FlexLab™ X Total Lab Automation Monthly Maintenance on the Aliquoter Module Job Aid
This job aid provides instructions on how to perform monthly maintenance on the Aliquoter Module.
FlexLab TM X Total Lab Automation SIEMENS Healthineers Monthly Maintenance on the Aliquoter Module Job Aid Clean the Rollers and Printhead on the 2 Aliquoter Module Refer to the FlexLab X Total Lab Automation Operators Manual when performing maintenance procedures. 1. Set the Aliquoter Module Off-line and Flush Carriers 2. Open the indicated module cover O 3. Open the printer and remove the tubes inside 3 DEL 4. Load the removed tubes into the Secondary Tubes box 4 * This procedure is continued on the next slide. Template Effective Date: 10 Aug 2021 | HILS 2223 1 Effective Date: 28 Mar 2024| QR700003068 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 FlexLab TM X Total Lab Automation SIEMENS Healthineers Monthly Maintenance on the Aliquoter Module Job Aid Clean the Rollers and Printhead on the Aliquoter Module, continued 7 5. Clean all rollers (indicated with 5 arrows in the image) with a lint-free cloth lightly moistened with 70% isopropyl alcohol solution 6. Extract the printhead: grasp the printhead, push it downwards and then outwards to remove it 7. Clean the printhead with a lint-free 6 cloth lightly moistened with 70% isopropyl alcohol solution 8. Restore the printhead to its original position 9. Close the printer 10. Close the module cover 11. Set the module On-line 2 Effective Date: 28 Mar 2024| QR700003068 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 FlexLab TM X Total Lab Automation SIEMENS Healthineers Monthly Maintenance on the Aliquoter Module Job Aid Clean the Tip Waste Tube on the Aliquoter Module Refer to the FlexLab X Total Lab Automation Operators Manual when performing maintenance procedures. 2 1. Set the Aliquoter Module Off-line and Flush Carriers 2. Open the indicated module cover 3. Clean the waste tube with 0.1% sodium hypochlorite solution 4. Rinse with a cloth moistened with water and wait for the area to dry 5. Close the module cover 6. Open the waste drawer 7. Clean the end of the waste tube with 0.1% sodium hypochlorite solution 6 8. Rinse with a cloth moistened with water and wait for the area to dry 9. Close the waste drawer 10. Set the module On-line 3 Effective Date: 28 Mar 2024| QR700003068 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 FlexLab TM X Total Lab Automation SIEMENS Healthineers Monthly Maintenance on the Aliquoter Module Job Aid Clean the Pipettor Tubing on the Aliquoter Module Refer to the FlexLab X Total Lab Automation Operators Manual when performing maintenance procedures. 1. Set the Aliquoter Module Off-line and Flush Carriers 2. Put the pipettor into cleaning position: A. Select Overview and select Aliquoter B. Select Diagnostics – Pipettor C. Select Approach in the pop-up, select Pipettor Cleaning and 4 confirm 3. Open the module cover 4. Pull up and carefully clean the pipettor tubing with 0.1% sodium hypochlorite solution 5. Rinse with a cloth moistened with water and wait for the area to dry 6. Close the module cover 7. Set the module On-line 4 Effective Date: 28 Mar 2024| QR700003068 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 SIEMENS Healthineers Please note this learning material is for training purposes only. FlexLab TM X Automation is manufactured by Inpeco and distributed by Siemens Healthcare Diagnostics Inc. FlexLab is a trademark of Inpeco SA. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Siemens Healthineers HQ I Siemens Healthineers AG Siemensstr. 3 91301 Forchheim Germany Phone: +49 9191 18-0 siemens-healthineers.com 5 Effective Date: 28 Mar 2024| QR700003068 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024
- automation
- flexlab
- track