Hip Unilateral Exam | Position Patient
This video demonstrates how to position a patient for an unilateral hip examination.
Target group: Basic users.
Duration: 4 min. | Audio included.
In this video you will learn how to position the patient for a unilateral hip examination before performing the examination, register the patient fill in the required data and select the program to examine the hip position the patient head first with the head placed and the head cushion at the end of the table. Different positioning workflows apply for unilateral bilateral. Or hybrid hip examinations to perform a unilateral hip scan, move the patient hip more towards the table center by sliding the patient's body to the side. If this position becomes uncomfortable, use positioning AIDS and pads to provide more comfort and a more even table surface. Position the coil under the hip. Connect the coil link and wrap the contour coil around the hip to be examined. Ensure that the region of interest is covered within the side flaps of the coil and fixed the coil with the loop strap. Use additional sandbags to help securing the coil and coil links and keeping them well fixed to the body and in position during the exam. Make sure that the coil links do not protrude from nor fall off the table. They should never touch the patient's body. Use additional pads to improve patient comfort. Check again that you position the patient safely, provide headset and alarm ball for communication. When you want to further optimize the position of the joint, you can put a triangular aid between the patient's feet, ensuring that the toes don't touch. Then use the select and go panel for automatic isocenter positioning. Alternatively, check the position on the ruler to provide manual ISO input at the panel for a correct isocenter positioning. Finally, position the table into the bore at isocenter using the isocenter button and jog wheel. In case you need to position the patient feet first ensure that the feet are placed on the line on the table cover and ensure that the area to be scanned is located inside the 130 centimeter range to enable correct table movement into the isocenter. Hint to perform a unilateral hip exam with Contour S coil on a patient with more than 85 kilograms is not optimal. Therefore, position the patient as you would do for a bilateral hip exam. Use the biomatrix contour L coil and then reduce the field of view to cover the hip of interest.
SIEMENS -h Healthineers SIEMENS SIEMENS SIEMENS . SIEMENS • Scheduler SIEMENS . SIEMENS • SIEMENS Healthineers Healthineers SIEMENS • Healthineers Patients All programs Examination Information Doe. Jane Doe. Jane Home 10 155 Age Spine Coil Coil SIEMENS • Contour S Coil @ Siemens Healthcare GmbH, 2021 Medical Information Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not Please note that the learning material is for training purposes only. Healthineers MAGNETOM Free.Max MACNE MACY (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Alerts Program Selection Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used sales representative for the most current information. as training material only and shall by no means substitute the Operator Manual. Any material used in this Program Selection 10 The reproduction, transmission or distribution of this training or its contents is not permitted without training will not be updated on a regular basis and does not necessarily reflect the latest version of the RF Transmit Mode software and hardware available at the time of the training. express written authority. Offenders will be liable for damages. RF Transmit Mode The Operator Manual shall be used as your main reference, in particular for relevant safety information like All names and data of patients, parameters and configuration dependent designations are fictional and warnings and cautions. examples only. patient Orientation Please note: Some functions in this material are optional and might not be part of your system. All rights, including rights created by patent grant or registration of a utility model or design, are reserved.
- free.max
- freemax
- free max
- hip
- uni
- unilteral
- magnetom free
- patient position
- patient
- positioning
- contour S
- contour M
- contour coil MSK
- contour hip
- hip freemax
- hip exam position
- hip exam positioning
- contour coil hip
- position contour
- position contour coil
- unilateral hip
- position contour
- position contour coil