Siemens Healthineers Academy

Create a Dot Engine/myExam Assist Program - USA

This job aid demonstrates you how to create a Dot Engine/myExam Assist program using the Program Editor in the myExam Cockpit.

Create a Dot Engine/myExam Assist Program Job Aid MR (Numaris XA50 Software) 1. To create a new Region Directory, select Organize Directories. 2. Select New Region Directory. 3. Type the name then select Enter. myExam Cockpit - Explorer myExam Cockpit - Explorer Explorer Pro Browse Explorer Import Export Pro Browse Import Export X × 1 Facilty New Region Directory Facilty New Region Directory Creates a new region Creates a new region New Program New Program [ Brain 4. Select the new Region. 5. Create a New Exam Directory by selecting Organize Directories. 6. Select New Exam Directory. 7. Type the name then select Enter. myExam Cockpit - Explorer myExam Cockpit - Explorer Explorer Program Explorer Program Browse Import Export Edit Browse Import Export Edit X New Region Directory New Region Directory Facilty Facilty New Exam Directory New Exam Directory Ne Create a new exam inside the selected Ne Create a new exam inside the selected region region Brain routine SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 Master Template Effective Date: 10 Aug 2021 | HILS 2224 Healthineers Job Aid Effective Date: 09 Jul 2022 | HOOD05162003288722 Job Aid | Create a Dot Engine/myExam Assist Program – Numaris XA50 Effective Date: Jul 9, 2022 | HOOD05162003288722 8. Select the new Exam. 9. Select Organize Directories. 10. Select New Program. 11. Select Program Editor. The Edit window opens. myExam Cockpit - Explorer myExam Cockpit - Program Editor (New Program) Explorer Pr Browse Import Export Explorer Program Editor Browse Import Export Edit Simulate Facilty New Region Directory X New Exam Directory New Program Create a new program Brain routine 12. To add a New Strategy, select Sidebar > Strategy. 13. Drag and drop Strategy from the sidebar into the Measurement Program. myExam Cockpit - Program Editor (New Program) Explorer Program Editor Browse Import Export Edit Simulate >> Standard Browse Search Default myExam Autopilot SIEMENS Patient View Basic Patient View Strategy head [ Brain Assist program clinical libraries genera El lesion E trauma Select a Program or Library Strategy Decision Interaction Pause SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 Master Template Effective Date 10 Aug 2021 | HILS 2224 Healthineers Page 2 of 8 Job Aid | Create a Dot Engine/myExam Assist Program – Numaris XA50 Effective Date: Jul 9, 2022 | HOOD05162003288722 14. To change the Strategy name, select F2 – rename the Strategy. 15. Select Enter. myExam Cockpit - Program Editor (New Program) Explorer Program Editor Browse Import Export Edit Simulate Patient View 4 Basic Patient View V Standard 16. Add a Program Step by selecting Sidebar > Browser. 17.Navigate to the Siemens tree and select Exam > Study > Program > Program Steps. 18. Drage and drop Program Steps from the sidebar into the Measurement Program. Note: Continue to add additional program steps from other trees, studies, exams or program areas until all program steps have been incorporated. myExam Cockpit - Program Editor (New Program) Explorer Program Editor Browse Import Export Edit Simulate X ... Standard Browse Search Default myExam Autopilot SIEMENS Brain Assist Neuro Patient View V y a t1 Standard AAhead_scout 00:14 [ GOBrain [6] AutoAlign Scout library [75] t1_qtse_dark-fluid_sag_p2 04:38 El localizer Generic Views