Head Exam | Position Patient
The video shows you how to position a patient for a head exam.
Target group: Basic users.
Duration: 3 min. | Audio included.
In this video you will learn how to position a patient for a head examination. The head neck coil consists of the following components lever for release upper and lower part. Before performing the examination, register the patient fill in the required data and select the program. The selected GO display provides you further guidance for the different steps of positioning the patient. First position the posterior part of the coil into the patient table. For this, use the slide connect rails. Ensure that the coil is correctly plugged in. Place the pad in the lower part of the coil. Pull the lever to release and remove the anterior part of the coil. Help the patient to get on the patient table and provide instructions on positioning and examination. Position the head of the patient in the posterior part of the coil. Ensure that the shoulders touched the coil base. Placed the head as high as possible to enable the best positioning for head examination. Lock the anterior part of the coil and if necessary, attached the mirror. If your patient needs more space inside the coil, you can remove the posture cushion. Position additional comfort pads under the elbows and legs to increase the patient's comfort during examination. Check again that you position the patient safely and provide the alarm ball. Finally, position the table into the bore at isocenter by using the select and go automatic positioning or the manual mode from the Touch panel when you use select and go always ensure to start from table in home position.
SIEMENS SIEMENS SIEMENS • Healthineers Healthineers SIEMENS • SIEMENS Doe, Jane Healthineers SIEMENS Doe, Jane Healthineers , Jane Home , Jane Home Home Spino Coil spine Coil spine Coil Coil Head Exam SIEMENS • SIEMENS @ Siemens Healthcare GmbH, 2021 Position Patient Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not Please note that the learning material is for training purposes only. Healthineers (yet) be commercially available in your country. Due to regulatory requirements, the future availability of Free.Max said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers For the proper use of the software or hardware, please always use the Operator Manual or Instructions for MAGNETO MAGNETO" AGNETOM Free.Max Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used sales representative for the most current information. as training material only and shall by no means substitute the Operator Manual. Any material used in this The reproduction, transmission or distribution of this training or its contents is not permitted without training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. express written authority. Offenders will be liable for damages. The Operator Manual shall be used as your main reference, in particular for relevant safety information like All names and data of patients, parameters and configuration dependent designations are fictional and warnings and cautions. examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Please note: Some functions in this material are optional and might not be part of your system.
- free.max
- freemax
- free max
- brain exam mri
- brain
- brain exam
- head exam
- head mr
- head mri
- head coil
- patient positioning
- positioning mri
- head position
- head positioning
- brain mri
- brain mr
- brain positioning
- brain position
- head coil
- head coil position
- head coil use
- head neck coil
- head neck coil position
- head neck coil use
- Mr brain exam position