
MAGNETOM Cima.X / Cima.X Fit | System Overview
This job aid invites you to discover the system, its features and components.
Target group: All users.
Recommended to be viewed on the following devices: All (incl. tablet, smartphone)
SIEMENS Healthineers Discover your system: MAGNETOM Cima.X MAGNETOM Cima.X Fit Template Effective Date: 10 Aug 2021 | HILS 2223 Effective Date: 18 Jan 2024 | QR700004485 Unrestricted I Published by Siemens Healthineers AG I © Siemens Healthineers, 2024 MAGNETOM Cima.X SIEMENS Healthineers System overview Get more info on a Open information on Learn more on PEPconnect by topic: the website clicking on the related link 3T magnet Unrivaled speed in MRI SIEMENS Healthineers 55 x 55 x 50 cm3 FoV With Deep Resolve for TSE, EPI Diffusion 2050 mm scan range & HASTE O Push-button exams & state of the Gemini gradients art productivity tools 2001 mT/m at 200 T/m/s With myExam Companion & MAGNETOM Cima.X powered by Gemini Gradients with Multi-GPA Technology & BioMatrix Technology HydroCore Cooling Ultra-high-density coils with unique BioMatrix Sensors High-channel configuration Tim [204x64] Tim [228x128] Intuitive user environment Latest syngo MR X-line 2 Effective Date: 18 Jan 2024 | QR700004485 1 >= 200 mT/m (+-3% for design tolerances) Unrestricted I Published by Siemens Healthineers AG I © Siemens Healthineers, 2024 MAGNETOM Cima.X Fit1 SIEMENS Healthineers System overview Get more info on a Open information on Learn more on PEPconnect by topic: the website clicking on the related link 3T magnet 50 x 50 x 50 cm3 FoV New extended MRI acceleration SIEMENS 205 cm scan range Healthineers tools with Deep Resolve O BioMatrix 3T coils New Gemini gradients MAGNETOM Cimo.X Fit with ultra-high coil element density powered by Cionini Gradients 2002 mT/m 200 T/m/s With Multi-GPA Technology Push-button exams & state of the art productivity tools with myExam Companion, BioMatrix & High-channel imaging Turbo Suite [228x128] channels simultaneously in one single scan User environment and in one single FOV, each latest syngo MR X-line generating an independent partial image 1 MAGNETOM Cima.X Fit is pending 510(k) clearance, and is not yet commercially available in the United States. Its future availability cannot be 3 guaranteed. Effective Date: 18 Jan 2024 | QR700004485 2 >= 200 mT/m (+-3% for design tolerances) Unrestricted I Published by Siemens Healthineers AG I © Siemens Healthineers, 2024 State-of-the-art technology with the upgrade to SIEMENS Healthineers MAGNETOM Cima.X Fit1 Healthineers> O MACHETOM Chua X MAGNETOM Prisma MAGNETOM Cima.X Fit1 60 cm MAGNETOM Prisma magnet 60 cm MAGNETOM Prisma magnet XR gradients 80/200 Gemini gradients – 2002 /200 Tim 4G [204x64] or [204x128] Tim 4G [228x128] Without BioMatrix technology BioMatrix:sensors, tuners, interfaces Dot Cockpit and Dot Engines myExam Companion and myExam Assist syngo MR VE or X-line syngo MR X-line with many new applications Fixed table or dockable table BioMatrix table or BioMatrix dockable table without eDrive 4 1 MAGNETOM Cima.X Fit is pending 510(k) clearance, and is not yet commercially available in the United States. Its future availability cannot be guaranteed. Effective Date: 18 Jan 2024 | QR700004485 2 >= 200 mT/m (+-3% for design tolerances) Unrestricted I Published by Siemens Healthineers AG I © Siemens Healthineers, 2024 Gemini and Multi-GPA Technology SIEMENS Healthineers Get more info on a Open information on topic: the website 2001 / 200 Multi-GPA Technology HydroCore Cooling • Gemini stands for twin: Both the Cima.X and Cima.X Fit feature a Twin Gradient design which is also reflected in the Multi-GPA of the system. This provides the basis for unprecedented gradient performance. • Multi-GPA Technology covers the two GPAs that drive the gradient. • HydroCore