expertise and experience: myExam Autopilot myExam Assist myExam Cockpit myExam Companion | User Interface myExam Companion MR_Flow_OLT_3.4._myExam Companion.wav myExam Companion offers tailored user assistance, catering to every level of user expertise and experience. This includes myExam Autopilot, myExam Assist, and myExam Cockpit. These tools are designed to streamline your workflow and enhance the diagnostic process. For additional information on these software solutions, further content is available in the training platform. VIDEO: QR700005633 MR system operation Chapter 3: System operation ? Plan the examination step by step. Preparation Steps Patient-side workflow Finalizing Steps System Operation MR_Flow_OLT_4.1._systemop.wav Chapter 3 will guide you through the System Operation, including Preparation Steps, Patient-side Workflow, and Finalizing Steps. The objective of this chapter is to enable you to plan the examination step by step, ensuring a smooth and efficient process from start to finish with the Flow Platform. Preparation of the system To start scanning operations, please make sure that the following preparations of the system start-up are executed properly: Safety-related checks Switching on the MR system Checking the MR system components Please note: Do not perform any preliminary examination steps, for example, moving the table and/or connecting coils while starting up the system. Select the numbered steps below to learn more about the execution order. 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 ? Preparation of the System MR_Flow_OLT_4.2._preparation.wav To start scanning operations, it is imperative to execute the system start-up preparations correctly. These include safety-related checks, switching on the M R system, and checking the M R system components. Please note: Do not perform any preliminary examination steps, for example, moving the table and,or connecting coils while starting up the system. Follow the numbered steps below to understand the correct execution order. MR_Flow_OLT_4.2.1._prep1.wav Step1: Safety-related checks. Prior to using the M R system, it is crucial to adhere to the trained safety measures. This includes verifying the functionality and cleanliness of parts and areas such as the examination room and control room. It is essential to comply with the general safety instructions provided in the M R safety training material. In addition, please refer to the detailed checklist in the Safety Information JobAid for the Flow.Platform. MR_Flow_OLT_4.2.2._prep2.wav Step 2: System ON. To activate the system, press and hold the System ON/OFF button for 2 seconds until you are signaled both acoustically and visually. The syngo Acquisition Workplace software will start automatically. If a M R Workplace is present, turn the System On at the intercom first, then switch the Power ON button at the computer. The power supply is separate from the syngo acquisition workplace. MR_Flow_OLT_4.2.3._prep3.wav Step 3: System Check. Look for the System Check icon on the Home Screen. A red icon indicates the need to review the Message History for the M R Scanner and Acquisition and to potentially contact Siemens Healthineers Service. If the icon is green, the system indicates readiness for operation. MR_Flow_OLT_4.2.4._prep4.wav Step 4: Table Stop. Ensure that all Table Stop buttons, located at the intercom and on the patient table, are functioning correctly and can immediately stop the table movement. Remember, the Table Stop button must be reset on the component where it was activated. MR_Flow_OLT_4.2.5._prep5.wav Step 5: Patient Communication. Confirm that pressing the squeeze bulb activates the patient alert. Test the intercom for functionality, including patient communication, LED indicators, and sound. Also, verify that the patient video monitoring system is transmitting images correctly. MR_Flow_OLT_4.2.6._prep6.wav Step 6: Final Check. Once all checks have successfully been completed, you are ready to begin scanning. If the system check on the Home Screen displays a red cross or a warning icon, indicating errors, consult the message box in the bottom right part of the screen for details. Should you encounter issues, such as those related to magnet cooling, contact Siemens Healthineers Service for support. Please refrain from performing any preliminary examination steps, such as moving the table or connecting coils, while the system is starting up. 6 Final check If everything is checked successfully, you can start scanning. If the system check on the Home Screen is marked by a red cross or by a warning icon, indicating errors, check the messages from the message box in the bottom right part of the screen. If there is, for example, an issue relating to magnet cooling, contact Siemens Healthineers Service for support. Please note: Do not perform any preliminary examination steps, for example, moving the table and/or connecting coils while starting up the system. Step 5 – Patient communication 5 Check the intercom functionalities (e.g., patient communication, LED, sound). Check that the patient video monitoring system transmit images properly. Verify that pressing the squeeze bulb triggers the patient alert. Step 4 – Table Stop 4 Check all Table Stop buttons to ensure they can immediately stop the table movement (i.e., on the intercom and at the patient table). Please note: The Table Stop button must always be reset on the component on which it was activated. Step 3 – System check 3 Look for the System Check icon on the Home Screen. If it's red, review the Message History - MR Scanner and Acquisition and contact Siemens Healthineers Service. Otherwise wait until the system is ready for operation as shown by the System Check icon on the Home Screen. Step 2 – System ON 2 To turn ON the system, press and hold the System ON/OFF button for 2 seconds until you receive an acoustic and visual signal. The software automatically starts at