2nd comprehensive breast examination: DBT and TiCEM were able to detect the tumor, that was not visible on the 2D mammograms, and showed a good correlation with MR:  
FFDM, IN2D, DBT, TiCEM, US, MR.

This case was a 63 year old lady with no symptoms. Here you can see the conventional mammograms. There are places scarred due to previous surgery. We used invasive ductal cancer several years ago. And there are no clear signs of malignancy in this. In these mammograms. However, one tomosynthesis would detected an irregular spiculated mass in the outer quadrants of the right breast. Here and here. If we focus on the right breast, you can see the conventional mammogram and. On tomosynthesis, the stipulated mass, and if we apply, if we use that spot compression then we can see clearly the stipulated irregular mass. If we move to the Malibu again, we can see clearly. The regular speculated mass. By using atomal spot. This is the Dyson study showing an enhancing mass. As you can see, the normal fibroglandular tissue is subtracted. And finally, the correlation with ultrasound. And Emory? The result was a 12 millimeter invasive lobular cancer.

1/1/2022 43 5.0 10/29/2021 23 9.0 21 69 Introduction 2 Digital Breast Tomosynthesis and Contrast Enhanced Mammography Prof. Dr. Luis Pina Breast Imaging Department (Radiología mamaria) Clínica Universidad de Navarra, Pamplona / Spain SIEMENS . 02_Impressing_2, PID3693 * 1/1/2022 F PID3693 Series Navigator INSIGHT_2D Add Study PID3693 10/1/2021 (Study date) Current Prior 01 US, 10/18/2021 12:57:21 P .. MR, 10/29/2021 9:06:49 A ... MG, 10/1/2021 n.a ., 6 mon ... Mamograffa unilateral con contraste Viewing Favorite Layouts US MR DYN MR.Dyna ... MR.Empty ReportFlow BASIC Printing Tools Findings MR 2:40 PM MRI Clinical information 63-year-old female Asymptomatic Previous surgery of left breast DYN Healthineers C.US | C .... LCC LMLO Prior 01 Prior 01 Slice 10 / 34 Slice 18 / 33 Slice thickness: 1.00 mm Slice thickness: 1.00 mm |Slice thickness: 1.00 mm Slice 18/ 32 Slice 10/33 Slice 11 / 34 Slice 9 / 33 Slice 6 / 26 RCC RMLO LowEnergy Recombined 1 CLINICA UNIVERSITARIA DE NAVARRA 10/18/2021, 12:57:21 PM (Study date) 1 CLINICA UNIVERSITARIA DE ADM Mama FR BASI Subtraction 9:23:41 AM 11 IMA 40 p2 1.5 mm SP H0.4 Zoom 1.70 C.CC SL 1.5 mm 1/1/2022, F Pathology Invasive lobular carcinoma (ILC) 12 mm MR.Dyna Conclusion DBT and TiCEM were able to detect the tumor, that was not visible on the 2D mammograms, and showed a good correlation with MRI.+ Siemens Healthcare GmbH, 2022 Sometimes IN2D images (= synthetic mammograms) are shown while verbally referring to the conventional mammograms. The products/features (mentioned herein) are not commercially available in all countries. Their future availability cannot be guaranteed. Results from case studies are not predictive of results in other cases. Results in other cases may vary. The statements by Siemens' customers described herein are based on results that were achieved in the customer's unique setting. Since there is no "typical" setting and many variables exist (e.g ., hospital size, samples mix, case mix, level of IT adoption) there can be no guarantee that other customers will achieve the same results. Dr. Luis Pina is employed by an institution that receives financial support from Siemens Healthineers for collaborations. SIEMENS Hea

  • ffdm
  • in2d
  • dbt
  • tumor