Siemens Healthineers Academy

Corindus Robotic PCI - Introduction to CorPath GRX Online Training

This online training provides an interactive general overview of the CorPath® GRX operation, standard features and options that are available on the system.

Target group:​ All users​
Audio:​Yes
Recommended to be viewed on the following devices:​ Laptop, desktop computer (sufficiently large display required)​

backgroundpolitico.png Continue Button Introduction to CorPath GRX Introduction to CorPath® GRX In this online training, we will introduce the most important components of the CorPath® GRX and explain the basic operations of the system. 1 2 3 4 Identify system components Understand basic features Operate control console Verify compatible wires, catheters and devices Welcome: Introduction to CorPath® GRX Welcome to the introduction to Core Path G-R-X, online training module. In this online training, we will introduce the most important components of the Core Path G-R-X and explain the basic operations of the system. At the conclusion of this module, you will be able to identify the system components, understand basic features, operate the control console, and verify compativle wires, catheters and devices. Press next to continue. INTERVENTIONAL COCKPIT Precise robotic control of Guide catheter Guidewire Rapid exchange catheter Radiation-shielded workstation 4K resolution monitor BEDSIDE UNIT Optimized bedside unit for radial access Simple setup & in-procedure workflow Devices fixed during intervention Imaging and device agnostic To learn more about the robotic setup in the interventional suite, select the gray markers. Robotics in the Interventional Suite Second-generation robotic system Robotics in the Interventional Suite Robotics in the Interventional Suite. Second-generation robotic system. To learn more about the robotic setup in the interventional suite, select the green markers. And then press next to continue. Bedside Unit Extended Reach Arm & Robotic Drive EXTENDED REACH ARM FINE-TUNE CONTROLS ROBOTIC DRIVE BEDSIDE TOUCHSCREEN Mounts to all commercially available bed rails 1 Bedside Touchscreen provides step-by-step workflow instructions 4 Can be positioned for any access point by sliding on rail or adjusting using button on Robotic Drive 2 Sterile draping for each case 3 To familiarize yourself with the components of the Bedside Unit, select the orange markers. Key Features Bedside Unit Extended Reach Arm & Robotic Drive Bedside Unit............Extended Reach Arm and Robotic Drive. The bedside unit Mounts to all commercially available bedrails and Can be positioned for any access point by sliding on the rail or adjusting using the button on the Robotic Drive Sterile draping is available for each case The Bedside Touchscreen provides step-by-step workflow instructions To familiarize yourself with the components of the bedside unit, select the green markers, and then press next, to continue Single-Use Cassette Easily drive and exchange devices Sterile, disposable component of CorPath GRX (1 per procedure) Simultaneous and independent movement of up to 3 devices Attaches to Robotic Drive To familiarize yourself with the components of the Single-Use Cassette, select the orange markers. ROTATIONAL DRIVE Y-CONNECTOR HOLDER TRACK CLAMP LINEAR DRIVE AUXILIARY TRACK RX DEVICE TRACK EXCHANGE GROOVE GUIDEWIRE HOLDER Y-Connector Drive Gear attaches to Y-Connector to rotate catheters. Key Features 1 2 3 GUIDE SUPPORT TRACK Single-Use Cassette Easily drive and exchange devices The Single-use cassette is a sterile, disposable component of the corpath GRX, which attaches to the robotic drive, and allows for simultaneous and independent movement of up to 3 devices To familiarize yourself with the components of the single-use cassette, select the orange markers then press next, to continue Workflow with CorPath GRX Workflow with CorPath GRX CorPath GRX Compatibility Table with 4 columns and 4 rows CorPath GRX Advance & Retract Rotates Compatibility Guide Catheter ü ü 5-7 Fr Guidewire ü ü 0.014” RX Device ü û Proximal shaft ≤ 2.3 Fr Table with 1 columns and 1 rows CorPath GRX System is recommended for use with the Abbott Vascular COPILOT® Bleedback Control Valve (Y-Connector) CorPath GRX Compatibility CorPath GRX Compatibility The CorPath GRX is compatible with 5 to 7 french guide catheters oh 1 4 guidewires and RX devices with a proximal shaft less than or equal to 2.3 french. The CorPath GRX system is recommended for use with Abbott Vascular Copilot bleedback control valve y-connectors. Press next to continue. Interventional Cockpit Ergonomic seating position 1 Easily positioned in room 4 Control Console can be moved into Control Room if desired 5 Can be sterile draped if preferred 3 Houses the Control Console, Power Vision Monitor & Foot Switch LEAD SHIELDED COCKPIT (Optional) CONTROL CONSOLE POWER VISION MONITOR 2 To familiarize yourself with the components of the Interventional Cockpit, select the orange markers. Key Features Interventional Cockpit The interventional cockpit is led-lined to protect from radiation, and offers an ergonomic seating position. It houses the control console, power vision monitor, and foot switch. It can be sterile draped if preferred, and can easily be positioned in the room. The control console can also be moved into the control room if desired. To familiarize yourself with the components of the interventional cockpit, select the orange markers then press next, to continue. Control Console To familiarize yourself with the components of the Control Console, select the color-coded markers. Easy to use joysticks for device manipulation Measure anatomy with sub-mm precision technIQ automated moves can be enabled to assist with different procedure tasks Touchscreen enables discrete 1mm movements & discrete wire rotation Joysticks differentiated by look, feel, size, color and sound RX DEVICE JOYSTICK CATHETER JOYSTICK EMERGENCY STOP GUIDEWIRE JOYSTICK TURBO BUTTON TOUCHSCREEN Key Features 1 2 3 4 5 Control Console The control console has 3 Easy to use joysticks for device manipulation, and the Touchscreen enables discrete 1 millimeter movements & discrete wire rotation. Technique automated