How to Use Preview Series in Cardiac Imaging VB20 Simulation - USA
You will learn about the two ways how to perform a Preview Series reconstruction for retrospective ECG-gated spiral and prospective ECG-triggered sequence acquisitions in this interactive simulation.
In addition, you will learn about how to clear a Preview Series reconstruction in order to start another one for a different cardiac phase.
Product relevance: SOMATOM go.All, SOMATOM go.Top, SOMATOM X.cite, SOMATOM X.ceed, SOMATOM Pro.Pulse, NAEOTOM Alpha, NAEOTOM Alpha.Peak, NAEOTOM Alpha.Pro, NAEOTOM Alpha.Prime.
Target group: Basic user, all users.
Audio: Yes.
Recommended to be viewed on the following devices: Tablet, laptop, desktop computer (sufficiently large display required).
Continue Continue Continue Continue Continue Welcome and Introduction ? Simulation 1: Perform a Preview Series reconstruction with the default Preview Series recon job (8 min) Simulation 2: Change any recon job to a Preview Series recon job and perform a reconstruction (7 min) How to Use Preview Series in Cardiac Imaging (VB20) – Simulation Preview Series is a reconstruction of a single image at multiple different ECG phases within one recon job. You may already know it from a Somaris 7 system, but it is new to Somaris 10 systems. You can perform a Preview Series reconstruction for retrospective ECG-gated spiral and prospective ECG-triggered sequence acquisitions. Use Preview Series to manually determine the cardiac phase with the least motion present in the images by visual inspection. There are two ways to perform a Preview Series reconstruction. At the end of this training, you should be able to perform these two ways. In addition, you should know how to clear a Preview Series reconstruction in order to start another one for a different cardiac phase. Select the arrows to start each interactive simulation. If you need help for navigating through the simulation, select this button. Welcome and Introduction [Storyboard_CT_VB20_Preview_Series_Sim_01_01.mp3] Preview Series is a reconstruction of a single image at multiple different ECG phases within one recon job. You may already know it from a Somaris 7 system, but it is new to Somaris 10 systems. You can perform a Preview Series reconstruction for retrospective ECG-gated spiral and prospective ECG-triggered sequence acquisitions. Use Preview Series to manually determine the cardiac phase with the least motion present in the images by visual inspection. There are two ways to perform a Preview Series reconstruction. At the end of this training, you should be able to perform these two ways of a Preview Series reconstruction. In addition, you should know how to clear a Preview Series reconstruction in order to start another one for a different cardiac phase. Select the arrows to start each interactive simulation. If you need help for navigating through the simulation, select this button. Disclaimer Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2025 Siemens Healthineers HQ | Siemens Healthineers AG Siemensstr. 3 91301 Forchheim Germany Phone: +49 9191 18-0 siemens-healthineers.com ? Disclaimer Perform Preview Series Recon With Default Preview Series Recon Job Interactive simulation: How to perform a Preview Series reconstruction with the default Preview Series recon job. Prerequisites: You have selected a cardiac scan protocol. Since you can apply Preview Series only to sequence and spiral scan modes, make sure you have selected a corresponding scan mode. Please note: The Preview Series reconstruction is available as default Preview Series recon job, only if you have answered the patient’s Heart Rate Variability decision tree question with Arrhythmic. Select the myExam Compass workflow task to continue. Prerequisites [Storyboard_CT_VB20_Preview_Series_Sim_02_01_inserted.mp3] This interactive simulation will show you how to perform a Preview Series reconstruction with the default Preview Series recon job. Consider the following prerequisites. You’ve selected a cardiac scan protocol. Since you can apply Preview Series only to sequence and spiral scan modes , make sure you’ve selected a corresponding scan mode. Please note: The Preview Series reconstruction is available as default Preview Series recon job, only if you’ve answered the patient’s Heart Rate Variability decision tree question with Arrhythmic. We’ll walk you through this