t2_qtse_tra_p3 01:08 E| T1 [42] Generic Views E T2 t2_qtse_dark-fluid_tra 04:14 E PD+T2 Generic Views E 30 [12] ep2d_diff_3scan_trace_p2 01:42 Generic Views t1_tse_fs_tra_3mm 03:54 t1_f12d_tra 01:19 t1_tse_tra_3mm 04:58 1 Generic Views t1_tse_r_tra_p2 03:56 t1_tse_r_tra_2mm 03:53 t1_tse_r_tra_p2 03:56 coronal t1_12d_cor 01:19 Strategy Decision Interaction Pause SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 Master Template Effective Date 10 Aug 2021 | HILS 2224 Healthineers Page 3 of 8 Job Aid | Create a Dot Engine/myExam Assist Program – Numaris XA50 Effective Date: Jul 9, 2022 | HOOD05162003288722 19. Add a Decision by selecting Sidebar > Decision. 20. Drag and drop Decision from the sidebar into the Measurement Program. myExam Cockpit - Program Editor (New Program) Explorer Program Editor Browse Import Export Edit Simulate > Standard Browse Search Default myExam Autopilot SIEMENS Brain Assist Neuro Patient View x V Standard AAhead_scout 00:14 GOBrain [6] AutoAlign Scout [ library [75] t1_qtse_dark-fluid_sag_p2 04:38 Generic Views El localizer t2_qtse_tra_p3 01:08 E T1 [42] O Generic Views E T2 t2_qtse_dark-fluid_tra 04:14 El POLT2 Generic Views t1_tse_fs_tra_3mm 03:54 ep2d_diff_3scan_trace_p2 01:42 1 O Generic Views t1_tse_tra_3mm 04:58 t1_f12d_tra 01:19 1 Generic Views t1 tse r tra 2mm 03:53 t1_tse_r_tra_p2 03:56 t1_tse_r_tra_p2 03:56 Decision Drag to create a decision. The decision shows up in the Patient View unless you yes no assign a decision step. Strategy Decision Interaction Pause 21. To change Decision name, select F2 – rename Decision > select Enter. myExam Cockpit - Program Editor (New Program) Explorer Program Browse Import Export Edit Brain Assist 4 Neuro Patient View V Standard AAhead_scout 00:14 AutoAlign Scout t1_qtse_dark-fluid_sag_p2 04:38 Generic Views t2_qtse_tra_p3 01:08 Generic Views t2_qtse_dark-fluid_tra 04:14 21 O Generic Views ep2d_diff_3scan_trace_p2 01:42 1 Generic Views t1_f12d_tra 01:19 Generic Views t1_tse_r_tra_p2 03:56 Decision With contrast Without contrast SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 Master Template Effective Date 10 Aug 2021 | HILS 2224 Healthineers Page 4 of 8 Job Aid | Create a Dot Engine/myExam Assist Program – Numaris XA50 Effective Date: Jul 9, 2022 | HOOD05162003288722 22. To add a Pause, select Sidebar > Pause. 23. Drag and drop the Pause from the sidebar into the Measurement Program. myExam Cockpit - Program Editor (New Program ? 0 x Explorer Program Editor Browse Import Export Edit Simulate >> Standard Browse Search Default myExam Autopilot SIEMENS Brain Assist Neuro Patient View Standard AAhead_scout 00:14 GOBrain [6] O AutoAlign Scout [library [75] t1_qtse_dark-fluid_sag_p2 04:38 El localizer O Generic Views t2_qtse_tra_p3 E T1 [42] Generic Views E T2 t2_qtse_dark-fluid_tra 04:14 21 Generic Views t1_tse_fs_tra_3mm 03:54 O ep2d_diff_3scan_trace_p2 01:42 Generic Views 04:58 1 O t1_tse tra_3mm t1_f12d_tra Generic Views t1_tse_r_tra_2mm 03:53 t1_tse_r_tra_p2 03:56 t1_tse_r_tra_p2 03:56 Decision carnal With contrast Pause Strategy Drag to create a pause. Interaction Pause 24. To add Contrast Agent Admission and change Name of Pause, right click on Pause > select Edit Properties. 25. In the Name field type Contrast Agent Injection. 26. Enter a description in the Description field (optional). 27. Ensure the Contrast agent admission check box has been selected. 