Siemens Healthineers Academy

FlexLab™ X Total Lab Automation Configurations Job Aid

This job aid provides instructions on how to complete configurations on the FlexLab™ X Total Lab Automation.

FlexLab TM X Total Lab Automation SIEMENS Healthineers Configurations Job Aid ROUTINE UTILITY ArTIIn ALITAAMATION . Enna Maintenance overdue Lane and Label Configuration - mlOM1 / 1 (1) 2 orted Output) Change an Input/Output Module 10Ms START PAUSE 1 2 TRAY CONFIGURATION LANE CONFIGURATION LABEL CONFIGURATION 11 Lane Configuration 1 + Input lanes In the Overview screen, trays, lanes, and labels 3 4 1 - Lowest Input 1 Routine Input TO ASAP Input 1 + STAT Input are configured. mIOM1 / 1 10 Skip Centrifuge Lowest Input 1º Skip Centrifuge Routine Input O10 Skip Centrifuge ASAP Input +TO Skip Centrifuge STAT Input BIM1 / 1 To change an Input/Output Module lane D D configuration: TU Uncapped Lowest Input TU Uncapped Routine Input OU Uncapped ASAP Input TU Uncapped STAT Input MIOM2 / 2 D TU Sealed Lowest Input TU Sealed Input OU Sealed ASAP Input ++U Sealed STAT Input 1. In the Overview screen, select the lane Immulite 2000 / 1 (without rack inserted) to be configured D Long Term Storage Input LT Dynamic +14 Shaken Uncapped STAT Input To, Shaken Capped STAT Input 2. Select Lane Configuration tab Cancel Rese Output lanes 3. Select the appropriate or desired lane Sorted Output Generic Sorted Output Incomplete Output LV Complete Output configuration type 4 + Priority Output ¿ T Dynamic 4. The selected option is displayed 5. Select Save Configuration 5 X SAVE CONFIGURATION CLEAR LABELS CLOSE MANAGE SORTING TESTS Template Effective Date: 10 Aug 2021 | HILS 2223 1 Effective Date: 28 Mar 2024 | QR700002750 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 FlexLab TM X Total Lab Automation SIEMENS Healthineers Configurations Job Aid 1 OVERVIEW ROUTINE UTILITY SYSTEM SETUP AUTOMATION Sid V 5001 Inpeco FSE A START PAUSE CURRENT STATE Add Sorting Tests to the fxxgui = Input/Output Module Lanes Automation Tests 2 SORTING TESTS ALIQUOTA TEST ALIQUOTA TUBES DEFAULT PROG TEST CODES To add sorting tests to the lanes of the 4 *Enter Sorting Lanes separated by blanks (e.g. 1 2A 3C 4B) or S for Storage or P for Parking or Rx where x is the ROM number ADD DELETE SAVE or Bx where x is the BOM number or SPx for temporary parking where x is the Storage Module number DELETE ALL Input/Output Module: 3 Available Lanes: 1-1, 1-2, 2-1, 2-2 ASTM Code Test Code Test Description Sorting Lanes * Tube Processing STORE-A STORE-A Any process and Store S A 1. In the Setup menu, select Configurator STORE-C STORE-C Centrifuge and Store S C STORE-D STORE-D (Decap, Seal,) Store S SC STORE-N STORE-N (Seal and) Store S N > Automation Tests SORT-C SORT-C Centrifuge and sort 01 C SORT-D SORT-D Decap and sort 01 02 D SORT-E SORT-E Priority Output Rack P E SORT-P SORT-P 03 P 2. Select the Sorting Tests tab Priority Sorting SORT-S SORT-S Seal/Recap and Sort S S SORT-IOM SORT-IOM Centrifuge and sort 1 C #SC016 #SC016 TEST SORTING OVERDUE 1-1 P PARK D 3. Select the Add button to insert a new PARK PARK P #SCOOE #SCOOE #SCOOE 1 A SORT-X SORT-X Uncapped, A1CE_W 245 P Sorting Test DES DES Desealer and sorting-IOM 12 X 4. When done, select the Save button 2 Effective Date: 28 Mar 2024 | QR700002750 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 FlexLab TM X Total Lab Automation SIEMENS Healthineers Configurations Job Aid 1 OVERVIEW ROUTINE UTILITY SYSTEM SETUP AUTOMATION Sid V ) 5001 v Q Inpeco FSE A START PAUSE CURRENT STATE Configure the Rack Input Module fxxgui 11 3 Automation Configuration 1. Select Automation Calendar CAP COLOR COMPUTER CONSUMABLES DATABASE EMPTY CARRIER LAYOUT LIS LOG FILES OVERLOAD SETTINGS VISION SYSTEM Working Days : Monday to Sunday 2. Select Configuration Holidays: 1/1 25/12 4/7 PRINT EXPORT CSV Laboratory Name Value 3. Select Settings Laboratory: IOM Automatic Printing of Priority Output Racks NO IOM Automatic Printing of Sorted Output Racks NO IOM Axis X and Y Scale 1/1000 mm 4. Select the parameter RIM X Sample Tube IOM Generic Sorting Tests IOM Helps Storage to Unload Tubes Configuration (where “X” is the instance of Switch Config NO Save Config IOM Immediately Park Samples Without Test Orders NO IOM Instance for Complete Tubes without Analyzer Tests (0 ... 9) 0 IOM Instance for Tubes without Test Orders (0 ... 9) 2 the RIM) IOM Samples Without Test Orders Go to Incomplete Racks NO IOM Samples Without Test Orders Overdue Timeout (mins) (1 ... 10000) 5 IOM Send Conflicting Sorting Tubes to PO Racks NO IOM Send Duplicate Tubes to PO if Sorting Rack Unavailable NO 5. Select the type of configuration for the IOM Send Error Tubes to PO if Sorting Rack Unavailable YES IOM Send Tubes to PO if Sorting Rack Unavailable NO Module IOM Sorting Lane for QC Sample Errors IOM Sorting Lane for STAT Sample Errors IOM Tubes to Complete Rack if Sealer unavailable YES IOM Tubes to Incomplete Rack if Centrifuge unavailable Keep on Track IOM Tubes to Incomplete Rack if Decapper unavailable NO IOM Tubes to Incomplete Rack if Sealer unavailable NO Minimum Empty Carriers on Main Track (0 ... 9999) 0 4 Prioritize ASAP Samples NO RIM 1 Sample Tube Configuration Skip Centrifuge 5 RIM Sample ID Prefixes For Pre-Spun Tubes Routine Input Stop Loading Tubes if Insufficient Empty Carriers Skip Centrifuge Storage Default Dwell Time Storage Full Threshold (Tubes) (1 ... 15360) Uncapped Storage Reset Dwell Time YES 3 Effective Date: 28 Mar 2024 | QR700002750 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 SIEMENS Healthineers Please note this learning material is for training purposes only. FlexLab TM X Automation is manufactured by Inpeco and distributed by Siemens Healthcare Diagnostics Inc. FlexLab is a trademark of Inpeco SA. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Siemens Healthineers HQ I Siemens Healthineers AG Siemensstr. 3 91301 Forchheim Germany Phone: +49 9191 18-0 siemens-healthineers.com 4 Effective Date: 28 Mar 2024 | QR700002750 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024

  • automation
  • flexlab
  • track