This CT safety training video introduces you to how to manage data correctly.

City safety training. Managing data. Topics to be covered in this video include. Safety information during shutdown. User access. Update of patient data. Local updates of patient data. Raw data deletion. And automatically generated reconstructions. Safety information during shutdown. A forced shutdown will stop all running applications and may lead to data loss or inconsistency in the open workflows at any connected client. To avoid this. Ensure before forced shutdown if possible, that there are no unsaved findings. All open workflows and running applications are closed. And inform other users at secondary workplaces to also close all open workflows. User access prevented due to forgotten or unknown accounts might leave system inaccessible. To avoid this, define a general user account for emergency access and assign it to a group and a role, both called emergency access. Define a local user account for emergencies. Password for this account should not expire. Do not allow users to change the password for the emergency account. Observe the following safety information when updating the patient data after the examination and reconstruction of images. Do not modify patient data after results have been calculated or performed. Correct and rearrange actions. While time critical cases are in progress. Always check the workflow section in the job view for time critical workflows. Updates to patient information done locally in organizer are not communicated to central information systems like risk or his. If the information being updated has to be centrally available across modalities, consider updating this information in the wrist. Before deleting raw data, make sure that all potentially necessary reconstructions are available for final diagnosis. Automatically generated reconstructions need to be always reviewed by a physician or technician before diagnosis. Additionally, archived original images must have sufficient quality for a review of result images on other DICOM nodes. If data is reviewed on a remote system, make sure it is verified in a timely manner.

601 10 12345678 10/01/1954 36 10/04/1965 12345679 *10/04/1965 10/4/65 56 47 61 11 20 14 10/04/2 42 12 13 SIEMENS . Healthineers CT Safety Training Managing Data HOOD05162003242058 Unrestricted Siemens Healthineers, 2021 Introduction to the Video Shutdown CT Safety Training - Managing Data Coming up in this video: . Safety Information during Shutdown · User access · Update of patient data · Local updates of patient data · Raw data deletion Automatically generated reconstructions A forced shutdown will stop all running applications and may lead to data loss or inconsistency in the open workflows at any connected client. To avoid this, ensure before forced shutdown if possible: . There are no unsaved findings . All open workflows and running applications are closed Inform other users at secondary workplaces to also close all open workflows User Accessmation During Shutdown User and Role Administration Users and Groups Associated with Roles User or Group BUILTIN\Administrators ClinicalAdministrator ITAdministrator Everyone Technologist Domain/host na |Windows User or Group (e.g ., dome Q Role User access prevented due to forgotten or unknown accounts might leave system inaccessible. User Access Role To avoid this: . Define a general user account for emergency access and assign it to a group and a role both called Emergency Access. Define a local user account for emergencies. Password for this account should not expire. . Do not allow users to change the password for the emergency account. Patient Browser Local Data demo X Q More Filters Print Open Open with DICOM Export Correct Recon Results (1 results, 3:37:10 PM) Series Patient Study Archived Corrected Series Number Series Description Modality # Instarices in ... Series Archived Exported Serie + Topogram 0.60 Tr20 cor CT CT Raw data 12345678 BUILTIN\Administrators Instances ate and Ti ... Study Descripti ... Abdomen Dos ... Update of Patient Data 3:37 PM Open Open with View as Read-Only with Batch Open Assign Workflow Search Patient with DICOM Q/R Add to Demo List Remove from Demo List Set Mark state Set Delete Protection state Set Archive state Remove Correction state New Examination ances Cut Paste Delete Del Manage Raw Data Series Number Series Description Correction of Patient Demo case (10/01/1954) Study Series (2) Instance (11) Title Last Name Demo case Edit First Name Other Patient Names Add Remove Suffix * Patient ID Issuer of Patient ID Other Patient IDs * Patient's Sex Ethnic Group Patient Comments Patient's Address OK Cancel Job View Patient Name Study Description Range Name Order Progress Short Term Storage Maintenance Abdomen DoseNotification(Adult) Abdomen Abdomen Br40 A3 Rib Data Publisher Media Network Abdomen 5.00 Br40 A3 Raw Data Abdomen 3.00 Br40 A3 sag Spine Message Prioritize CT Scan&GO Scan File Device Edit View Window Help Scheduler Emergency Register Procedure Patients (1 result(s), 1:12:00 PM) Q Search by Name, ID, DoB, Description, Procedure Date, Acc No. and Modality Exam Information Scheduled, Today Date and Time Today, Scheduled (1) John, Doe Requested Procedure Description *10/4/65, 12345679 10/04/2021, 15:45 15:45 10/4/21 Accession No ef713a4f-9657-4f Comments Emergency Patient Register Patient Patient Details Home GO Exam EN Local Update of Patient Data Loading details ... Save Last Name * John Doe Unit Year(s) Sex Height (ft) Height (in) Middle Name US Other Patient Ids Medical Information Admitting Diagnosis Alerts Medical Alerts Allergies Institution Institution Name Referring Physician Performing Physician Operator Pregnant Results (1 results, 3:44:23 PM) # Instances in ... Abdomen 5.00 Br40 A3 cor Abdomen 5.00 Br40 A3 ax Lung CAD [13] Candidates Raw Data Deletion 3:44 PM View as Read-Only Load Into myNeedle Guide Lo Delete Permanently Are you sure you want to permanently delete the selected data? All non-archived or non-protected data, as well as unsaved workfl ow or job results will be lost irrevocably. Yes No Automatically Generated Reconstructions SIEM Need to be always reviewed by a physician or technologist before diagnosis Additionally archived original images must have sufficient quality forta review of result images images on other DICOM nodes on other DICOM nodes If data is reviewed on a remote system, make sure it is verified in a timely manner Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. C Siemens Healthcare GmbH 2021 SIEMENS

  • computed
  • tomography
  • ct
  • safety
  • data
  • shutdown
  • patient
  • update
  • local
  • access
  • raw
  • automatic
  • reconstruction