FlexLab™ X Total Lab Automation As Needed Maintenance on the Bulk Input Module Job Aid
This job aid provides instructions on how to perform as needed maintenance on the Bulk Input Module.
FlexLab TM X Total Lab Automation SIEMENS Healthineers As Needed Maintenance on the Bulk Input Module Job Aid Empty the Discarded Tubes Container on the Bulk Input Module Refer to the FlexLab X Total Lab Automation Operators Manual when performing maintenance procedures. 1. Open the module front panel to access the Bulk Input Module discarded tubes container 2. Remove the discarded tubes container 3. Inspect the container and ensure that the capped tubes are closed and their labels are very adherent to the tube and without wrinkles 4. If the tubes inside the container are in a good state, try to reload them on the Bulk Input Module. If the tubes are discarded again, load the sample tubes to an Input Module 1 5. Once the discarded tubes container is empty, put it back in its position 6. Close the front panel of the Bulk Input Module Template Effective Date: 26 Mar 2025 | QR700020784 1 Effective Date: 17 Oct 2025| QR700028931 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 FlexLab TM X Total Lab Automation SIEMENS Healthineers As Needed Maintenance on the Bulk Input Module Job Aid Clean the Backlight Plane on the Bulk Input Module Refer to the FlexLab X Total Lab Automation Operators Manual when performing maintenance procedures. YASKAWA Should the backlight plane get dirty due to an unforeseen event, such as a spill, follow these steps to clean. 1. Set the Module Off-line 2. Open the module cover by the handle 3. Locate the backlight plane and clean it with a lint-free cloth moistened with 0.1% sodium hypochlorite solution 4. Close the module cover 5. Set the module on-line 3 Template Effective Date: 26 Mar 2025 | QR700020784 2 Effective Date: 17 Oct 2025| QR700028931 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 Please note that this learning material is for training purposes only. SIEMENS Healthineers All trademarks are the property of their respective owners. Product availability may vary from country to country and is subject to varying regulatory requirements. Please contact your local representative for availability. FlexLab TM X is manufactured by Inpeco and distributed by Siemens Healthcare Diagnostics Inc. FlexLab TM is a trademark of Inpeco SA. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product-related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration-dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Siemens Healthineers Headquarters Siemens Healthineers AG Siemensstr. 3 91301 Forchheim, Germany Phone: +49 9191 180 siemens-healthineers.com Template Effective Date: 26 Mar 2025 | QR700020784 3 Effective Date: 17 Oct 2025| QR700028931 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025
- automation
- flexlab
- track