Siemens Healthineers Academy

Daily Quality Control on the Symbia Pro.specta™ Video

This video provides an overview of the daily QC for the Symbia Pro.specta system.

Note: Video does not contain spoken dialogue.

30 1111 1000 1040 1084 1053 1057 10 1200 1035 1140 1036 1096 1101 17:54 17:53 17:52 17:51 100 17:50 17:49 17:48 17:47 17:46 17:45 17:44 17:43 17:42 Siemens Healthineers presents Daily Quality Control SIEMENS meduser Examination System Check Lock Click System Check to enter the NM Daily Floods page. 3:17 AM Starting Application ... meduser ? EN NM Daily Floods NM Monthly QC Suite Checkup Daily QA Overdue Example Workflow Close Confirm GO Cancel ESim / meduser Free (Restricted Remote Access) Intrinsic Verification - AQC Protocol AQC Sources Co-57 Tasks Detectors MCounts Date and Time Status Tuning Both N/A To Do Peaking Verification 01/13/2021 2:53 AM OK End by Wednesday 5:00 AM Click Start (Caution! System motion will occur and a radiation source will be exposed) Start Spectrum Check the sbox next to the tasks you want to run and click Start. End by As soon as possible End by As soon as possible Click Start (Cautionl System motion will occur and a radiation source will be exposed) Pending Motion In Progress With Automatic Collimator Change, the system will begin removing the collimators. Once the collimators have been removed, the system will get in position to start Tuning. CAUTION DO NOT IMPACT THIS SURFACE AS T IMPACT THIS SURFACE AS LE CRYSTAL DAMAGE MAY OCCUR SURFACE AS CUR CA IRREPARABLE CRYST IRREPARABLE CRYSTAL DAMAGE MA IRREPARABLE CRYSTAL DAMAGE MAY OCCUR The point source will automatically extend from the patient bed. Running End by As soon as possible v 3:18 AM From the console, you can see the Tuning task is running. Results Tuning Range Zmap HVDAC Normal Extended Iteration 1 Tuning will be completed for both detectors. Finished 4 01/26/2021 3:19 AM Once Tuning is complete, the Verification will begin. Radiation source is extending Time Remaining 19565 kCnts Co57 Siemens 100 % Posterior Projection 4:01 AM 19572.2 kCnts 19593.1 kCnts 19609.1 kCnts 19617 kCnts 19609.9 kCnts 100 N 19631.5 kC 19639.3 kCnts The growing image will appear on the right side of the screen. 19670.3 kCnts 19672.2 kCnts For the CT Quality Check, attach the phantom holder to the end of the patient table. Mount the phantom on the phantom holder and tighten the clasp. nolder and tighten the clasp. Index the bed into CT Brain position using the hand controller. SYMBIA Pro.specta The rear bed will retract to make room for the phantom. The rear bed will retract to make ro Align the phantom in the gantry to run the Quality test. Align the phantom in the gantry to After completing the Quality test, retract the patient table. Carefully remove the phantom. Remove the bracket by pressing the button under the patient table. Home the gantry and the system will be ready for the day. Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. C Siemens Healthcare GmbH 2022 Healthineers

  • qc
  • denali
  • simba
  • symba
  • simbia
  • smb
  • sb