How to perform 3D acquisition (VExx)

This job aid will demonstrate how to perform an 3D Acquisition and description of 3D Acquisition protocols on VExx application software.  

3D Acquisition (VEXX) job aid Angiography – ARTIS software VEXX An additional job aid is available on PEPconnect to determine the software version of the system. Special 3D acquisition modes are available on ARTIS systems, intended to create 3D images for various applications (vessels and bones). The images will be acquired in equidistant angular spac- ing. Rotation is carried out with predetermined (calibrated) rotational ranges with predefined start and end positions. • If the patient is prone on the table, you must register the patient, HFP or FFP. This will en- sure your imaging is anatomically correct during reconstruction. You may flip your image vertically or horizontally for interventional vs. anatomical viewing. • Collimation may be applied if the collimators do not approach the area of interest too closely. • Zoom sizes vary depending on license availability. • When working with a biplane system, you may sometimes select a protocol that utilizes Twin Spin*. Performing an automatic 3D Acquisition 1. Prepare the patient, stand, C-arm, and table. 2. Prepare the injector, if used. 3. Select the appropriate 3D acquisition protocol via Pilot or exam room. ARTIS Examination Examination Display FL Neuro C-Arm Position Table Fluoro FL(-) Neuro Pulse Rate 10 p/s Detector RDMP & Overlay Acquisition DSA 4 CARE Case Flows Tools Frame Rate 4 f/s Favorites Series Descr. Sys. Pos. Case Flows Display Exam Favorites 4. The system will prompt you to deflect the joystick to perform automatic movements. G G Unrestricted 0 Published by Siemens Healthineers AG © Siemens Healthineers, 2025 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 01/15/2025 | QR700017513 Healthineers 5. Follow the instructions in the message bar to position the region of interest in the Isocenter: a) “3D: Deflect joystick to move to ISO AP position.” – Once you believe you are isocen- ter, tap on fluoro to confirm, then deflect the joystick. b) “3D: Deflect joystick to move to ISO lateral position.” Position your isocenter by lift- ing and lowering the patient table only. If necessary, check the exact height with fluoro. 6. Deflect the joystick to move the C-arm to the start position. G G 7. Deflect Joystick to perform the 3D test run to ensure that no collision will occur. a) “3D test phase: Deflect joystick to start collision check…” G G b) Once C-arm stops moving, the message will read: “3D test phase: Start fluoro to complete test phase.” 8. Perform a brief fluoroscopy for the automatic setting of acquisition parameters — approx. 2 sec. a) The message: “3D test phase: Completed. Stop fluoro” is displayed. b) The message: “3D: Release acquisition for […], s.” c) If an injector is used, an X-ray delay may be needed depending on which spin is se- lected or what anatomy is to be viewed. d) Instruct the patient: “Do not move.” “Hold your breath.”, etc. 9. Start acquisition: Press the exposure release button or pedal and keep it pressed. 10. Release the exposure release when all rotational runs are complete. a) Return the system to the last working position by deflecting the joystick after comple- tion. 11. The 2D projection images are reconstructed to a 3D volume and visualized in the 3D Sharing segment. 3D Sharing a Images Live Ref1 Ref 2 Viewer1 Viewer2 3D Sharing Unrestricted 0 Published by Siemens Healthineers AG © Siemens Healthineers, 2025 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 01/15/2025 | QR700017513 Healthineers Page 2 of 4 3D acquisition protocols* Acquisition Mode Description DR Images are acquired in a single run for native re- constructions. DSA Images are acquired in the mask run and fill run, and subtraction is then performed. DCT Dyna CT Card Cardiac without ECG gating Card ECG Cardiac with ECG gating Perfusion syngo Dynamic Perfusion DynaPBV Neuro Neuro parenchymal blood volume (syngo DynaPBV Neuro) DynaPBV Body Abdomen parenchymal blood volume (syngo DynaPBV Body) Dyna4D 3D DSA with Special rotation angle and rotation time. The series will be used to reconstruct time- dependent vascular volumes that cover both in- flow as well as venous flow. Large Volume Large volume acquired in two off-center rotational runs (syngo DynaCT Large Volume) Large Volume 360 Large volume acquired in one 360 degrees off- center rotational run (syngo DynaCT 360) Sine Spin syngo DynaCT Sine Spin: Volume acquired from Sine Spin Device LAO to RAO or vice versa with a sinusoidal modu- lation in CRAN/CAUD direction *Special 3D protocols are only available with specific system engines/purchasable licenses depending on system options. Unrestricted 0 Published by Siemens Healthineers AG © Siemens Healthineers, 2025 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 01/15/2025 | QR700017513 Healthineers Page 3 of 4 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the soft- ware and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please con- tact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthineers AG 2025 Siemens Healthineers Headquarters Siemens Healthineers AG Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com Unrestricted 0 Published by Siemens Healthineers AG © Siemens Healthineers, 2025 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 01/15/2025 | QR700017513 Healthineers Page 4 of 4

  • 3d range
  • post processing