Emergency Shutdown & Restart of the CT system
This short tutorial video will demonstrate the steps to perform an emergency shutdown and restart of your CT system.
Coming U in this video is an explanation of how to shut down and restart the system in the event of an emergency for somatom xseed somatom X site somatom go and neotoma alpha. In the event of an emergency, all system movements and radiation can be interrupted by pressing the stop or emergency off key. You can find them in the following places. The on off switch can be found on the Smart Connector board or in the gantry connector box, which are located at the gantry stand. Emergency off key on the wall. If it is installed. The line connection box. LCB power switch. If an LCB is installed. There is a switch. On off button on the Smart Connector board or in the gantry connector box. Both are integrated in the gantry stand. The position is different between scanner models. In some atomic seed, some Otomax site and neotoma alpha, the Smart Connector board is found on the side of gantry base. In Somatom go, the box is found on the side of the gantry. The. Switch is inside this box. You can find the stop keys in the following places. At the gantry. On the control box. On the Halo or Halo cover plate. The Halo is optional only for somatom gotop somatom goal somatom go up and somatom go now. The Halo cover plate is optional only for somatom GO family scanner. At the gantry back. This is optional only for neotoma alpha somatom exceed and somatom X site. Press a stop key in the event of any unintentional system movement, and in any hazardous situation. Press an emergency off key if the system does not respond to the stop keys in any hazardous situation. Shut down the system immediately. If system malfunctions are detected and notify customer service at Siemens HEALTHINEERS. The emergency off key interrupts the power supply to the system. Data can be lost. The computers can be equipped with an optional uninterruptible. Power supply. In addition, the entire system can be connected to the hospital's emergency. Power supply. The emergency off button interrupts the power supply to the system. Please be aware that a forced shutdown may cause data loss or data inconsistency in open workflows at any connected client. While scanning you can stop the scanning and movement by pressing the stop key. Always observe the patient directly. Press the nearest stop key in the event of danger. You are informed that the. System will shut down and a. Timer dialog. Is displayed. After you press one of the stop keys. You can cancel shutdown by pressing one of the stop keys a second time or clicking no. To switch on the system again, press one of the following buttons. The on off switch and the Smart Connector board or gantry connector box. The wall switch on button if installed. The system will need to start. Up twice for it to operate normally after the main power has been restored in the following two scenarios. The system has an LCB, but no. UPS or an exhausted UPS. And the input power of the LCB is disconnected. The system has an LCB and a UPS and after the input power of the LCB is disconnected, the emergency power off button is pressed. To ensure the safe operation of the. System a checkup procedure should be carried out to correct any irregularities and to ensure the detector is at the correct operating temperature. This checkup procedure should be carried out. Before any patient examination, every time there is a forced shutdown or a. Stop. Key has been pressed. In addition, please make sure that the gantry and table moves safely and correctly.
10 11 12 SIEMENS Healthineers. Emergency Shutdown and Restart of the System Somaris 10 CT scanners Unrestricted @ Siemens Healthineers, 2022 Effective Date: 08/01/2022 | HOOD05162003290386 This video will demonstrate: ency system shutdown and restart Introduction to the video How to perform an emergency system shutdown and restart for SOMATOM X.ceed, SOMATOM X.cite, SOMATOM go .*, and NAEOTOM Alpha. * SOMATOM go.Top, SOMATOM go.All, SOMATOM go.Up and SOMATOM go.Now, SOMATOM go.Sim and SOMATOM go.Open Pro. System components EMERGENCY OFF keys In the event of an emergency, all system movements and radiation can be interrupted by pressing the STOP or The On/Off switch can be found on the smart connector board or in the gantry connector box which are located at the gantry stand. Smart connector board1 Gantry connector box2 1: only for NAEOTOM Alpha, SOMATOM X.ceed, and SOMATOM X.cite. 2: only for SOMATOM go.Top, SOMATOM go.All, SOMATOM go.Up, SOMATOM go.Now, SOMATOM go.Sim, and SOMATOM go.Open Pro Emergency OFF key on the wall if it is installed. Example of the Example of the LCB The line connection box (LCB) power switch if an LCB is installed. in the gantry stand. The position is different between scanner models. Gantry connector box and smart connector board There is a switch on/off button on the smart connector board or in the gantry connector box. Both are integrated SOMATOM X.ceed, SOMATOM X.cite and NAEOTOM Alpha: The smart connector board is found on the right side of the gantry base. Right side of gantry base Smart connector board SOMATOM go .*: The gantry connector box is found on the right side of the gantry. The switch is inside this box. Right side of gantry Inside of the gantry connector box * SOMATOM go.Top, SOMATOM go.All, SOMATOM go.Up and SOMATOM go.Now, SOMATOM go.Sim, and SOMATOM go.Open Pro. STOP keys Gantry Control Box · Halo (optional)1 or Halo Cover Plate2 Halo (optional) Halo Cover Plate (optional) 1: only for SOMATOM go.Top, SOMATOM go.All, SOMATOM go.Up, and SOMATOM go.Now 2: only for SOMATOM go.Top, SOMATOM go.All, SOMATOM go.Up, SOMATOM go.Now, SOMATOM go.Sim, and SOMATOM go.Open Pro · Gantry back (optional)3 Gantry back (optional) 3: only for NAEOTOM Alpha, SOMATOM X.ceed, and SOMATOM X.cite. Press a STOP key in the event of any unintentional system movement and in any hazardous situation. STOP key Stop and Emergency OFF keys Press an EMERGENCY OFF key if the system does not respond to the STOP keys in any hazardous situation. Emergency OFF key Shut down the system immediately if system malfunctions are detected and notify Customer Service at Siemens The EMERGENCY OFF key interrupts the power supply to the system. Data can be lost. Uninterruptible power supply The computers can be equipped with an optional uninterruptible power supply (UPS). Example of UPS In addition, the entire system can be connected to the hospital's emergency power supply. Forced shutdown and timer dialog The EMERGENCY OFF button interrupts the power supply to the system. Please be aware that a forced shutdown may cause data loss or data inconsistency in open workflows at any connected client. While scanning, you can stop the scanning and movement by pressing the STOP key. Always observe the patient directly. Press the nearest STOP key in the event of danger. You are informed that the system will shut down and a timer dialog is Force System Shutdown displayed after you press one of the STOP keys. You can cancel shutdown by pressing one of the STOP keys a second time or System will shut down in 55 seconds. Click Yes to force system shutdown or click No to clicking No. cancel system shutdown. Yes No Timer dialog *: only for SOMATOM go.Top, SOMATOM go.All, SOMATOM go.Up, SOMATOM go.Now, System start up To switch on the system again, press one of the following buttons: . The On/Off switch in the smart connector board / gantry connector box SOMATOM X.ceed, SOMATOM X.cite and NAEOTOM Alpha SOMATOM go .* Switch ON . The wall switch ON button if installed Wall switch Example cases of two start ups The system will need to start up twice for it to operate normally after the main power has been restored in the following two scenarios: 1. The system has an LCB but no uninterruptible power supply (UPS) or an exhausted UPS, and the input power of the LCB is disconnected. Example of the UPS 2. The system has an LCB and a UPS, and after the input power of the LCB is disconnected, the emergency power off button is pressed. System checkup To ensure the safe operation of the system, a checkup procedure should be carried out to correct any irregularities and to ensure the detector is at the correct operating temperature. Examination System Check Lock This checkup procedure should be carried out before any patient examination every time there is a forced shutdown, or a STOP key has been pressed. In addition, please make sure that the gantry and table move safely and correctly. Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Siemens Healthcare GmbH 2022 Healthineers
- ct stop
- shut down