Daily system checks & troubleshooting (VExx)

This job aid will review daily system checks on systems with VExx software. 

Daily System Checks & Troubleshooting (VExx) job aid Angiography – ARTIS software VExx An additional job aid is available on PEPconnect to determine the software version of the system. Daily system checks should be performed before the start of cases. Start of day 1. Turn System On (1) a) Make sure the on-site main switch is switched on. (2)- (3) 2. Unplug the wireless foot pedal. 3. Test Fluoro and Acquisition. 4. The imaging system continuously informs you about its status. Check system messages on the message bar on the Exam Room/Control room monitors. a) If any message has SC on the message bar, contact the Siemens Service Center i. 1-800-888-7436, and follow the prompt to Technical Support, provide your Func- tional Location Number. 5. Perform safety checks before each examination and check that all displays and signal lamps are functioning properly. • Confirm all emergency stops are not pushed in. • System movements • Collision sensors • Radiation indicators • Image orientation, image rotation, collimation Unrestricted 0 Published by Siemens Healthineers AG © Siemens Healthineers AG, 2025 SIEMENS Master Template Effective Date: 3/5/2025 | HOOD05162003074494 Job Aid Effective Date: 03/05/2025 | QR700019668 Healthineers • FD input format/zoom factor. 6. Activate Stream to display Siemens Live and Reference image on the 3rd party monitor as applicable. 7. Confirm that the Block Movement and Radiation buttons are inactive. 8. View and configure the Siemens large screen display, if applicable. End of day 1. Shut the System down. a) Home > Power Button > Shut Down System DOD Examination System Messages Lock G b) Shut down should be performed every 24 hours. 2. Plug the Wireless Foot pedal in. a) Footswitch has a range of approx. 5 m (16 ft). b) Footswitch can be used during the procedure while plugged into a power source if needed. Unrestricted 0 Published by Siemens Healthineers AG © Siemens Healthineers AG, 2025 SIEMENS Master Template Effective Date: 3/5/2025 | HOOD05162003074494 Job Aid Effective Date: 03/05/2025 | QR700019668 Healthineers Page 2 of 4 Collision Override Press the ? key on the PCM and deflect the corresponding joystick simultaneously to perform an override. The message "Collision control deactivated" appears. Soft Reboot Simultaneously, press the ? key and the emergency STOP button on the Pilot control module. The computer will restart and should be ready for operation shortly. Once completed, pull the emergency STOP button out. ? STOP Emergency Shutdown button (EPO) The emergency SHUTDOWN button is used to immediately switch off the electric power of the entire system in an emergency. This shutdown is like a power failure, an uncontrolled process. Therefore, use this button only in an extreme emergency, such as a fire. Using the emergency SHUTDOWN button (installed on-site) means that: • All unit movements will be interrupted. • Radiation will be turned off. • The current system program will be interrupted. • Current operating sequences will be interrupted and cleared. • All current acquisition data will be cleared unless saved to non-volatile memory. • Data like unsaved images, exporting, filming, jobs, etc., could be lost. • The tube cooling system is also disconnected from the power supply, and the tube can overheat. • If a flat detector is used, it is also disconnected from the power supply. After the power has been switched on again, an additional waiting time is required to ensure optimum image quality. Unrestricted 0 Published by Siemens Healthineers AG © Siemens Healthineers AG, 2025 SIEMENS Master Template Effective Date: 3/5/2025 | HOOD05162003074494 Job Aid Effective Date: 03/05/2025 | QR700019668 Healthineers Page 3 of 4 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Op- erator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthineers AG 2025 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com Unrestricted 0 Published by Siemens Healthineers AG © Siemens Healthineers AG, 2025 SIEMENS Master Template Effective Date: 3/5/2025 | HOOD05162003074494 Job Aid Effective Date: 03/05/2025 | QR700019668 Healthineers Page 4 of 4

  • daily start
  • qa
  • troubleshoot