Cooling enables direct thermal contact with the gradient coolant and maximizes thermal energy transfer and dissipation. MAGNETOM Cima.X Fit is pending 510(k) clearance, and is not yet commercially available in the United States. Its future availability cannot be 5 guaranteed. Effective Date: 18 Jan 2024 | QR700004485 Effective Date: 18 Jan 2024 | QR700004485 1 ≥ 200 mT/m (±3% for design tolerances) Unrestricted I Published by Siemens Healthineers AG I © Siemens Healthineers, 2024 MAGNETOM Cima.X provides new power in diffusion imaging SIEMENS Healthineers Signal noise ratio (SNR) Exponentially higher SNR MAGNETOM Previous Time of echo Cima.X high-end gradients 6 MAGNETOM Cima.X Fit is pending 510(k) clearance, and is not yet commercially available in the United States. Its future availability cannot be guaranteed. Effective Date: 18 Jan 2024 | QR700004485 Effective Date: 18 Jan 2024 | QR700004485 b=10000. Identical scan parameters. Data on file. Based on internal measurements. Unrestricted I Published by Siemens Healthineers AG I © Siemens Healthineers, 2024 Gemini gradients enable access to high SIEMENS Healthineers b-values in significantly shorter scan times b0 b2000 b5000 b10000 MAGNETOM Cima.X powered by TA 6:32 min HydroCore Cooling TR = 4800 ms, TE = 81 ms MAGNETOM Prisma TA 28:25 min TR = 21500 ms, TE = 108 ms 7 MAGNETOM Cima.X Fit is pending 510(k) clearance, and is not yet commercially available in the United States. Its future availability cannot be guaranteed. Effective Date: 18 Jan 2024 | QR700004485 Effective Date: 18 Jan 2024 | QR700004485 Study-ID: 2aaaa2652. Imaging parameters: p3, Deep Resolve, 0.6x0.6x4.0mm³, averages: b0 = 1, b2000 = 3, b5000 = 7, b10000 = 9 Unrestricted I Published by Siemens Healthineers AG I © Siemens Healthineers, 2024 Patient workflow and user assistance SIEMENS Healthineers Get more info on Open PEPconnect a topic: training material SIEMENS Healthineers . Healthingers O MACHETOM Cima.x - Easy patient preparation Comprehensive coil portfolio Automated scan workflow featuring BioMatrix technology including BioMatrix sensors assisted by myExam Companion 8 Effective Date: 18 Jan 2024 | QR700004485 MAGNETOM Cima.X Fit is pending 510(k) clearance, and is not yet commercially available in the United States. Its future availability cannot be guaranteed. Unrestricted I Published by Siemens Healthineers AG I © Siemens Healthineers, 2024 Coil portfolio (1/5) SIEMENS Healthineers Get more info on Open PEPconnect a topic: training material Trade-in available for BioMatrix Body 185 V V Interchangeable with MAGNETOM Cima.X1 BioMatrix Head/Neck 20 Body 183,4 MAGNETOM Vida tiltable and with Coilshim MAGNETOM Vida Fit Trade-in available for Interchangeable with UltraFlex 18 Large/ Small5 V MAGNETOM Lumina ............ S ................. V Interchangeable with MAGNETOM Prisma BioMatrix Spine 32 Flex 4 Large/Small4 and Biomatrix Spine V Interchangeable with 722 with Respiratory MAGNETOM Skyra Sensors 9 1 MAGNETOM Cima.X Fit is pending 510(k) clearance. It is not commercially available in the U.S.A and their future availability cannot be guaranteed. Effective Date: 18 Jan 2024 | QR700004485 2 BioMatrix Spine 72 is only interchangeable with MAGNETOM Vida and available for MAGNETOM Cima.X Fit. | 3 Body 18 is only interchangeable with MAGNETOM Vida and MAGNETOM Vida Fit.