Dual Volume viewing - control room (VExx)
This job aid will describe the workflow for creating a dual volume on VExx application software.
Dual Volume Viewing - Control Room (VExx) job aid Angiography – ARTIS software VExx An additional job aid is available on PEPconnect to determine the software version of the system. Dual Volumes are used to display and manipulate Mask and Sub images separately. For example, this allows bones, clips, or coils to be shown in a different color from the vessels. To visualize im- ages as a Dual Volume, a DSA or DSA DCT spin is required. A DR or DCT spin cannot be used, as they only reconstruct a single volume. Prerequisite: All three types of reconstructions are required to be in the Local Database – Sub, Nat Fill, and Nat Mask. If all three are NOT in the Local Database, this will not work. Users could create secondary reconstructions of the missing reconstructions. 3 3D Head Sub Medium EE Auto Mo [AX3D] XA 3 3D Head Nat Fill Medium HU Auto [AX3D] XA 3 3D Head Nat Mask Medium HU Auto [AX ... XA Examples of a Dual Volume Unrestricted 0 Published by Siemens Healthineers AG © Siemens Healthineers AG, 2025 SIEMENS Master Template Effective Date: 3/5/2025 | HOOD05162003074494 Job Aid Effective Date: 02/26/2025 | QR700019670 Healthineers 1. Perform any DSA or DSA DCT spin protocol. 2. Images will automatically transfer to the 3D Sharing in the control room. a) Previously performed DSA or DSA DCTs can also be loaded into the Viewing Segment. 3. Click on the Show Layouts icon. Viewing Review and Proc ... Review volumes loaded from the patient browser 4. Select the DSA layout under the Multiple Volume Viewing section. Multiple Volume Viewing DSA 5. Once the layout has loaded: a) Nat Mask and Sub reconstructions will automatically load in the VRT segment. b) Nat Fill images will automatically load into the three MPR segments. 39 38 AM 5/26/2029 SL 0.5 MF The MIP Thin 20.05-26-06:38:00-STD LAO 90 / 0 20.05 26-00:39:00-STD- TDC Cary 3D Body Mat Fil Ful HD .. AXIOM-Ards 20.05.26-06:38:00-STD VE 108 200118 20.05.26-06:39:00-STD -.. 3D Body Sub Ful EE Au .. ' 1/1/1900 HFS *1/1/1900 XA XA 5/26/2020 7:39:59 AM 5/26/2020 7:39:59 AM 3D Body Nat Mask Ful .. 3D DSA Fused> 1395| ¢ Ha 0/0 Unrestricted 0 Published by Siemens Healthineers AG © Siemens Healthineers AG, 2025 SIEMENS Master Template Effective Date: 3/5/2025 | HOOD05162003074494 Job Aid Effective Date: 02/26/2025 | QR700019670 Healthineers Page 2 of 5 6. Dual Volume properties will be displayed docked under Viewing. a) Click on 1 or 2 to view the volumes independently. i. The bar will display at the top of the 3D. Dual Volume Define settings for the Dual Volume visualization ... K X 2 b) You may also undock the Dual Volume to better visualize which reconstruction is selected. Dual Volume ? @X Adjust visualization of fused volumes. The blending method is predefined by volume types and configuration. Visualization Volumes 1: 3D Head Sub Medium EE Auto Mo [AX3D] 10/11/2024 1:3 ... 2: 3D Head Nat Mask Medium HU Auto [AX3D] 10/11/2024 1 .... Fusion Method Addition (1 + 2) Swap order Close c) If the Dual Volume Properties box gets closed or does not display, select Volumes from the Segment Menu, and select Dual Volume Properties... icon. i. Both volumes need to be loaded, and the VRT segment needs to be selected for Dual Volume Properties to be available in the Volumes menu. Segment Menu ? GX Volume Volume Opacity (%) Images (MPR) 100 Measurement 4D Segmentation Orientation 180 A (anterior-posteri .. Storing X-Ray Unrestricted 0 Published by Siemens Healthineers AG © Siemens Healthineers AG, 2025 SIEMENS Master Template Effective Date: 3/5/2025 | HOOD05162003074494 Job Aid Effective Date: 02/26/2025 | QR700019670 Healthineers Page 3 of 5 7. Using the middle mouse button, the user can window the segments to visualize the volumes better. a) If only one volume is displayed, this can be done on the individual volumes; if loaded together, the position of the mouse will determine which volume is windowed. b) Windowing in the left half of the image segment affects Volume 1 only while win- dowing in the right half of the image affects Volume 2 only. 8. You may select a different visualization Preset. a) Click on the Preset Gallery icon. i. Found in the Segment Menu under Volume or on Favorite’s bar. Segment Menu ? BX Volume Volume Opacity (%) 100 Images (MPR) Measurement 4D Segmentation Orientation 90 180 A (anterior-posteri ... Storing X-Ray b) Select the VRT segment, choose the Type filter needed, and left click on the desired preset. i. Each fused volume has its own set of visualization settings. If only Volume 1 is selected, any change in visualization settings will only affect Volume 1. The same holds true if only Volume 2 is selected. ii. Additionally, the VRT segment and MPR segments are treated independently. An MPR segment must be selected to apply a different visualization preset. Preset Gallery |3D Sharing ? X Type Abdomen Abdominal ColonTransp ... Dyna3DBody DynaCTBody Embolization .. EVAR V Shading Less Unrestricted 0 Published by Siemens Healthineers AG © Siemens Healthineers AG, 2025 SIEMENS Master Template Effective Date: 3/5/2025 | HOOD05162003074494 Job Aid Effective Date: 02/26/2025 | QR700019670 Healthineers Page 4 of 5 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthineers AG 2025 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com Unrestricted 0 Published by Siemens Healthineers AG © Siemens Healthineers AG, 2025 SIEMENS Master Template Effective Date: 3/5/2025 | HOOD05162003074494 Job Aid Effective Date: 02/26/2025 | QR700019670 Healthineers Page 5 of 5
- angio reconstruction