now. Select myExam Compass from the workflow tasks to open the clinical decision tree questions. Please select the myExam Compass workflow task to continue. Select the pen icon to continue. Answer Heart Rate Variability Decision Tree Question [Storyboard_CT_VB20_Preview_Series_Sim_02_02_inserted.mp3] In the Patient Characteristics section of myExam Compass, you’ll find the Heart Rate Variability decision tree question. Select its pen icon to edit. Please select the pen icon to continue. Select Arrhythmic to continue. Answer Heart Rate Variability Decision Tree Question 2 [Storyboard_CT_VB20_Preview_Series_Sim_02_03_inserted.mp3] From the available answer options, select Arrhythmic . Please select Arrhythmic to continue. Answer Heart Rate Variability Decision Tree Question 3 [Storyboard_CT_VB20_Preview_Series_Sim_02_04_inserted.mp3] In the Recon Ranges area, the Preview Series recon job will immediately be available as first recon job selectable. There is a specific icon for the Preview Series recon job. In addition, make sure you have taken the following initial steps: You have performed your cardiac workflow as usual until you reach the Reconstruction step. You have opened the reconstruction parameters by double- clicking a recon job icon in the Recon Ranges area. Initial Steps [Storyboard_CT_VB20_Preview_Series_Sim_02_05_init_steps.mp3] In addition, make sure you’ve taken the following initial steps : You’ve performed your cardiac workflow as usual until you reach the Reconstruction step . You’ve opened the reconstruction parameters by double-clicking a recon job icon in the Recon Ranges area. Identify Slice Position for the Preview Series Recon Job [Storyboard_CT_VB20_Preview_Series_Sim_02_02.mp3] After cardiac image acquisition, identify the slice for which you’d later like to perform the Preview Series reconstruction. You need to select the slice with motion artifacts to later create the different cardiac phase reconstructions. To do so, scroll through the images directly in the image segment by using your mouse wheel. In parallel, observe the dotted line in the topogram segment, which corresponds to the slice you’re viewing in the image segment. Performing the Preview Series reconstruction afterwards enables you to visually detect the cardiac phase and image of this slice with least motion. Select the Preview Series recon job to continue. Select the Preview Series Recon Job [Storyboard_CT_VB20_Preview_Series_Sim_02_07_slct_ps_icon.mp3] Now select the icon for the Preview Series recon job. Please remember: Since you’ve answered the Heart Rate Variability decision tree question with Arrhythmic, the Preview Series recon job icon is the first one in the line of recon jobs. Select it to continue. Please select the Preview Series recon job to continue. Move the Preview Slice to the Desired Position [Storyboard_CT_VB20_Preview_Series_Sim_02_04.mp3] The system automatically positions the preview slice inside the scan range using FAST Planning. With the help of the dotted image position line in the topogram segment, move the preview slice to the desired position that you’ve identified before. Select the Physio Recon tab to continue. Select Physio Recon Tab [Storyboard_CT_VB20_Preview_Series_Sim_02_09_slct_pr_tab.mp3] To take a look at possible adjustments of the Preview Series recon parameters, select the Physio Recon tab now. Please select the Physio Recon tab to continue. Select ms to continue. Selectable Recon Phase Units > ms Selection [Storyboard_CT_VB20_Preview_Series_Sim_02_06.mp3] On the Physio Recon tab, let’s see the Recon Phase Units that you can select to reconstruct your desired cardiac phase: Percentage and milliseconds are available in the Recon Phase Units drop-down. Select milliseconds to continue. Please select ms to continue. Select 50 to continue. Select Recon Phase Step [Storyboard_CT_VB20_Preview_Series_Sim_02_07.mp3] As a next step, select the steps in milliseconds you’d like your Preview Series reconstruction to take. In the drop-down of the Recon Phase Step column, steps of 20, 50, 100 and 200 milliseconds are available. Select 50 to continue. Please select 50 to continue. Select Single Recon Phases [Storyboard_CT_VB20_Preview_Series_Sim_02_08.mp3] And finally, from the Recon Phase column drop-down, you select the single recon phases in 50 ms steps that you’d like the system to reconstruct after