FlexLab™ X Total Lab Automation Perform a Controlled Power Shutdown Job Aid

This job aid provides instructions on how to perform a controlled shut down to perform routine maintenance and troubleshooting diagnostic procedures. 

FlexLab TM X Total Lab Automation SIEMENS Healthineers Perform a Controlled Power Shutdown Job Aid Perform a Controlled Power Shutdown A OVERVIEW ROUTINE UTILITY SYSTEM SETUP AUTOMATION Sid 5001 . Q Inpeco FSE START PAUSE CURRENT STATE A controlled power shutdown is used to perform routine fxxqui B maintenance and perform troubleshooting diagnostic procedures. Automation System ANALYZERS SOFTWARE/FIRMWARE MAINTENANCE EX UTILITIES LIS DIRECT COMMAND SDO R/W Remove all samples from the Automation System. If necessary, C 1. Commands purge the Automation System of sample tubes O START PAUSE SHUTDOWN PURGE FLUSH LOGS RELOAD CONFIGURATION FROM FILE SAMPLE CHECK SEND TEST E-MAIL ALL ANALYZERS 2. Remove all samples from the Centrifuge Module Backup 3. Set all Automation Modules and Interface Modules to Offline BACKUP ... RESTORE ... Reserved 4. Unlock and remove all racks located in IOM lanes A X 5. Shutdown the Automation Software: FAKE ERROR SAMPLE DATABASE SAMPLE LIS RESET HEMATOLOGY ISLAND RACKS DELETE MOTOR LOGS RELOAD LAYOUT A. In the Automation menu, press the System button B. Select the Utilities tab C. Press the Shutdown button D. Press Yes to confirm E. Wait until Automation Software is closed Procedure continued on next page Template Effective Date: 10 Aug 2021 | HILS 2223 1 Effective Date: 28 Mar 2024 | QR700002750 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 FlexLab TM X Total Lab Automation SIEMENS Healthineers Perform a Controlled Power Shutdown Job Aid Perform a Controlled Power Shutdown, continued 6. If the Automation System is equipped with a Panel PC, access all Panel PCs and turn them off as follows: a. Logout from the Automation Software b. Turn off the Panel PC 7. Turn off the power to the Automation System. Locate the main A 400 V ~ power switch to the Automation System and remove the panel to access 8. Turn the main power switch to the left, toward position A 9. If the Automation System is equipped with more than one Main Power Switch, repeat step 8 for each power switch 10. Replace the panel 2 Effective Date: 28 Mar 2024 | QR700002750 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 SIEMENS Healthineers Please note this learning material is for training purposes only. FlexLab TM X Automation is manufactured by Inpeco and distributed by Siemens Healthcare Diagnostics Inc. FlexLab is a trademark of Inpeco SA. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Siemens Healthineers HQ I Siemens Healthineers AG Siemensstr. 3 91301 Forchheim Germany Phone: +49 9191 18-0 siemens-healthineers.com 3 Effective Date: 28 Mar 2024 | QR700002750 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024

  • automation
  • flexlab
  • track