movements can be enabled to assist with different procedure tasks, and Measure anatomy with sub-millimeter precision The Joysticks are differentiated by look, feel, size, color and sound To familiarize yourself with the components of the Control Console, select the color-coded markers,and then press next, to continue Course Review Congratulations! You have completed the Introduction to CorPath GRX online training module. Select the objectives listed below to review the material before proceeding to the final assessment. Identify system components Identify system components Understand basic features Understand basic features Operate the control console Operate the control console Verify compatible wires, catheters & devices Verify compatible wires, catheters & devices Course Review Congratulations! You have completed the Introduction to CorPath GRX, online training module. Select the objectives listed below to review the material before proceeding to the final assessment. When you are ready, press next to continue. Basic Features Bedside Unit Mounts to all commercially available bed rails Bedside Touchscreen provides step-by-step workflow instructions Sterile draping for each case Can be positioned for any access point by sliding on rail or adjusting using button on Robotic Drive Single-Use Cassette Sterile, disposable component of CorPath GRX (1 per procedure) Attaches to Robotic Drive Simultaneous and independent movement of up to 3 devices Interventional Cockpit Ergonomic seating position Houses the Control Console, Power Vision Monitor & Foot Switch Can be sterile draped if preferred Easily positioned in room. (Control Console can be moved to Control Room if desired) System Components INTERVENTIONAL COCKPIT Precise robotic control of Guide catheter Guidewire Rapid exchange catheter Radiation-shielded workstation 4K resolution monitor BEDSIDE UNIT Optimized bedside unit for radial access Simple setup & in-procedure workflow Devices fixed during intervention Imaging and device agnostic Control Console RX DEVICE JOYSTICK CATHETER JOYSTICK EMERGENCY STOP GUIDEWIRE JOYSTICK TURBO BUTTON TOUCHSCREEN CorPath GRX Compatibility Table with 1 columns and 1 rows CorPath GRX System is recommended for use with the Abbott Vascular COPILOT® Bleedback Control Valve (Y-Connector) Table with 4 columns and 4 rows CorPath GRX Advance & Retract Rotates Compatibility Guide Catheter ü ü 5-7 Fr Guidewire ü ü 0.014” RX Device ü û Proximal shaft ≤ 2.3 Fr Disclaimer Please note that the learning material is for training purposes only! This material is to be used as training material only and shall by no means substitute the official documentation. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “operator Manual”) issued by Siemens Healthineers, in particular for relevant safety information like warnings and cautions. For service-related-topics, please always use the official product specific documentation concerning service instructions (referred to as Computer-based Documentation or CB-DOC) as your main reference. Please contact your local Siemens Healthineers representative for the most up-to-date CB-DOC for your product. Please note: Some functions shown in this material are optional and might not be part of your system. Certain product, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. This training provides a comprehensive functional overview. Please keep in mind that the availability of certain service functionality presented in this training may depend on the relevant product and your service contract. Therefore, please contact your local Siemens Healthineers representative for more information. The reproduction, transmission or distrubution of this training or its content is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or deign, are reserved. ©Siemens Healthcare GmbH2022 Disclaimer Quiz Assessment This assessment will test your retention of the presented content. A passing score of 80% or higher is required to complete the course. You may repeat the assessment as many times as needed. Start Assessment Select the best answer. Question 1 of 5 What size Guide Catheters are compatible with the CorPath® GRX? 5-7 Fr 6-9 Fr 4-6 Fr Multiple Choice Incorrect Incorrect Incorrect Incorrect Incorrect Correct Select all that apply: Question 2 of 5 The Control Console allows for precise robotic control of: RX Devices Guidewire Guidewire Guide Catheter Guide Catheter Select all the apply Incorrect One or more answers are incorrect. Correct Select the best answer. Question 3 of 5 The Cassette allows for simultaneous and independent movement of up to: 1 Device 2 Devices 3 Devices Multiple Choice Correct Incorrect Incorrect Select the best answer. Question 4 of 5 The green joystick on the Control Console will move the: Catheter Guidewire RX Device Multiple Choice Incorrect Incorrect Incorrect Incorrect Incorrect Correct Select the best answer. RX device track Question 5 of 5 The Y-Connector attaches to the __________ to rotate catheters: Track clamp Drive gear Linear drive Multiple Choice Incorrect Incorrect Incorrect Incorrect Incorrect Correct Incorrect Incorrect Assessment Results YOUR SCORE: PASSING SCORE: Retry Retry Continue Continue Continue %Results.ScorePercent%% %Results.PassPercent%% Assessment Results You did not pass the course. Take time to review the assessment then select Retry to continue. Congratulations. You passed the course.. Exit To access your Certificate of Completion, select the Launch button drop down on the course overview page. You can also access the certificate from your PEPconnect transcript. You have completed the Introduction to CorPath® GRX Online Training. Completion Question Bank 1 HOOD05162003305464 I Effective Date: 26 Sep 2022 1.1 Welcome: Introduction to CorPath® GRX 1.2 Robotics in the Interventional Suite 1.3 Bedside Unit Extended Reach Arm & Robotic Drive 1.4 Single-Use Cassette Easily drive and exchange devices 1.5 Workflow with CorPath GRX 1.6 CorPath GRX Compatibility 1.7 Interventional Cockpit Procedural Control 1.8 Control Console 1.9 Course Review 1.10 Disclaimer 2 Final Assessment 2.8 Completion

  • Robotics
  • PCI
  • Percutaneous Coronary Intervention
  • Radiation Safety