DryCool technology
This job aid gives an introduction to the Magnet DryCool technology and explains how it works.
Target group: All users.
Recommended to be viewed on the following devices: All (incl. tablet, smartphone).
SIEMENS Healthineers MAGNETOM Systems with DryCool technology Template Effective Date: 10 Aug 2021 | HILS 2223 Job Aid Effective Date: 02 Sep 2024 | QR700012313 Unrestricted I Published by Siemens Healthineers AG I © Siemens Healthineers, 2024 Magnet DryCool technology - SIEMENS Healthineers Table of contents Introduction to Magnet DryCool technology 3 What is Siemens Healthineers DryCool technology? 4 How does DryCool technology work? 5 Self-monitoring and self-protection activation scenarios 6 DryCool technology – Summary 14 UX AuntMinnie Europe. DESIGN reddot winner 2021 AWARDS WINNER: Best New Radiology Device 2021 2 Job Aid Effective Date: 02 Sep 2024 | QR700012313 Unrestricted I Published by Siemens Healthineers AG I © Siemens Healthineers, 2024 DryCool technology SIEMENS Healthineers Freedom beyond helium 0.71 2 He liquid helium Powered by automated intelligence No quench pipe SIEMENS Healthineers Sealed-for-life* magnet design: • Filled with helium gas Self-monitoring & protection: MAGNETOM Free Max before shipping • No need for liquid helium reload • Prevent damage to the SIEMENS Heolthingers system hardware • Preserve image quality AutoResponse except in safety related interruptions Compact design: Easy siting 3 * Under normal operating conditions Job Aid Effective Date: 02 Sep 2024 | QR700012313 Unrestricted I Published by Siemens Healthineers AG I © Siemens Healthineers, 2024 What is Siemens Healthineers DryCool technology? SIEMENS Healthineers The DryCool magnet features a revolutionary conduction-based technology that enables it to maintain the operating temperature at the DryCool Technology optimal level with just a small amount of 0.7 l liquid helium. Sealed for life: Helium is intended to remain within the system under normal operating conditions for the entire lifespan of the equipment. The design includes a reservoir to store helium gas in unstable temperature events, eliminating the need for a quench pipe. Resilient system: Even in cases of an unstable event (caused by a blackout, for example), DryCool technology is coupled with intelligent automation that enables the system to react to the conditions and maximize clinical uptime. 4 Job Aid Effective Date: 02 Sep 2024 | QR700012313 Unrestricted I Published by Siemens Healthineers AG I © Siemens Healthineers, 2024 How does DryCool technology work? SIEMENS Healthineers 0.71 He liquid helium O Powered by automated CK intelligence Intelligent automation adapts to unfavorable temperature & SIEMENS Healthineers power conditions. Self-monitoring and protection to prevent KOTTTTT Potentially fully automated damage to the system MAGNETOM Free Max response to power/temperature hardware and preserve SIEMENS Neoifsingers irregularities without human image quality. interaction. 5 Job Aid Effective Date: 02 Sep 2024 | QR700012313 Unrestricted I Published by Siemens Healthineers AG I © Siemens Healthineers, 2024 AutoResponse SIEMENS Healthineers Self-monitoring and self-protection activation scenarios Coldhead temperature [K] Power outage System ready for or cooling measurement interruption System not again occurs Scan is ready for Interruption is stopped measurement resolved System time t0 t0+10min t0+30min t0 + N min t0+~2xN+x min running 6 Job Aid Effective Date: 02 Sep 2024 | QR700012313 Unrestricted I Published by Siemens Healthineers AG I © Siemens Healthineers, 2024 AutoResponse SIEMENS Healthineers Self-monitoring and self-protection activation scenarios Coldhead temperature [K] The system continuously controls and monitors the status of the components and their performance (for example, the temperature). time System running 7 Job Aid Effective Date: 02 Sep 2024 | QR700012313 Unrestricted I Published by Siemens Healthineers AG I © Siemens Healthineers, 2024 AutoResponse SIEMENS Healthineers Self-monitoring and self-protection activation scenarios Coldhead temperature [K] Power outage: Cooling interruption: The magnet remains in the field, but the After the error message pop-up, the system remains in field, and you can continue to whole system (including console) switches scan for another 10 minutes. off immediately. Both events impact on the system’s temperature: • The gradient coil’s temperature starts increasing. With time, this can result in compromised diagnostic image quality. • The magnet’s temperature increases, and helium warms up quickly. With time, it begins to convert from liquid state into gaseous state. MR scanner AF X X Magnet Supervision: Magnet Failure detected. Please contact Siemens Healthineers service. Cooling System: Temperature in the Power outage secondary water circuit too high. X or cooling Please contact Siemens Service. interruption occurs OK 33.5°K System time t0 running 8 Job Aid Effective Date: 02 Sep 2024 | QR700012313 Unrestricted I Published by Siemens Healthineers AG I © Siemens Healthineers, 2024 AutoResponse SIEMENS Healthineers Self-monitoring and self-protection activation scenarios Coldhead temperature [K] Power outage: Cooling interruption: The magnet remains in field 10 minutes after the interruption, the gradient’s coil and the system is still off. temperature has increased enough to compromise the image quality. Therefore, any ongoing scanning activity is automatically terminated. O Magnet Supervision: Scanning will be stopped in 10 minutes if scanning continues. Scan