FlexLab™ X Total Lab Automation Purge the Automation System of Sample Tubes Job Aid
This job aid provides instructions on how to remove all samples from the Automation System (purge operation).
FlexLab TM X Total Lab Automation SIEMENS Healthineers Purge the Automation System of Sample Tubes Job Aid 2 Purge the Automation System of Sample OVERVIEW ROUTINE UTILITY SYSTEM SETUP AUTOMATION Sid V 5001 ) [Inpeco FSE Tubes START PAUSE CURRENT STATE fxxgui 3 This procedure describes how to remove all samples Automation System ANALYZERS SOFTWARE/FIRMWARE MAINTENANCE EXERCISE UTILITIES LIS DIRECT COMMAND SDO R/W from the Automation System (purge operation). Commands 4 1. Insert empty racks in IOX lanes configured for Priority Output START PAUSE SHUTDOWN PURGE FLUSH LOGS RELOAD CONFIGURATION FROM FILE SAMPLE CHECK SEND TEST E-MAIL ALL ANALYZERS Backup 2. In the Automation menu, press the System button log BACKUP ... RESTORE ... 3. Select the Utilities tab Reserved A 4. Press the Purge button FAKE ERROR SAMPLE DATABASE SAMPLE LIS RESET HEMATOLOGY ISLAND RACKS DELETE MOTOR LOGS RELOAD LAYOUT 5. Type YES to confirm and press Save 6. The Automation System starts unloading the sample tubes to the IOM Priority Output racks 7. Remove all full Priority Output racks and remove the sample tubes 8. Reinsert the empty racks in the Priority Output Template Effective Date: 10 Aug 2021 | HILS 2223 1 lanes and repeat until all samples have been Effective Date: 28 Mar 2024 | QR700002750 unloaded from the track Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 SIEMENS Healthineers Please note this learning material is for training purposes only. FlexLab TM X Automation is manufactured by Inpeco and distributed by Siemens Healthcare Diagnostics Inc. FlexLab is a trademark of Inpeco SA. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Siemens Healthineers HQ I Siemens Healthineers AG Siemensstr. 3 91301 Forchheim Germany Phone: +49 9191 18-0 siemens-healthineers.com 2 Effective Date: 28 Mar 2024 | QR700002750 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024
- automation
- flexlab
- track