| 4 Original Body 18, Flex 4 Large and Flex 4 Small coils from MAGNETOM Prisma remain with MAGNETOM Cima.X Fit. Trade-in for upgrades available as Unrestricted I Published by Siemens Healthineers AG I © Siemens Healthineers, 2024 purchased items. | 5 Only available for MAGNETOM Cima.Fit. Coil portfolio (2/5) SIEMENS Healthineers Get more info on Open PEPconnect a topic: training material Tx/Rx CP BM Head/Neck 64 V Trade-in offer available2 Head 32 Head Coil with CoilShim Interchangeable with MAGNETOM Cima.X1 V MAGNETOM Vida MAGNETOM Vida Fit MAGNETOM Lumina V Interchangeable with V V MAGNETOM Prisma BioMatrix Body 18 Body 18 Long Body 30 with Beat Sensor V Interchangeable with MAGNETOM Skyra 10 1 MAGNETOM Cima.X Fit is pending 510(k) clearance. It is not commercially available in the U.S.A and their future availability cannot be guaranteed. Effective Date: 18 Jan 2024 | QR700004485 2 Only available for MAGNETOM Cima.X Fit. Unrestricted I Published by Siemens Healthineers AG I © Siemens Healthineers, 2024 Coil portfolio (3/5) SIEMENS Healthineers Get more info on Open PEPconnect a topic: training material V V Trade-in offer available2 Tx/Rx Knee 18 Foot/Ankle 16 UltraFlex 18 Small Interchangeable with MAGENTOM Cima.X1 MAGNETOM Vida MAGNETOM Vida Fit MAGNETOM Lumina - V Interchangeable with V V MAGNETOM Prisma Shoulder Shape 16 Hand/Wrist 16 UltraFlex 18 Large V Interchangeable with MAGNETOM Skyra 1 MAGNETOM Cima.X Fit is pending 510(k) clearance. It is not commercially available in the U.S.A and their future availability cannot be guaranteed. 11 2 Only available for MAGNETOM Cima.X Fit. Effective Date: 18 Jan 2024 | QR700004485 Unrestricted I Published by Siemens Healthineers AG I © Siemens Healthineers, 2024 Coil portfolio (4/5) SIEMENS Healthineers Get more info on Open PEPconnect a topic: training material SIEMENS Peripheral Endorectal Loop Coils Angio 36 Coil Kit Interchangeable with MAGNETOM Vida V MAGNETOM Vida Fit MAGNETOM Lumina MAGNETOM Cima.X1 V Interchangeable with MAGNETOM Prisma Special Purpose 4 Pediatric 162 V Interchangeable with MAGNETOM Skyra 1 MAGNETOM Cima.X Fit is pending 510(k) clearance. It is not commercially available in the U.S.A and their future availability cannot be guaranteed. 12 2 MR scanning has not been established as safe for imaging fetuses and infants under two years of age. The responsible physician must evaluate the benefit of Effective Date: 18 Jan 2024 | QR700004485 the MRI examination in comparison to other imaging procedures. Unrestricted I Published by Siemens Healthineers AG I © Siemens Healthineers, 2024 Coil portfolio (5/5) SIEMENS Healthineers Get more info on Open PEPconnect a topic: training material SIEMENS Breast 18 2/10/16 Sentinelle Breast Diagnostic Breast 18 coil Breast Biopsy Software supports 2/10/16/ Sentinelle Breast and 2/4/8 Sentinelle Breast Interchangeable with MAGNETOM Vida V MAGNETOM Vida Fit MAGNETOM Lumina MAGNETOM Cima.X1 V Interchangeable with MAGNETOM Prisma V Interchangeable with MAGNETOM Skyra Breast BI 7 V V 13 Effective Date: 18 Jan 2024 | QR700004485 1 MAGNETOM Cima.X Fit is pending 510(k) clearance. It is not commercially available in the U.S.A and their future availability cannot be guaranteed. Unrestricted I Published by Siemens Healthineers AG I © Siemens Healthineers, 2024 Features SIEMENS Healthineers Physiologging 7 sec 1| Auto @ None @ 3.9x3.9x5.0 mm3 1.00 Get more info on Open PEPconnect a topic: Routine Contrast Resolution Geometry System Physio BOLD Inline Sequence training material Signal • Physiologging of time- 1st Signal/Mode Resp./Trigger stamped physiology signals for fMRI data correction Average Cycle 3000 + 0 ms • Access time-synced sensor data for fMRI scans as part Acquisition Window 1500 of the DICOM study ms 3.5 6.3 17.5[s] • Sample code available for Threshold 20 % Concatenations extraction • Resp. Phase Expiration Available for EPI BOLD & PACE Trigger Delay ms • Supports all internal O TR 219.0 sensors – external sensors ms from third-party vendors Log Signals are not supported 14 Effective Date: 18 Jan 2024 | QR700004485 Effective Date: 18 Jan 2024 | QR700004485 Unrestricted I Published by Siemens Healthineers AG I © Siemens Healthineers, 2024 Features SIEMENS Healthineers Open Recon Get more info on Open