Hip Bilateral & Pelvis Exam | Position Patient

This video demonstrates how to position a patient for a hip bilateral and pelvis examination.
Target group: Basic users.
Duration: 4 min. | Audio included.

In this video you will learn how to position the patient for a bilateral hip and pelvis examination before performing the examination register the patient fill in the required data and select the program. Different positioning workflows apply for unilateral, bilateral or hybrid hip examinations. For a bilateral hips, can position the patient head first with a spine centered on the table, with a head placed in the head cushion at the end of the table. Placed the coil horizontally at hip level to cover both hips. Ensure that the region of interest is covered within the side flaps of the coil and fixed the coil with the loop strap. It is recommended to use the biomatrix contour L coil. Please note when performing bilateral hip examination the coil must be used in combination with the spine coil that is already integrated in the patient table. For pelvis examinations, position the biomatrix contour L coil in the same way As for bilateral hip examination. For hybrid examinations positioned both the coils for unilateral and bilateral hip examinations first position the coil. Ask for unilateral hip and then position the contour L coil. As for bilateral hip. Secure the coils with the loop strap. Both coils need to be plugged in on the table, in this case 2 coil links might be needed to connect both coils simultaneously to the coil sockets one and two. For all examinations, you can use additional sandbags to help securing and keeping the coil and coil links in position during the exam. It is important to prevent the coil links from protruding from or falling off the table. The coil links should never touch the patient's body. Use additional pads to help positioning the patient in a comfortable manner. Check again that you position the patient safely, provide headset and alarm ball for communication when you want to further optimize the position of the joint, you can put a triangular aid between the patients feet, ensuring that the toes don't touch. Then use the select and go panel for automatic isocenter positioning. Alternatively, check the position on the ruler to provide manual ISO input at the panel for a correct isocenter positioning. Finally, position the table into the bore at isocenter using the isocenter button and jog wheel.

SIEMENS • SIEMENS -h Healthineers Healthineers SIEMENS SIEMENS • Healthineers Scheduler H ealthineers SIEMENS • SIEMENS Healthineers Healthineers SIEMENS SIEMENS • Healthineers Healthineers Doe, Jane Patients 1 Hybrid All programs Examination Information Doe, Jane examination Home Hip Hip 10 Spine Coil contour L Coil 155 SIEMENS @ Siemens Healthcare GmbH, 2021 Medical Information Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not Please note that the learning material is for training purposes only. MAGNETOM Free.Max ;NETOM Free.nax Healthineers (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Alerts Position Pelvis Program Selection Free. Max ee.Max MAGNETOM Free.Max MAGNETOM Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used sales representative for the most current information. as training material only and shall by no means substitute the Operator Manual. Any material used in this Program Selection The reproduction, transmission or distribution of this training or its contents is not permitted without training will not be updated on a regular basis and does not necessarily reflect the latest version of the RF Transmit Mode MAGNETOM Free.Max Free.Max express written authority. Offenders will be liable for damages. software and hardware available at the time of the training. Body Part and Laterality RF Transmit Mode The Operator Manual shall be used as your main reference, in particular for relevant safety information like All names and data of patients, parameters and configuration dependent designations are fictional and examples only. warnings and cautions. patient Orientation All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Please note: Some functions in this material are optional and might not be part of your system. SIEMENS •

  • free.max
  • freemax
  • free max
  • magnetom free
  • hip
  • pelvis
  • bilateral
  • examination
  • contour L
  • BioMatrix contour L
  • BM contour L
  • contour coil MSK
  • contour hip
  • hip freemax
  • hip exam position
  • hip exam positioning
  • contour coil hip
  • position contour
  • position contour coil
  • unilateral hip
  • bilateral hip
  • hybrid hip
  • contour Pelvis
  • pelvis freemax
  • pelvis exam position
  • pelvis exam positioning
  • contour coil pelvis
  • position contour
  • position contour coil
  • hybrid