is Please contact Siemens Healthineers service. ≥35°K stopped ~ Power outage or cooling interruption occurs System time t0 t0+10min running 9 Job Aid Effective Date: 02 Sep 2024 | QR700012313 Unrestricted I Published by Siemens Healthineers AG I © Siemens Healthineers, 2024 AutoResponse SIEMENS Healthineers Self-monitoring and self-protection activation scenarios Coldhead System not temperature [K] ready for 40°K measurement If the interruption is not resolved within 30 minutes, the system temperature would be too elevated: Once the system`s self-protection is activated, the system initiates an automatic self ramp-down of the magnet, which can not be deactivated. Power outage: Cooling interruption: System is still off. System workplace is still active, and MR Scan is MR View&GO is not available. View&GO can be used. Please note: You cannot scan. stopped MR scanner AF X Power outage Magnet Supervision: Magnet error. Magnet or cooling s not ready for scanning. X interruption OK occurs System time t0 t0+10min t0+30min running 10 Job Aid Effective Date: 02 Sep 2024 | QR700012313 Unrestricted I Published by Siemens Healthineers AG I © Siemens Healthineers, 2024 AutoResponse SIEMENS Healthineers Self-monitoring and self-protection activation scenarios Interruption is resolved Power outage: Cooling interruption: Coldhead System not temperature [K] ready for The power has Cooling is restored, and system been restored workplace is still active, but system measurement and the cooling of cannot scan. MR View&GO can still be the magnet has used. started again. The magnet is not yet back in field. The self-protection remains active after interruption. The system works in the The workplace background to restore adequate can be turned on measurement conditions to ensure Scan is again, but the diagnostic quality. stopped system is not yet ready to scan. Please note: During this time, the system messages provide information Power outage (countdown) about when the system will or cooling be ready for scanning again. If no countdown is shown, please call interruption Siemens Healthineers Service. occurs System not ready for measurement. Magnet will be ready in approx. 139 minutes. time System t0 t0+10min t0+30min t0 + N min * running 11 * The time for resolution of the interruption (t0 + N min, in the time axis) is variable case by case. Job Aid Effective Date: 02 Sep 2024 | QR700012313 For example, the time to resolution depends on the type of interruption encountered, response times, etc. Unrestricted I Published by Siemens Healthineers AG I © Siemens Healthineers, 2024 AutoResponse SIEMENS Healthineers Self-monitoring and self-protection activation scenarios Interruption is resolved Coldhead System not temperature [K] ready for measurement Self-protection mode is deactivated after ~2xN min and then the magnet can ramp-up again.* Afterwards, reboot the scanner before starting normal operation (e.g., scanning) again. Scan is stopped Power outage System ready for or cooling measurement interruption again occurs 33.5°K System time t0 t0+10min t0+30min t0 + N min t0+~2xN+x min running 12 Job Aid Effective Date: 02 Sep 2024 | QR700012313 * Please refer to your data sheet for the specific periods until the system is ready for measurement. Unrestricted I Published by Siemens Healthineers AG I © Siemens Healthineers, 2024 AutoResponse SIEMENS Healthineers Self-monitoring and self-protection activation scenarios Self-monitoring active Self-protection active Power outage System ready for or cooling measurement interruption System not again ready for occurs Scan is Interruption is stopped measurement resolved time System t0 t0+10min t0+30min t0 + N min t0+~2xN+x min running 13 Job Aid Effective Date: 02 Sep 2024 | QR700012313 Unrestricted I Published by Siemens Healthineers AG I © Siemens Healthineers, 2024 DryCool technology – Summary SIEMENS Healthineers Timings and information about the self-protection mode • The self-protection mode normally activates 30 minutes after an issue. Once automatically activated, the self-protection mode cannot be manually deactivated. It will automatically deactivate when adequate measurement conditions are restored. • The countdown timer is automatically provided in the system messages. System not ready for measurement. X The estimate is provided in real time due self-monitoring and depends on the Magnet will be ready in approx. 139 minutes. system conditions (type of issue, resolution time, gradient coil temperatures, etc.). • The time to readiness is the time needed for the system to return to normal operational state. This, however, may vary depending on the system and situation. Please refer to your data sheet for the specific information. • Throughout the period in which the system is not ready for scanning, you are not allowed to have patients in the scanner room, and you shall not interfere by trying to scan patients or phantoms. Please also continue to follow all the normal MR safety measures. 14 Job Aid Effective Date: 02 Sep 2024 | QR700012313 Unrestricted I Published by Siemens Healthineers AG I © Siemens Healthineers, 2024 SIEMENS Healthineers Please note this learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Siemens Healthineers HQ I Siemens Healthineers AG Siemensstr. 3 91301 Forchheim Germany Phone: +49 9191 18-0 15 siemens-healthineers.com Job Aid Effective Date: 02 Sep 2024 | QR700012313 Unrestricted I Published by Siemens Healthineers AG I © Siemens Healthineers, 2024
- dry cool
- cool
- dry
- technolog
- sustainable
- cooling
- helium
- DryCool technology