starting the Preview Series reconstruction. As a default, the single recon phases are all selected. Please note: After tomo scans, the system automatically selects only phases that are reasonable for this scan. The button Deselect All in the drop-down makes deselection less time consuming for you, when you know you only want to select a few phases for reconstruction. Selectable Recon Phase Units > % Selection [Storyboard_CT_VB20_Preview_Series_Sim_02_09.mp3] Now let’s also take a look at what the options are, if you’ve selected the Recon Phase Unit percentage. Select 10 to continue. Select Recon Phase Step [Storyboard_CT_VB20_Preview_Series_Sim_02_10.mp3] In the drop-down of the Recon Phase Step column, then steps of 2, 5, 10 and 20 percent are available. For our example that we’ll simulate here, select steps of 10 percent to continue. Please select 10 to continue. Select Single Recon Phases [Storyboard_CT_VB20_Preview_Series_Sim_02_11.mp3] In analogy to the milliseconds selection, you then select the single recon phases in percent steps that you’d like the system to reconstruct after starting the Preview Series reconstruction. As a default, the single recon phases are all selected. Please note: After tomo scans, the system automatically selects only phases that are reasonable for this scan. The button Deselect All in the drop-down makes deselection less time consuming for you, when you know you only want to select a few phases for reconstruction. For our example, select Deselect All. Select Start Recon to continue. Start the Preview Series Recon Job [Storyboard_CT_VB20_Preview_Series_Sim_02_13.mp3] You’re now all set to start the Preview Series reconstruction. To do so, right-click the Preview Series recon job icon. Then select Start Recon from the context menu. Please select Start Recon to continue. Start the Preview Series Recon Job 2 [Storyboard_CT_VB20_Preview_Series_Sim_02_17.mp3] The system is reconstructing the images. View the Reconstructed Images [Storyboard_CT_VB20_Preview_Series_Sim_02_18.mp3] This illustrates how you scroll through the reconstructed images in the image segment. By visual inspection, determine the cardiac phase with the least motion present in the images. In our example, the cardiac phase image of 40% has least motion visible. Keep this value in mind. Select Repeat to continue. Prepare a Single Phase Recon Job [Storyboard_CT_VB20_Preview_Series_Sim_02_19.mp3] Now use this information and perform a Single Phase recon job for the cardiac phase with least motion. To do so, select any recon job icon other than Preview Series and right-click it. Then select Repeat from the context menu to create a new recon job. Please select Repeat to continue. Select the new recon job icon to continue. Prepare a Single Phase Recon Job 2 [Storyboard_CT_VB20_Preview_Series_Sim_02_20.mp3] The system creates the new recon job icon directly to the right of the previously selected one. In addition, the newly created recon job icon changes back to a regular recon job icon. Select it to open and adapt its recon parameters. Please select the new recon job icon to continue. Select Single Phase to continue. Prepare a Single Phase Recon Job 3 [Storyboard_CT_VB20_Preview_Series_Sim_02_21.mp3] In the Recon Type column of the recon parameters panel, select Single Phase from the drop-down menu. Please select Single Phase to continue. Select % to continue. Prepare a Single Phase Recon Job 5 [Storyboard_CT_VB20_Preview_Series_Sim_02_22.mp3] Then move right to the Recon Phase Unit column and select the unit percent. Please select % to continue. Prepare a Single Phase Recon Job 5 [Storyboard_CT_VB20_Preview_Series_Sim_02_23.mp3] Lastly, move left to the Recon Phase column and select its value. Then type in the percentage value of the identified phase image with least motion, for our example 40, and hit enter. Select Start Recon to continue. Start the Single Phase Recon Job [Storyboard_CT_VB20_Preview_Series_Sim_02_24.mp3] To start the Single Phase recon job afterwards, move back over to the selected recon job icon and right-click it. Then select Start Recon from the context menu. Please select Start Recon to continue. View the Reconstructed Single Phase Images [Storyboard_CT_VB20_Preview_Series_Sim_02_25.mp3] The system is reconstructing the images. Once reconstructed, scroll through the Single Phase images to view them by using your mouse