the syngo Acquisition Workplace. Please note: If a MR Workplace is present, turn the system on at the intercom first, then switch the Power ON button at the computer. The power supply is separate from the syngo Acquisition Workplace. Step 1 – Safety-related checks 1 Before using the MR system, it’s always important to observe the trained safety measures and to check the functionality and cleanliness of certain parts and areas (e.g., examination room, control room, etc.). Please note: The general safety instructions provided in the safety online training material needs to be taken into account. In addition, please refer to the detailed checklist in the Safety Information JobAid for the Flow.Platform. ? Please watch the video detailing the individual process steps for the patient-side workflow. Preparation of the patient Video with Text MR_Flow_OLT_4.3._video.wav Please watch the video detailing the individual process steps for the patient-side workflow. VIDEO: QR700005633 Finalizing steps Select the tab arrows to learn more about the different options. After the examination is finished and the patient has left, remove the coils carefully and clean the device to be prepared for the next use. If no further examinations are required, the device can be switched off in various ways: Shutting down in the software Switching OFF at the Intercom Standby mode in the software ? Shut Down the System MR_Flow_OLT_4.4._Finalizing steps.wav After completing the examination and once the patient has left, remove the coils carefully and clean the device in preparation for the next use. If no further examinations are scheduled, the device can be switched off using various methods: Shutting down using the software interface, switching off at the intercom, or entering standby mode in the software. Use the tab arrows to learn more about each option. MR_Flow_OLT_4.4.1._tab1.wav Tab 1 Shutting down your MR system using the software interface. First, ensure that all workflows, examinations, and applications are saved and closed at your workplace. Navigate to the Home screen and select the Shutdown icon. A dialog box will appear; here, you should choose "Shut Down System." This action not only turns off the system but also activates the power-saving mode for the MR cooling system. It's important to remember that shutting down the system will also power off the host and the MARS, which means no further measurements or image evaluations can be conducted on the MR system until it is restarted. MR_Flow_OLT_4.4.2._tab2.wav Tab 2 Switching off at the Intercom: For instances where the MR system needs to be turned off completely for an extended period, the intercom provides a solution. To switch off the MR system, press and hold the ON/OFF button for 2 seconds. You will know the process has been initiated by an acoustic and visual signal. This action will also terminate the software at the syngo Acquisition Workplace. If the system is not responding, a forced hard shutdown can be initiated by pressing and holding the ON/OFF button for 13 seconds. MR_Flow_OLT_4.4.3._tab3.wav Tab 3 Standby mode: If your schedule does not include measurements for a considerable time, or you only need to edit or evaluate images, consider using the Standby mode to conserve energy. In Standby mode, the MARS is shut down, while the host and the MR cooling system's power-saving mode are activated. Please note that measurements cannot be performed in this mode. To enter Standby mode, select it from the shutdown icon options. To exit Standby mode, you can either select "Wake up System" from the same menu or press the ON/OFF button on the intercom for 2 seconds. Standby mode in the software If you doesn´t perform measurements for a longer period of time or only edit or evaluate images, you can save energy by enabling the Standby mode. You can select the Standby System mode from the shutdown icon options. Please note: The MARS shuts down. The host and the power saving mode of the MR cooling system switch on. You cannot perform measurements in Standby mode. ? You can end the Standby System mode by selecting Wake up System from the Shutdown icon options or pressing the ON/OFF button on the intercom for 2 seconds. Switching OFF at the Intercom If the MR system should be switched off completely for a lengthy period of time, you can switch the MR system off at the intercom. Press the ON/OFF button for 2 seconds until you receive an acoustic and visual signal. The software automatically ends at the syngo Acquisition Workplace as well. If the system is unresponsive, press and hold the ON/OFF button for 13 seconds to force a hard shutdown. ? Shutting down in the software Save and close all workflows, examinations and applications at the workplace. Select the Shutdown icon on the Home screen >> Shut Down System. Please note: If you switch off the system, the MARS and the host will shut down. Therefore no measurements or image evaluation will be possible on the MR system. This shutdown only activates the power saving mode of the MR cooling system. ? Course Review, Disclaimer and Assessment ? Course review Congratulations. You have completed the MAGNETOM Flow.Platform system Online Training course. Select the objectives listed below to review the material. Prepare the system Discover the control room Discover the examination room 1 1 1 3 3 3 2 2 2 4 4 4 Perform the patient-side workflow Course Review MR_Flow_OLT_5.1._Courserev.wav As we conclude this course, let's take a moment to review the learning objectives we set out to achieve. To reinforce your learning, you may select the objectives listed below to review the material. This is an opportunity to revisit any topics you wish to clarify. Finally, we would like to refer you to one further resource that will improve your understanding and knowledge: The MAGNETOM Flow Platform Overview Job Aid. Patient-side workflow You are supported throughout the examination by an efficient patient-side