How to Export Patient Data Symbia Pro.Specta™ System
Symbia Pro.specta™ Systems VA10
This Job Aid shows how to transfer DICOM series and raw data to an off-line folder or network
destination.
Note: This procedure may be necessary when data requests are made by a physician or Service for image quality review.
How to Export Patient Data All Symbia Pro.specta™ Systems VA10 This Job Aid shows how to transfer DICOM series and raw data to an off line folder or network destination. Note: This procedure may be necessary when data requests are made by a physician or Service for image quality review. Transferring DICOM series to an offline folder 1. Navigate to the Patient Browser and select the folder listed under your patient Healthineers Scan 3 = Recon 1 O. Patient Brows Patient Browser Local Data Search by Name, ID, Date, Description and Modality (Ctrl+F) More Filters O Results (12 results, 9.22:58 PM) Patient Modality Study Date and T .. Study Descript ... Exported Study Archived NM 01/01/2021 3:33:32 NM RENAL S. Pro.specta, Parathyroid_X3 F Tc99m Sestamibi Pro.specta, Cardiac_LEHR Stress Rest X3 * M Tc99m Sestamibi CT, NM 01/01/2021 1:34:33. NM CV MYO Pro.specta, xSPECT Bone_T-Spine F Tc99m MDP 25 mCi (918 MBa) CT, NM, SR 01/01/2021 1:07:32 NM BONE W SPECT CT I-123 2, INTEVO 6 O 1-123 2. Click the Export tool icon in the upper right corner Patient Browser Local Data Search by Name ID: Date: Description and Modaily (Chil+F) Q More Filters Open Openwith DICOM Delete Mings Reck Results (12 results, 2 05.34 AM) Series Export Patient Modality Study Date and T ... . Study Descript ... Exported Study Archived Pro.specta, Parathyroid_X3 Te99m Sestamibi · Pro.specta, Cardiac_LEHR_Stress_Rest_X3 Whole Body Delay Topogran 0.70 1120 CT AC 5.00 Or40 93 Delay Desy &SPECT Tc99m Sestamibi CT. NM 01/01/2021 1:34:33 NM CV MYO Pro.specta, xSPECT Bone_T-Spine Tc99m MDP 25 mCi (918 MBq) CT. NM. SR 01/01/2021 1:07:32 .. NM BONE W Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 SIEMENS Master Template Effective Date: 10 Aug 2021 | HILS 2224 Job Aid Effective Date: 02 Jun 2023 | HOOD05162003353937 Healthineers How to Export Patient Data Effective Date: 02 Jun 2023 | HOOD05162003353937 3. In Export Data, uncheck the files you do not want to transfer 4. Select the transfer type from the options listed Note: In this example, we will select File System Export Data ? X 3 Patient Series de Instances CD/DVD . File System Network Pro.specta, xSPECT B ... · CD/DVD . File System Network Report 3 Pro.specta, xSPECT B .. Whole B 2 1 Target capacity sufficient 4 Pro.specta, xSPECT B .. Topogra. Pro.specta, xSPECT B .. CT AC 5 77 Target H:\SiteData\Exportimages Pro.specta, xSPECT B .. Tomo D. Pro.specta, xSPECT B. AC Rec. 1 Back Pro.specta, xSPECT B .. NOAC R Pro.specta, xSPECT B ... AC Rec. Up New P Forward Pro.specta, xSPECT B CT AC 5. 55 Pro.specta, xSPECT B AC Rec .. Protocols_ExportedForArchiving_2022.5.20.9.5 1 ReconWorkDir Pro.specta, xSPECT B AC Re SiteData Pro.specta, xSPECT B .. AC Rec. 3DCam Exportimages Pro.specta, xSPECT B. Zone Ma New Folder Pro.specta, xSPECT B .. AC Rec ... ExportRawData OnlineHelpContent Pro.specta, xSPECT B. Zone Ma 1 teamplay Pro.specta, xSPECT B CT AC 0 348 382.6 MB. 702 Instances Clear List Export Close 5. Click Browse to select the path you want to transfer to CD/DVD File System . Network Target capacity sufficient Target H:\SiteData\Exportimages Properties Compressed Create DICOM file system Add Viewer Image Conversion Enhanced Anonymize as ... Reduced Anonymous SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Healthineers Page 2 of 6 How to Export Patient Data Effective Date: 02 Jun 2023 | HOOD05162003353937 6. Navigate to and highlight the file you want to export the data to and then select Export Export Data ? x Patient Series de. Instances · CD/DVD File System . Network Pro.specta, xSPECT B Report. 3 Pro.specta, xSPECT B Whole B 2 1 Target capacity sufficient Pro.specta, xSPECT B Topogra 1 Pro.specta, xSPECT B CT AC 5 .. 77 Target H:\SiteData\Exportimages Pro.specta, xSPECT B Tomo D 1 Pro.specta, xSPECT B AC Rec 1 Back VP Pro.specta, xSPECT B NOAC R Pro.specta, xSPECT B AC Rec. 1 New Forward Pro.specta, xSPECT B CT AC 5 ... 55 Pro.specta, xSPECT B AC Rec Protocols_ExportedForArchiving_2022.5.20.9.59.1 ReconWorkDir Pro.specta, xSPECT B AC Rec. SiteData Pro.specta, xSPECT B AC Rec. 3DCam Exportimages Pro.specta, xSPECT B Zone Ma. ExportRawData Pro.specta, xSPECT B OnlineHelpContent AC Rec. teamplay Pro.specta, xSPECT B Zone Ma UserData Pro.specta, xSPECT B CT AC O 348 382.6 MB, 702 Instances Clear List Export Close 7. Select Job View at the top right corner of the screen to check the transfer status meduser ? con 1 Job View My Jobs Patient Name Status Total No. Of Obj ... Progress Instances Workflow Label Transfer Type Client Resource User Time Job Data Desci
- export
- patient data
- symbia
- symbia prospecta
- Symbia
- Symbia Pro specta