FlexLab™ X Total Lab Automation Weekly Maintenance on the Input/Output Module Job Aid
This job aid provides instructions on how to perform weekly maintenance on the Input/Output Module.
FlexLab TM X Total Lab Automation SIEMENS Healthineers Weekly Maintenance on the Input/Output Module Job Aid Clean the Display Bar on the Input/Output Module Refer to the FlexLab X Total Lab Automation Operators Manual when performing maintenance procedures. 1. Swipe left or right on the touchscreen monitor of the display bar to freeze the screen 2. A 2-minute countdown timer starts (120 seconds) 3. Clean the monitor with a lint-free cloth moistened with 0.1% sodium hypochlorite solution 4. Press and hold the monitor of the display bar to unfreeze it 5. Repeat the above steps to the other monitor of the display bar 120 2 Template Effective Date: 10 Aug 2021 | HILS 2223 1 Effective Date: 28 Mar 2024| QR700003068 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 FlexLab TM X Total Lab Automation SIEMENS Healthineers Weekly Maintenance on the Input/Output Module Job Aid Clean the Worktable on the Input/Output Module Refer to the FlexLab X Total Lab Automation Operators Manual when performing maintenance procedures. 1. Set the Input/Output Module Off-line and Flush Carriers 2. Extract all racks from the lanes 3. If present, move the Panel PC aside to allow the cover to open. Lift up the safety cover by the handle 4. Grasp the robot and manually slide it to the side of the module to allow easy access to the area 5. Clean the worktable with a lint-free cloth moistened with 0.1% 4 sodium hypochlorite solution (bleach) 6. Lower the safety cover 7. Reset the robot. Overview > Cards > select Input/Output > select Diagnostics – Robot > Select Init function button 8. Wait until the robot initializes 9. Set the module On-line te Output , Priority Output 10. Restore racks to the lanes indows Inpeco Rack FlexLab X + Priority Output • Reload only empty racks to output lanes Inpeco Rack FlexLaby 9 TU Uncapped Routine In • Reload to input lanes racks with no empty spaces in rows 2 between samples Effective Date: 28 Mar 2024| QR700003068 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 FlexLab TM X Total Lab Automation SIEMENS Healthineers Weekly Maintenance on the Input/Output Module Job Aid Clean the Robot Gripper on the Input/Output Module Refer to the FlexLab X Total Lab Automation Operators Manual when performing 1822 maintenance procedures. 1. Set the Input/Output Module Off-line and Flush Carriers 2. Extract all racks from the lanes 3. If present, move the Panel PC aside to allow the cover to open. Lift up the safety cover by the handle 4. Grasp the robot and manually move it closer to allow easy access 5. Clean the robot gripper with a lint-free cloth moistened with 0.1% sodium hypochlorite solution 6. Lower the safety cover 7. Reset the robot. Overview > Cards > select Input/Output > select Diagnostics Robot > Select Init function button – 8. Wait until the robot initializes 9. Set the module On-line 10. Restore the racks to the lanes • Reload only empty racks to output lanes • Reload to input lanes racks with no empty spaces in rows between samples 3 Effective Date: 28 Mar 2024| QR700003068 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 FlexLab TM X Total Lab Automation SIEMENS Healthineers Weekly Maintenance on the Input/Output Module Job Aid Clean the Input/Output Module Racks Refer to the FlexLab X Total Lab Automation Operators Manual when performing maintenance procedures. 1. Remove racks from the lanes 2. Remove all sample tubes from the racks 3. Clean the racks with a lint-free cloth moistened with 0.1% sodium hypochlorite solution 4. Allow racks to air-dry before returning them to the Module 5. Restore racks to the lane 4 Effective Date: 28 Mar 2024| QR700003068 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 SIEMENS Healthineers Please note this learning material is for training purposes only. FlexLab TM X Automation is manufactured by Inpeco and distributed by Siemens Healthcare Diagnostics Inc. FlexLab is a trademark of Inpeco SA. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Siemens Healthineers HQ I Siemens Healthineers AG Siemensstr. 3 91301 Forchheim Germany Phone: +49 9191 18-0 siemens-healthineers.com 5 Effective Date: 28 Mar 2024| QR700003068 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024
- automation
- flexlab
- track