PEPconnect a topic: training material USER >> head >> Brain Assist > program >> t1_qtse_dark-fluid_sag_p2 ? X General @ 4:38 min 4 Auto @ 2 @ 0.7x0.7×4.0 mm3 @ 1.00 Protocol Parameters Inline use Routine Contrast Resolution Geometry System Physio Inline Sequence Voice Commands Run custom prototype image Execution Subtraction MIP Composing Open Recon reconstruction on the scanner Image Management Algorithm myRecon 1 Auto Load 3 rd party or custom Copy References algorithm Preview Select 3rd party or custom Preset denoise Parameter 1 Setting A reconstruction algorithm to be Free Text denoise denoise-enhanced-level1 ... Parameter 2 Setting B mg run denoise-enhanced-level2 denoise-enhanced-level3 Option 1 User-friendly interface super-resolution Option 2 Adapt parameters provided by smooth-super-resolution edge-super-resolution the algorithm as on any other super-resolution-gre-mpr tab card super-resolution-dwi MAGNETOM Cima.X Fit and Open Recon are pending 510(k) clearance, and are not yet commercially available in the United States. Their future availability cannot be guaranteed. 15 Open Recon is to add clinical reconstructions to the system, if signed and released for clinical use by SHS. Any other recon used, e.g. by researchers, is Effective Date: 18 Jan 2024 | QR700004485 Effective Date: 18 Jan 2024 | QR700004485 automatically labeled not for diagnostic use, which may require observation of national regulations. Unrestricted I Published by Siemens Healthineers AG I © Siemens Healthineers, 2024 Acceleration techniques SIEMENS Healthineers Get more info on Open PEPconnect a topic: training material Deep Resolve Simultaneous Multi-Slice Compressed Sensing Parallel Imaging 16 MAGNETOM Cima.X Fit is pending 510(k) clearance, and is not yet commercially available in the United States. Their future availability cannot be Effective Date: 18 Jan 2024 | QR700004485 Effective Date: 18 Jan 2024 | QR700004485 guaranteed. Unrestricted I Published by Siemens Healthineers AG I © Siemens Healthineers, 2024 Deep Resolve SIEMENS Healthineers Image examples – Brain Conventional Deep Resolve 74% AI faster 2x Deep neural network resolution T2 TSE T2 TSE 0.4 x 0.4 x 4.0 mm3 PAT 4, Deep Resolve TA 2:07 min 0.2 x 0.2 x 4.0 mm3 TA 0:33 min 17 MAGNETOM Cima.X Fit is pending 510(k) clearance, and is not yet commercially available in the United States. Its future availability cannot be guaranteed. Effective Date: 18 Jan 2024 | QR700004485 Effective Date: 18 Jan 2024 | QR700004485 Study-ID: 2aaaa2742, MAGNETOM Cima.X, 28 slices Unrestricted I Published by Siemens Healthineers AG I © Siemens Healthineers, 2024 Deep Resolve for TSE and EPI diffusion SIEMENS Healthineers Image examples - Prostate T2 TSE tra T2 TSE cor T2 TSE sag DWI b1400 PAT 4, Deep Resolve PAT 4, Deep Resolve PAT 4, Deep Resolve PAT 3, Deep Resolve 0.3 x 0.3 x 3.0 mm³ 0.3 x 0.3 x 3.0 mm³ 0.3 x 0.3 x 3.0 mm³ 0.8 x 0.8 x 3.0 mm³ TA 0:53 min TA 0:49 min TA 0:49 min TA 1:21 min Total scan time: 03:52 min MAGNETOM Cima.X Fit is pending 510(k) clearance, and is not yet commercially available in the United States. Its future availability cannot be 18 guaranteed. Effective Date: 18 Jan 2024 | QR700004485 Effective Date: 18 Jan 2024 | QR700004485 Study-ID = 2aaaa2648 Unrestricted I Published by Siemens Healthineers AG I © Siemens Healthineers, 2024 SIEMENS Healthineers Please note this learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. © Siemens Healthineers AG 2024 Siemens Healthineers Headquarters Siemens Healthineers AG Siemensstr. 3 91301 Forchheim, Germany Telephone: +49 9191 18-0 siemens-healthineers.com 19 Effective Date: 18 Jan 2024 | QR700004485 Unrestricted I Published by Siemens Healthineers AG I © Siemens Healthineers, 2024
- cima.x
- cima
- cima x fit
- x fit
- features
- cima system
- cima overview