28. Select OK. >> Inject contrast ? X General Name Inject contrast Description Contrast agent admission Agent Name Magnevist Catalog ... Active Ingredient Dilution Concentration Open Injector Control OK Cancel SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 Master Template Effective Date 10 Aug 2021 | HILS 2224 Healthineers Page 5 of 8 Job Aid | Create a Dot Engine/myExam Assist Program – Numaris XA50 Effective Date: Jul 9, 2022 | HOOD05162003288722 29. To add a Post Contrast Program step, press the Ctrl key > left click on Post Contrast Program step and drag and drop below the Contrast Agent Injection comment. -OR- Browse > select Program Step from a tree (Siemens or Customer) > drag and drop below Contrast Agent Injection comment. 30. Rename Program Step to Post_T1xxxx program step. Hint: Select F2 > modify Program Step name. myExam Cockpit - Program Editor (New Program) Explorer Program Editor Browse Import Export Edit Simulate X rain Assist Neuro Patient View Standard AAhead scout 00:14 AutoAlign Scout t1_qtse_dark-fluid_sag_p2 04:38 Generic Views t2_qtse_tra_p3 01:08 Generic Views t2_qtse_dark-fluid_tra 04:14 Generic Views ep2d_diff_3scan_trace_p2 1 Generic Views t1_f12d_tra 01:19 Generic Views t1_tse_r_tra_p2 03:56 Decision With contrast Inject contrast Post t1_tse_r_tra_p2 03:56 Post t1_mp2rage_sag_p3_iso 05:59 31. Copy Reference (for example Copy Parameters), by selecting Two Measurement steps in the program. 32. Select the Create CopyRef symbol. myExam Cockpit - Program Editor (New Program) myExam Cockpit - Program Editor (New Program) Explorer Program Editor Explorer Program Editor Browse Import Export Edit Simulate Browse Import Export Edit Simulate X D Standard Create CopyRef X Brain Assist Neuro Patient View Brain Assist Neuro Pa Create CopyRef V Standard V Standard SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 Master Template Effective Date 10 Aug 2021 | HILS 2224 Healthineers Page 6 of 8 Job Aid | Create a Dot Engine/myExam Assist Program – Numaris XA50 Effective Date: Jul 9, 2022 | HOOD05162003288722 33. In the Step Properties window, Copy reference is active (for example default box is checked). 34. Source Protocol step is displayed. 35. Copy Parameter Group, select the Parameter Settings that apply from the Source to Target program step. Brain Assist Neuro Patient View >> Post t1_tse_r_tra_p2 X General Standar Protocol Parameters Copy reference is active AAhead_scout 00:14 Voice Commands AutoAlign Scout Source protocol step |t1_tse__tra_p2 t1_qtse_dark-fluid_sag_p2 Execution 04:38 Image Management copy parameter group Center of slice groups and saturation regions O Generic Views t2_qtse_tra_p3 01:08 Auto Load Slices and saturation regions Slices and Adjustment volume Generic Views Copy References Slices t2_qtse_dark-fluid_tra 04:14 Saturation regions 1 Generic Views Measurement parameters ep2d_diff_3scan_trace_p2 01:42 Adjustment volume 1 Generic Views Table position t1_f12d tra 01:19 Navigators 1 Generic Views Everything t1_tse_r_tra_p2 03:56 Copy phase encoding direction Decision Steps With contrast Ignore measurements Inject contrast Ignore last step Post t1_tse_r_tra_p2 03:56 Post t1_mp2rage_sag_p3_iso 05:59 OK Cancel P 1 Identical CI 36. Select OK. 37. Repeat until all Copy References have been created for the program. Note: Copy Reference symbols are displayed under program steps in the measurement queue. t1_tse_r_tra_p2 03:56 2 Decision With contrast Inject contrast Post t1 tse r tra_p2 13:56 2 38. Select Save Program. ×

  • cockpit
  • myExam
  • cockpit
  • program editor
  • editor dot cockpit
  • editor dot
  • edit cockpit
  • edit program