Data Assignment - Visual mode (USA)
This video introduces you to Data Assignment, which is one of the components within the Layout Editor. It allows you to define the rules determining the images that are displayed in the image segments.
Target group: All users
Audio: Yes
Recommended to be viewed on the following devices: Laptop, desktop computer (sufficiently large display required)
Data assignment is one of the components within the layout editor. This tool allows you to define the rules determining the images that are displayed in the image segments. Please keep in mind that the user interface may differ slightly on different host systems. Consider the following scenario for a magnetic resonance brain examination you. Want to create a two by two layout? In the first row you want to visualize a native acquisition and the corresponding post contrast or the dark fluid images if no post contrast is available. In the 2nd row, you want to visualize the exponential ADC images in the corresponding ADC maps. You open the layout. Editor tool and create a two by two layout. Start the Data assignment tool to define the content of the image segments. The data assignment interface shows up in all image segments. The rules that establish the content of the image segments are defined via the time point, the modality, and the series description of the base series. From the drop down menu, select the desired time point and modality to. Define the series description for the desired content. You can use different. Logical operators. The system applies these operators to the defined strings and searches for the series description that matches the resulting condition, check the corresponding series in the patient browser and complete the definitions of the different image segments. In this example you must define a series description that contains M pure age and native as you don't want any of the MPR images. You should add that the. Series description must not contain MPR. Please note that the definition of the series description is not case sensitive. To define the content of the top right segment, you can copy and paste the previous definition and change the condition native with KM. If the defined post contrast images were not acquired or were not found, the dark fluid acquisition should be displayed. To configure it, we add an additional definition, in this case the. Series description should. Contain dark fluid. Please note that the priority of the search is from left to right to. Change the priority of the defined rules. Drag and drop the corresponding definition tab to the desired position. In this case you want to have the post contrast images if acquired, therefore the. Definition tab is at the farthest left position to. Define the content of the bottom left segment. You can use ends with_EXP for the last image segment. You can copy the definition of the previous one and update_EXP with_ADC deactivate. The data assignment tool and check that the configuration is correct. Repeat the same check with the alternative definitions. For this, change the order of the definition tabs in the corresponding image segments. Don't forget to set the correct order back again. For easy reading, you can synchronize the content of the image segments. You can now save. Your layout. Your layout is now available in the layout gallery.
3/20/2019 31 26 25 24 18 17 16 15 13 5.0 539 3.0 50 499 20 356 17/150 019 14 1/1/1967 10 12 11 142 /20/2019 443 334 187 716 Data Assignment Visual mode This training material is based on the medical device syngo.via basic VB60E. SIEMENS . Vida Head Healthineers * 1/1/1967 M Austria MAC ... Viewing Definition 1 X Series MR general Base Series Add Timepoint Study Modality Series Name Series Description contains 7:02 AM Favorite Tools t1_vibe_fs_cor_KM Visual Expert t1_mprage_tra_nativ_MPR_SAG Create Overlay Series t1_mprage_tra_KM with Segments with Segments Findings Printing 2:35 PM None Lines MR XA11 HFS STUDY ID 3aaaa1348 SL Zoom 1.88 Prohance 18 00ml 10 IMA 1 FRM 1/30 SPC TE 86.2 SP H85.6 t1 mprage tra KM SP H108.6 MAGNETOM Vida 9 IMA 1 FRM 1/30 TA 03:33 BW 574.0 AHL W 1719 syngo.via Scanner Al-Rad Companion Syngo Carbon View&GO Space Please keep in mind that the user interface may differ slightly from what is shown in this video. The actual usage of the tool may differ slightly on the different host systems, for example, on syngo.via, Syngo Carbon Space, syngo.via View&GO, Al-Rad Companion or on the scanner. However, the intended purpose of the tool is the same. The tool functionality defined in this video is applicable to any of the Siemens Healthineers products in which you find this tool. HAL MAONETOM Vida FXA11 6 IMA 1 FRM 1/40 SP H89.1 SP P111.4 TA 01:07*3 BW 223.0 LPH RAF TA 01:42*2 t1_mprage_tra_nativ 2D 2:34 PM TP FoV 223*230 12_2d_cor_#6 Vida_Head Zoom 1.50 7 IMA1 FRM 82/82 Native Postcontrast Dark Fluid Exp ADC ADC Layout Gallery Public Layouts W 1 Siemens Layouts Layout operations MPR 3TP 4TP ET CT Spine Favorite Scroll Rotate Synch OpenAp .. Line Ranges Zoom 0.54 W 1069 8 IMA 1 FRM 1/30 IC1 BW 289.0 Please drag data from Series Navigator. Data Hide Export Point 3D R Series Description Prior 02 Current Series Description ANY DX Grou ... MG MR contains either of ends with Series Descriptiol contains not contains Patient Browser Read (1) More Filters Results (1 results, 2:35:23 PM) Study ID Date of Birth Study Date a ... Study Descrip ... Series Date a ... 3aaaa1348 Austria_MAC ... 3/20/2019 7 :... Pathology P ... t2_tse_dark-fluid_tra Diffusion_Resolve_SMS_BT#12_TRACEW Diffusion_Resolve_SMS_BT#12_EXP Mag_Images Pha_Images epi_perf Instances 8,500.00 ms Search successfully completed Patient Name MM Reading Patient ID Layout Editor fs_cor_KM ge_tra_KM_MPR_SAG ages(SW) Definition 1 Ser ... mprage Expert starts with mpr Visual t2 2d cor #6 dark-fluid mprag urrent Series Description ends with VA 2:37 PM Austria_MAC_3aaaa1348 TE 3.3 Ref .: DemoCongress TA03:33 latest Definition 2 X al Expert Base S moCongress 3D Ref. TE 87.0 TA01:42*2 6 IMA1 FRM 1/40 Definition 2 farts Data Assignment RXA11 TA03:52 ongress R XA11 atest #XA11 Zoom 0.94 10 IMA1 FRM 1/30 Synchronizations Display Type LUT Slice Thickness Navigation +LPH Windowing OK 15 IMA 1 FRM 24/192 24 IMA 1 FRM 24/192 W 716 Prohance 18.00m TR 1890.0 ₩ 443 HF Save As Layout name: Cance ALL MRB MRBrain_ba Stack 2x2 MPR MIP Split Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Unrestricted | Published by Siemens Healthineers AG | Siemens Healthineers AG, 2024 Siemens Healthineers HQ | Siemens Healthineers AG Siemensstr. 3 91301 Forchheim Germany Phone: +49 9191 18-0 siemens-healthineers.com SIEMENS
- data assignment
- layout editor
- image segments