epoc® Blood Analysis System with NXS Host Performing a Whole Blood Test Video
This video will show you the steps on how to perform a whole blood test on the epoc® Blood Analysis System with NXS Host.
This video will introduce you to the steps on how to perform a whole blood test on the Epoch blood analysis system with NXS host. To perform a whole blood test, you will need the following supplies, the Epoch reader, the Epoch NXS host, a new Epoch test card, and a syringe. Please wear the proper personal protective equipment when handling any patient blood specimens. To start, press the power switch to turn on the Epoch reader. The power LED will turn green, indicating the Epoch Reader is on and ready for use. Next, turn on the host by pressing the power button located on the upper right side of the host. Sign in to the epoch host using your sign in user ID and password or by scanning your user ID bar code. When the host connects to a selected reader, the test status indicator will turn solid green. This means the reader is ready for use. Next, the host will display a test screen. The screen will then show Insert new test Card. Select a test card and remove it from the pouch. Be sure to not touch the sensor modules contact surface or the blood sample entry port. Hold the test card facing the sample port upwards. Insert the test card into the card slot of the reader by firmly pushing it in using a smooth single motion. This will enable the bar code on the card label to be read correctly by the epoch reader. Be sure to lock the card into place. Once the card is locked into place, the reader will beep once. The host screen will then display the card lot number and the test status indicator light will start flashing green. Next, the host screen will show that the system is calibrating. Do not inject the sample into the card until calibration is complete. The calibration process takes approximately 165 seconds to complete. Once calibration is complete, the system will beep twice. The host will display an inject sample message and countdown timer on the screen. Next, inject the sample using a syringe into the port on the test card. Hold the syringe barrel vertically between fingertips and thumb and perpendicular to the test card. Using slight downward pressure, secure the syringe's lure tip into the blood sample entry port of the test card. Rotate the syringe up to 1/4 turn to ensure a good seal while maintaining downward pressure. Use the index finger of the other hand to steadily depress the syringe plunger with a single, smooth, continuous motion until prompted to stop. The reader will beep and the test status indicator will flash green. If the sample is injected into the card too soon or too late, an error message will appear and the system will abort the test. While the sample is being analyzed, enter the Patient ID into the host. Once the information has been entered into the host, a check mark will be visible on the blue circle and the Patient ID is shown in the action bar. Patient ID can also be viewed in the Edit Test Details section of the software. Answer Yes or no to the Hemodilution question. Next, choose Select Test in the software. Select the test panel from the list. Select the proper buttons to customize the test options. Other patient information such as patient age, gender, and height can be entered into the Edit Test Details section. If temperature correction is needed, that information can be entered into this area as well. Once complete, select close in the software. The host will display analyzing sample when the test is in process. When the analysis is complete, the results will display on the host screen. If any data is missing, the missing required data message will appear on the screen, prompting the operator to enter the missing data. In order to view the test results, remove the test card. Once the results are displayed on the host screen, discard according to laboratory protocol. Select the close and Transmit button to save the test data and close the test window. Select the Report Results button to document who the test results have been reported to. Select the Reject test button to reject the results. This completes the video on how to perform a whole blood test on the EPOCH blood analysis system with NXS host.
52 2020-05-29 50012187-02 510747 00 83% 84% 12 123 1234 7123 2021-12-24 200 20 89 100% 7.069 67.2 96.3 19.4 -10.8 -7.5 93.2 114 2.2 1.40 80 20.5 14 17 <10 epoc® Blood Analysis System with NXS Host Performing A Whole Blood Test Video BLOOD ANALYSIS CE epoc BLOOD AN REF 10736515 Na+ K+ p02 Hct LOT 10-19347-20 SN 510747 Epocal Inc. Ottawa, ON Ca IVD pH Glu pC02 Lac Ca++ Crea TC02 LOT SN Ottawa, ON Canada siemens.com/epoc 11-Aug-21 14:10 Version 4.6.4 About User ID SIGN IN q w e ABC 45 6 7 a s Connecting. Do not insert card. You can edit Test Details now. Edit Test Details Patient ID * Required to view results Scan or enter Patient ID Select Hemodilution * 3 4 a s d Configuring Rdr26415. Do not insert card 2 3 4 card. 10s remaining 1-Aug-21 14:16 card. 1s remaining. a sd Insert new Test Card. Show me how Scan q w REF] 10736515 Crea LOT 11-21190-40 BUN SN 606740 Ca+ + Cr 11-Aug-21 14:35 X Blood Test: Rdr26415 Show less 78% battery Test Card inserted. Enter patient information Enter sample information wertyu n m Lot 11-21190-40 Calibrating. Do not inject sample 02:53 remaining v b qwertyu z x cv b 1 2 3 11-Aug-21 14:58 00:02 remaining qwerty Inject Sample 07:29 remaining hide 3 m on 11-Aug-21 15:56 Analyzing sample 00:32 remaining 12 3 4 5 6 7 8 9 0 34 5 6 7 8 9 0 Next emodilution * o view results Select Sample Type Select tests Select Hemodilution Patient 1234 Yes No Patient temperature, age, gender, height Required fields completed Venous Mixed-venous Capillary Cord Cord Arterial Cord Venous Unknown Arterial Sample Type Clear Draw site, Allen's test Enter respiratory information Glu, Lac, BUN, Crea) Enter Comments Gases+ Electrolytes eMP Custom Selection pH Chem+ Ca+ Meta+ Comments tests sample information All Delivery system, Mode, FiO2, Flow, RQ, .. 11-Aug-21 15:57 Se Ente temperature, age, gender, height respiratory information Calculating Results. SAVE & CLOSE REPORT RESULTS iQC cnc BE(ecf) Ca++ iOc TCO BE(b) ShOW 26-Jun-25 16:00 Patient 12345 CLOSE & RE JECT TRANSMIT TEST mmol/L AGapK show wer s d BLOOD ANALYS Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Siemens Healthcare GmbH 2021 SIEMENS Healt Healthineers
- epoc
- blood
- test
- nxs
- analysis
- whole
- gas