wheel. Clear the Preview Series [Storyboard_CT_VB20_Preview_Series_Sim_02_26.mp3] If you want to perform another Preview Series recon job, you first need to clear the previously performed one. This is how to proceed: Right-click the selected Preview Series recon job. Then select Clear Preview Series from the context menu and wait until clearing is done. Afterwards, perform the new Preview Series recon job as previously described in this simulation. Select Recon All to continue. Select Recon All [Storyboard_CT_VB20_Preview_Series_Sim_02_27.mp3] Once you’ve performed your recon jobs and have checked their results, select Recon All to start the reconstructions. Please select Recon All to continue. Select Next to continue. Select Next [Storyboard_CT_VB20_Preview_Series_Sim_02_28.mp3] Then select Next. Please select Next to continue. Select Close to continue. Close the Exam Workflow of Your Patient [Storyboard_CT_VB20_Preview_Series_Sim_02_29.mp3] And lastly, select Close to close the exam workflow of your patient. Please select Close to continue. Congratulations! You have successfully completed the simulation. Click Retry to try the simulation again. To go back to the simulation overview, click Overview. Select Next to read the Disclaimer and exit the learning activity. Retry Overview Next Reconstructed Images in the Patient Browser [Storyboard_CT_VB20_Preview_Series_Sim_02_30.mp3] Back in the Patient Browser, you’ll find the reconstructed images of your patient in the Series area. The situation for the NAEOTOM Alpha class systems is as follows from the VB20 Service Pack 1 onwards: Here, you’ll find the reconstructed images of the Best Phase. And here, the Preview Series recon box that you’ve changed to the single 40% cardiac phase. For Somaris 10 systems other than the NAEOTOM Alpha class: The result series as described above will be available for these systems from the VB20 Service Pack 2 onwards. Instructions Select the icon above to open the table of contents. Click Next to continue. Next Welcome Slide The timeline displays the slide progression. Slide the orange bar backwards to rewind the timeline. Click X in the top right corner to continue. Timeline Change Any Recon Job to a Preview Series and Perform a Reconstruction Interactive simulation: How to create and perform a Preview Series recon job from scratch. Prerequisite: Since you can apply Preview Series only to sequence and spiral scan modes, make sure you have selected a corresponding scan mode. In addition, make sure you have taken the following initial steps: You have selected a cardiac scan protocol. You have performed your cardiac workflow as usual until you reach the Reconstruction step. You have opened the reconstruction parameters by double- clicking a recon job icon in the Recon Ranges area. Prerequisite and Initial Steps [Storyboard_CT_VB20_Preview_Series_Sim_02_01.mp3] This interactive simulation will show you how to create and perform a Preview Series recon job from scratch. Consider the following prerequisite and initial steps. Prerequisite: Since you can apply Preview Series only to sequence and spiral scan modes , make sure you’ve selected a corresponding scan mode. In addition, make sure you’ve taken the following initial steps : You’ve selected a cardiac scan protocol. You’ve performed your cardiac workflow as usual until you reach the Reconstruction step . You’ve opened the reconstruction parameters by double-clicking a recon job icon in the Recon Ranges area. Identify Slice Position for the Preview Series Recon Job [Storyboard_CT_VB20_Preview_Series_Sim_02_02.mp3] After cardiac image acquisition, identify the slice for which you’d later like to perform the Preview Series reconstruction. You need to select the slice with motion artifacts to later create the different cardiac phase reconstructions. To do so, scroll through the images directly in the image segment by using your mouse wheel. In parallel, observe the dotted line in the topogram segment, which corresponds to the slice you’re viewing in the image segment. Performing the Preview Series reconstruction afterwards enables you to visually detect the cardiac phase and image of this slice with least motion. Please select Preview Series to continue. Select Repeat to continue. Create a New Recon Job [Storyboard_CT_VB20_Preview_Series_Sim_02_03.mp3] Now you need to create a new recon job that