CT Safety Training - System Checkup and Daily QA Video
This CT safety training video introduces you to how to perform the system checkup and daily QA on your CT system.
CT safety training. System checkup and daily QA. To ensure image quality is stable even under variable environmental conditions, it is important you perform a system checkup once you start the system and then run a daily quality assurance approximately one hour later. The system checkup will only take approximately 5 to 6 minutes and is required regardless of whether the CT scanner was used continuously or intermittently. This calibration is important when the gantry has been powered off, for example overnight or between working shifts. The Daily quality test is automated. You can perform the whole test according to the guidance on the screen. Before you start the quality measurement, you must perform the calibration and position the Phantom set. To access the daily quality function on the access bar, click the settings icon and from the menu choose daily QA. Alternatively, on the home screen, click system check and from the Navigation Pane on the left of the system check window, select Daily QA. Instructions on the daily quality test are then displayed. For the daily QA or the system check you need to mount the Phantom set at the head end of the patient table with the Phantom holder. The video here will show you how this is done. After you have properly attached the Phantom. Please set the gantry tilt to zero degrees. Then using the remote scan control, move the table until the laser light markers are set for the reference marking point that is on the slice thickness portion of the Phantom. The daily quality measurements only require checking of three parameters on the water Phantom. The CT value of water and the homogeneity of the images are calculated in Hounsfield units. The pixel noise of the images is calculated as a standard deviation. And tube voltages are measured directly at the X ray tube.
10/18/2021 500 100 SIEMENS Healthineers CT Safety Training System Checkup and Daily QA HOOD05162003242058 Unrestricted @ Siemens Healthineers, 2021 Examination System Check Restart Lock CH Systern Check Starting Application ... Scan Checkup Daily QA myNeedle Laser Check Close For optimum image quality and system safety, please run the Checkup procedure. Exit the scan room. The table will move automatically. X-rays will be produced during the Checkup procedure. Checkup has started. Press the GO button to continue. Repeat GO Cancel Workflow 'Checkup @ System Check' started. Function 'Unconfirmed FRU Replace Check @ Checkup @ System Check completed. Table Homing Patient table homing needs to be executed. Function System Config Check @ Checkup @System Check' started. Function 'System Config Check @ Checkup @ System Check' completed. Scan Recon Recon Function 'Focus Zero Position Check @ Checkup @ System Check completed. Press START 120 kV, 100 mA, 0.5 s, 2x64x0.6 mm (A) Function Focus Zero Position Check @ Checkup @ System Check' started. Gantry accelerating Daily quality assurance should be performed approximately one hour later the system checkup. Function Image Quality Evaluation @ Checkup @ System Check' started. Function 'Emitter Wear Down @ Checkup @System Check completed. Function 'Dose Check @ Checkup @ System Check completed. Function 'Pixel Quality Equalization @ Checkup @ System Check started. Function 'Pixel Quality Equalization @ Checkup @System Check' completed. Calibration is important when the gantry has been powered off. Function Safety System Self-Test@Checkup@System Check' started. 80 kV, 100 mA, 0.3 s, 64x0.6 mm (A) Daily QA has started. Position system phantom at the gantry center. The Inner lightmarker must hit the reference position of the phantom. Click GO when ready. Daily Quality Test The inner lightmarker must hit the reference position of the phantom. Administration Portal Administration Portal [EN] Clinical Configuration Resume syngo Remote Assist Screen recorder Savelog Remote Service Exam Designer Create Screenshot Fast Contact File Browser Load Service Pack Direct Laser Check What is New Configuration Panel Resuming was successful SOMATOM SOM Function 'Workfl ow Preparation @ Daily QA @ System Check' completed. Function 'Phantom Position Check @ Daily QA @ System Check started. X-rays will be produced during the Dally QA procedure. 120 kV, 180 mA, 1 5, 1x5 mm (A) Siemens Service ZMP Service 11330001_123043 syngo CT VA40A 101 IMA 1 10cm KV 120 mAs 180 OT 0.0 Function 'Phantom Position Check @ Daily QA@ System Check completed. Function 'Homogeneity/Water @ Daily QA@ System Check started. ZMPT Quality 11330001_123043 SOMATOM X.cite 102 IMA7 5cm Eff. mAs 191 EN 100 kV, 191 mA, 1 s, 2x5 mm (64x0.6 mm) (A) 2:58:15.73 PM Function 'Homogeneity/Water @ Daily QA @ System Check' completed. Function 'Noise @ Daily QA @ System Check' started. Siemens Quality HFS 2:58:50.10 PM 115 IMA7 KV 100 100 kV, 191 mA, 1 5, 2x5 mm (64x0.6 mm) (A) 2:58:55.97 PM 114 IMA 4 Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. C Siemens Healthcare GmbH 2021 Hea
- computed
- tomography
- ct
- safety
- system
- checkup
- qa
- quality