Siemens Healthineers Academy

Invasive Ductal Carcinoma - TiCEM Multifocal (USA)

TiCEM was better than DBT to detect this multifocal IDC:  
IN2D, DBT, TiCEM, US.

76 year old lady with a previous history of invasive ductal cancer in the left breast. This patient had severe obesity and here you can see the insight to the views. Showing the scar in the left breast and no significant lesions. Then we go to the. It's almost synthesis showing the scar in the left breast. And a tightness species mass spiculated mass in the right breast. If we focus in this white breast. Kind of. See. These subtle speculated mass that could only be clearly detected on the envelope. We performed a Dyson study because. An MRI study was impossible for this patient due to overweight and claustrophobia. And as you can see in this Tyson study we detected. More additional lesions. At least. Three additional lesions in this breast. So multi Focality was suspected. Second look, ultrasound was performed detecting detecting some additional lesions and a biopsy was performed. So the final result was multifocal invasive ductal cancer. Luminal a subtype. All of the lesions were smaller than 5 millimeters. So the conclusion of this case is that Tyson was better than DVD's to detect multifocal cancer.

5:27 5:29 Preoperative 2 Digital Breast Tomosynthesis and Contrast Enhanced Mammography Prof. Dr. Luis Pina Breast Imaging Department (Radiología mamaria) Clínica Universidad de Navarra, Pamplona / Spain SIEMENS . 11_PreOp_2, PID3646 * 1/1/2022 F PID3646 LCC Series Navigator RCC INSIGHT_2D Add Study PID3646 11/1/2021 (Study date) Current Prior 01 MG, 1/1/2022 n.a ., 3 mont ... Mamograffa unilateral con contraste RMLOLE RCCLE INSIGHT_CEM_RML Viewing Favorite Layouts US MR DYN MR.Dyna ... IN 2D MR.Empty ReportFlow BASI Printing Tools Findings MR 5:27 PM Clinical information 76-year-old female Previous invasive ductal carcinoma (IDC) left breast Asymptomatic C.US | C .... Healthineers Slice 28 / 65 Slice thickness: 1.00 mm RMLO Prior 01 Prior 01 Slice 14 / 60 Slice 28 /65 Slice 25 / 70 Slice 34 / 77 Slice 25 /70 Slice 28 / 65 Slice 25 / 70 LCCLE Slice 28 / 65 Slice 25/ 70 Slice 29/ 70 Slice 40 / 60 R MG T LowEnergy Recombined Pathology Multifocal invasive ductal carcinoma (IDC) Luminal A, 5 mm Conclusion TiCEM was better than DBT to detect this multifocal IDC. Siemens Healthcare GmbH, 2022 Sometimes IN2D images (= synthetic mammograms) are shown while verbally referring to the conventional mammograms. The products/features (mentioned herein) are not commercially available in all countries. Their future availability cannot be guaranteed. Results from case studies are not predictive of results in other cases. Results in other cases may vary. The statements by Siemens' customers described herein are based on results that were achieved in the customer's unique setting. Since there is no "typical" setting and many variables exist (e.g ., hospital size, samples mix, case mix, level of IT adoption) there can be no guarantee that other customers will achieve the same results. Dr. Luis Pina is employed by an institution that receives financial support from Siemens Healthineers for collaborations. SIEMENS

  • in2d
  • dbt
  • multifocal
  • idc