workflow on Select&GO: Registration, positioning and the start of the examination can be performed right next to the patient. Prepare the system Before operating the MAGNETOM Flow, it is crucial to conduct a thorough safety and functionality check. This includes a general check of safety topics, room conditions, and the verification of individual MR components (e.g. Intercom, Table Stop). The system's readiness is indicated by the System Check icon. Discover the control room The workplace in the control room is known as the syngo Acquisition Workplace, and is used to operate the software and to monitor and communicate with patients. Discover the examination room New DryCool Technology 1.5 T Magnet; 60 cm bore Gradient strength B60: 45 mT/m @ 78 T/m/s G60: 61 mT/m @ 217 T/m/s Select&GO Display Patient registration Push-button isopositioning Start scan Sustainable energy saving technologies System Start-up timer Eco Power Mode (Extended) Eco Gradient Mode DryCool Technology Technical data Height < 2 m Weight < 3.7 T Min. footprint 24 m² Disclaimer Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Siemens Healthineers HQ | Siemens Healthineers AG Siemensstr. 3 91301 Forchheim Germany Phone: +49 9191 18-0 siemens-healthineers.com ? Disclaimer Assessment Start ? This assessment will test your retention of the presented content. A passing score of 80% or higher is required. You will have 3 attempts to complete the course and earn your certificate . Assessment questions must be answered completely to receive full credit. Partial credit will not be given for assessment questions that require multiple answers. Assessment This assessment will test your retention of the presented content. A passing score of 80% or higher is required to complete the course and earn your certificate . Assessment questions must be answered completely to receive full credit. Partial credit will not be given for assessment questions that require multiple answers. You may repeat the assessment as many times as needed. Select the best answer. ? Question 1 of 6 The patient becomes claustrophobic and wants to stop the examination while the table is moving. Which button should you press on the Intercom? Table Stop button to stop the table movement Listen button to hear the patient Speak button to talk to the patient Table Stop button to stop the table movement Multiple Choice Select the best answer. ? Question 2 of 6 How can you perform a hard shutdown of the system when the software is not responding? Via the intercom by pressing the ON/OFF button for 13 seconds Via the Intercom by pressing the ON/OFF button for 13 seconds Via the Home Screen in the upper right area of the software Via the intercom by pressing the Table Stop button for 5 seconds Multiple Choice ? Select the 3 correct answer. Question 3 of 6 Viewing MR images Which workflow functionalities can you control on the Select&GO display? Start the exam Isopositioning Patient registration Multiple Answer Select the best answer. ? Question 4 of 6 Where is the Table Stop button located in the examination room? At the foot of the patient table At the foot of the patient table On the side of the patient table On the system cover Multiple Choice You did not select the correct answer. Incorrect You did not select the correct answer. Select the best answer. ? Question 5 of 6 The patient pressed the squeeze ball. How do you reset the alert? By pressing the Listen or Speak button on the intercom By pressing the Listen or Speak button on the intercom By double-clicking the Table Stop button on the intercom By going into the examination room and pushing the Table Stop button on the left side of the patient table Multiple Choice Select the best answer. ? Question 6 of 6 What should you do if the System Check icon on the Home Screen displays a red cross? Reset the system from the intercom only Press the System ON/OFF button again Move the table or connect coils Review the Message History and possibly contact Siemens Healthineers Service. Multiple Choice Retry Assessment Results %Results.ScorePercent%% %Results.PassPercent%% Continue YOUR SCORE: PASSING SCORE: Assessment Results You have exceeded your number of assessment attempts. Exit You did not pass the course. Select Retry to continue. Congratulations. You passed the course. Exit To access your Certificate of Completion, select the Certificates tab from the learning activity overview page. You can also access the certificate from your PEPconnect transcript. ? You have completed the MAGNETOM Flow. system Online Training. Completion Navigation Help Select the icon above to open the table of contents. Click Next to continue. Next Welcome Slide The timeline displays the slide progression. Slide the orange bar backwards to rewind the timeline. Click Next to continue. Next Timeline Select the buttons to learn more about a topic. Be sure to review all topics before navigating to the next slide. Click Next to continue. Next Tab Arrow Slide Select the X to close the pop-up. Click Next to continue. Next Layer Slide Select Submit to record your response. Click the X in the upper right corner to exit the navigation help. Assessment Slide MAGNETOM Flow.Platform System Overview (USA) Hier finden Sie ein paar nützliche Links und Dokumente: 1.1 Welcome 2.1 Enter the examination room 3 MAGNETOM Flow.Platform system 3.1 MAGNETOM Flow.Platform 3.2 Introduction 3.3 System overview 3.4 Patient table overview 3.5 Select&GO overview 4.1 Enter the control room 5 syngo Acquisition Workplace 5.1 syngo Acquisition Workplace 5.2 Workplace overview 5.3 Intercom overview 5.4 myExam Companion overview 6 MR System operation 6.1 MR System operation 6.2 Preparation of the system 6.3 Preparation of the patient 6.4 Finalizing steps 7.1 Course review 7.3 Assessment

  • flow
  • flow.ace
  • flow.plus
  • ace
  • plus
  • table movement
  • hardware
  • systemoverview
  • XA70A
  • XA70
  • 70
  • platform
  • 1.5T
  • 60 bore