you’ll later change to a Preview Series recon job. To do so, select and right-click any recon job. Then select Repeat from the context menu. Please select Repeat to continue. Create a New Recon Job 2 [Storyboard_CT_VB20_Preview_Series_Sim_04_04.mp3] The system creates the new recon job icon directly to the right of the previously selected one. In addition, the newly created recon job icon changes back to a regular recon job icon. Now you need to change the Recon Type of the newly created recon job to Preview Series. Select Preview Series to continue. Change New Recon Job to Preview Series [Storyboard_CT_VB20_Preview_Series_Sim_04_05.mp3] From the recon parameters panel, select the Physio Recon tab. Then move over to the Recon Type column, open its drop-down menu and select Preview Series. Please select Preview Series to continue. Change New Recon Job to Preview Series 2 [Storyboard_CT_VB20_Preview_Series_Sim_04_06.mp3] Please note that as soon as you’ve selected the recon type Preview Series, the recon job icon changes to the specific Preview Series recon job icon, and the system automatically positions the preview slice inside the scan range using FAST Planning. Move the Preview Slice to the Desired Position [Storyboard_CT_VB20_Preview_Series_Sim_04_07.mp3] With the help of the dotted image position line in the topogram segment, move the preview slice to the desired position that you’ve identified before. Please select Preview Series to continue. Select ms to continue. Selectable Recon Phase Units > ms Selection [Storyboard_CT_VB20_Preview_Series_Sim_04_08.mp3] Let’s now take a look at possible adjustments of the Preview Series recon parameters. On the Physio Recon tab, let’s first see the Recon Phase Units that you can select to reconstruct your desired cardiac phase: Percentage and milliseconds are available in the Recon Phase Units drop-down. Select milliseconds to continue. Please select ms to continue. Select 100 to continue. Select Recon Phase Step [Storyboard_CT_VB20_Preview_Series_Sim_04_09.mp3] As a next step, select the steps in milliseconds you’d like your Preview Series reconstruction to take. In the drop-down of the Recon Phase Step column, steps of 20, 50, 100 and 200 milliseconds are available. Select 100 to continue. Please select 100 to continue. Select Single Recon Phases [Storyboard_CT_VB20_Preview_Series_Sim_04_10.mp3] And finally, from the Recon Phase column drop-down, you select the single recon phases in 100 ms steps that you’d like the system to reconstruct after starting the Preview Series reconstruction. The button Deselect All in the drop-down makes deselection less time consuming for you, when you know you only want to select a few phases for reconstruction. Selectable Recon Phase Units > % Selection [Storyboard_CT_VB20_Preview_Series_Sim_02_09.mp3] Now let’s also take a look at what the options are, if you’ve selected the Recon Phase Unit percentage. Select 10 to continue. Select Recon Phase Step [Storyboard_CT_VB20_Preview_Series_Sim_02_10.mp3] In the drop-down of the Recon Phase Step column, then steps of 2, 5, 10 and 20 percent are available. For our example that we’ll simulate here, select steps of 10 percent to continue. Please select 10 to continue. Select Single Recon Phases [Storyboard_CT_VB20_Preview_Series_Sim_04_13.mp3] In analogy to the milliseconds selection, you then select the single recon phases in percent steps that you’d like the system to reconstruct after starting the Preview Series reconstruction. For our example, we select all recon phases by selecting the button Select All. The button Deselect All in the drop-down makes deselection less time consuming for you, when you know you only want to select a few phases for reconstruction. Select Start Recon to continue. Start the Preview Series Recon Job [Storyboard_CT_VB20_Preview_Series_Sim_02_13.mp3] You’re now all set to start the Preview Series reconstruction. To do so, right-click the Preview Series recon job icon. Then select Start Recon from the context menu. Please select Start Recon to continue. Start the Preview Series Recon Job 2 [Storyboard_CT_VB20_Preview_Series_Sim_02_17.mp3] The system is reconstructing the images. View the Reconstructed Images [Storyboard_CT_VB20_Preview_Series_Sim_02_18.mp3] This illustrates how you scroll through the reconstructed images in the image segment. By visual inspection, determine the