Correcting Radioisotope Dose and View Names Symbia Pro.specta™ systems VA10 and above Correcting Radioisotope Dose 1. Navigate to the Patient Browser and locate the series to be corrected. NOTE: Series and patient data may not be corrected if the patient still has an open Examination. 2. Either Right-click on the series and select Correct -OR- single-click on the series and select the Correct icon in the Patient Browser. Series ICOM Import Export Correct Delete Manage Raw Data Correct Data Static RT ANT O Open POST RT Imm View as Read-Only Open with View as Read-Only with Set Delete Protection state Set Archive state Correct Cut & Paste Delete Del nstances Manage Raw Data 3. Select the Instance level tab in the newly opened Correction window. Correction of Series PATIENT, NAME (01/22/1969) Patient Study Series Instance (2) Unrestricted | Published by Siemens Healthineers AG, 2024 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 2/8/2024 | QR700005257 Healthineers 4. Type in the administered dose in either MBq or mCi. Contrast Agent Contrast Total Dose ¢ ml Patient Orientation Calibration Image Yes No 44.40 MBq Radionuclide Total Dose 1.2 - mCi Detector 1 View Name Detector 2 View Name 5. Click OK Correcting View Names for Static, Dynamic, or Wholebody series 1. Single-click and select the series in the Patient Browser that needs to be corrected. 2. At the Instance level, right-click on the image to be corrected. For dual-head images, Instance 1 will be the detector one image, and Instance 2 will be the detector two image. Instances O Open View as Read-Only @ Open with View as Read-Only with Set Archive state Correct Split to New Series Unrestricted | Published by Siemens Healthineers AG, 2024 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 2/8/2024 | QR700005257 Healthineers Page 2 of 4 3. Type in the desired view name under Detector 1 View Name. NOTE: Even if cor- recting detector 2 image name, the text will still go into the Detector 1 View Name field. Contrast Agent Contrast Total Dose ml Patient Orientation Calibration Image Yes No 0.00 MBq Radio Radionuclide Total Dose 0.00 mCi Detector 1 View Name LT POST RT . Detector 2 View Name 4. Click OK. Unrestricted | Published by Siemens Healthineers AG, 2024 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 2/8/2024 | QR700005257 Healthineers Page 3 of 4 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthineers AG 2024 Siemens Healthineers Headquarters Local Contact Information Legal Manufacturer Siemens Healthineers AG Siemens Medical Solutions USA, Inc. Siemens Medical Solutions USA, Inc. Siemensstraße 3 40 Liberty Blvd. Molecular Imaging 91301 Forcheim, Germany Malvern, PA 19355-9998 USA 2501 N. Barrington Road Phone: +49 9191 18-0 Telephone: +1-888-826-9702 Hoffman Estates, IL 60192 USA siemens-healthineers.com Customer Care Telephone: Telephone: +1 847 304-7700 +1-800-888-7436 siemens-healthineers.com/molecular-imaging Unrestricted | Published by Siemens Healthineers AG, 2024 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 2/8/2024 | QR700005257 Healthineers Page 4 of 4

  • dose
  • view name