cardiac phase with the least motion present in the images. In our example, the cardiac phase image of 40% has least motion visible. Keep this value in mind. Select Repeat to continue. Prepare a Single Phase Recon Job [Storyboard_CT_VB20_Preview_Series_Sim_02_19.mp3] Now use this information and perform a Single Phase recon job for the cardiac phase with least motion. To do so, select any recon job icon other than Preview Series and right-click it. Then select Repeat from the context menu to create a new recon job. Please select Repeat to continue. Select the new recon job icon to continue. Prepare a Single Phase Recon Job 2 [Storyboard_CT_VB20_Preview_Series_Sim_02_20.mp3] The system creates the new recon job icon directly to the right of the previously selected one. In addition, the newly created recon job icon changes back to a regular recon job icon. Select it to open and adapt its recon parameters. Please select the new recon job icon to continue. Select Single Phase to continue. Prepare a Single Phase Recon Job 3 [Storyboard_CT_VB20_Preview_Series_Sim_02_21.mp3] In the Recon Type column of the recon parameters panel, select Single Phase from the drop-down menu. Please select Single Phase to continue. Prepare a Single Phase Recon Job 5 [Storyboard_CT_VB20_Preview_Series_Sim_04_20.mp3] For our example, make sure you’ve selected the unit percent in the Recon Phase Unit column. Prepare a Single Phase Recon Job 5 [Storyboard_CT_VB20_Preview_Series_Sim_04_21.mp3] Lastly, move over to the Recon Phase column and select its value. Then type in the percentage value of the identified phase image with least motion, for our example 40, and hit enter. Select Start Recon to continue. Start the Single Phase Recon Job [Storyboard_CT_VB20_Preview_Series_Sim_02_24.mp3] To start the Single Phase recon job afterwards, move back over to the selected recon job icon and right-click it. Then select Start Recon from the context menu. Please select Start Recon to continue. View the Reconstructed Single Phase Images [Storyboard_CT_VB20_Preview_Series_Sim_02_25.mp3] The system is reconstructing the images. Once reconstructed, scroll through the Single Phase images to view them by using your mouse wheel. Clear the Preview Series [Storyboard_CT_VB20_Preview_Series_Sim_02_26.mp3] If you want to perform another Preview Series recon job, you first need to clear the previously performed one. This is how to proceed: Right-click the selected Preview Series recon job. Then select Clear Preview Series from the context menu and wait until clearing is done. Afterwards, perform the new Preview Series recon job as previously described in this simulation. Select Recon All to continue. Select Recon All [Storyboard_CT_VB20_Preview_Series_Sim_02_27.mp3] Once you’ve performed your recon jobs and have checked their results, select Recon All to start the reconstructions. Please select Recon All to continue. Select Next to continue. Select Next [Storyboard_CT_VB20_Preview_Series_Sim_02_28.mp3] Then select Next. Please select Next to continue. Select Close to continue. Close the Exam Workflow of Your Patient [Storyboard_CT_VB20_Preview_Series_Sim_02_29.mp3] And lastly, select Close to close the exam workflow of your patient. Please select Close to continue. Congratulations! You have successfully completed the simulation. Click Retry to try the simulation again. To go back to the simulation overview, click Overview. Select Next to read the Disclaimer and exit the learning activity. Retry Overview Next Reconstructed Images in the Patient Browser [Storyboard_CT_VB20_Preview_Series_Sim_02_30.mp3] Back in the Patient Browser, you’ll find the reconstructed images of your patient in the Series area. The situation for the NAEOTOM Alpha class systems is as follows from the VB20 Service Pack 1 onwards: Here, you’ll find the reconstructed images of the Best Phase. And here, the Preview Series recon box that you’ve changed to the single 40% cardiac phase. For Somaris 10 systems other than the NAEOTOM Alpha class: The result series as described above will be available for these systems from the VB20 Service Pack 2 onwards. Question Bank 1 Preview Series in Cardiac Imaging VB20 - USA Hier finden Sie ein paar nützliche Links und Dokumente:
- ct
- vb20
- preview
- series
- reconstruction
- cardiac
- imaging
- retrospective
- prospective
- ecg
- gated
- triggered
- sequence
- acquisition