Cleaning the Sample Probe and Drain on the Dimension® Family of Integrated Chemistry Systems Video
This video provides instructions on how to clean the sample probe and sample drain on the Dimension® Family of Integrated Chemistry Systems.
The following tools and supplies are. Needed to clean the sample. Probe and sample drain. Undiluted bleach and a sample. Cup to clean the sample probe. 10% bleach solution and a drain brush. To clean the sample. Drain. With the system in. Standby. Select F4. System prep. F6. System counters raise the IMT and reagent lids. In the position field of the sample. Probe. Line. Enter the segment and cup. Position where the 1.5. Milliliter Sample cup is placed. Select enter place the 1.5. Milliliter sample cup of. Undiluted. Bleach. In an adapter in the. Chosen segment position. Select F4. Clean probe to begin the probe cleaning. The. Sample probe moves over the drain. Then to the designated sample cups position. Wait until the sample probe stops. Then select enter. The prompt manually. Clean sample. Probe drain displays. Dip the drain brush into a 10% bleach solution. The. Sample. Drain has two holes. Insert the drain brush into the hole closest to the reagent tray and scrub inside the. Drain. Dip the brush into the bleach solution and scrub the. Drain 3. More times. Use laboratory safe biohazard waste disposal. Procedures when discarding this brush. Remove the sample cup from the segment. Then press any key to continue. Close the instrument lids. Select reset. If documenting using the. Paper. Logs from the dimension system operators. Guide. Document the maintenance in the weekly. Slash monthly maintenance log sheet or instrument log sheet. Or if documenting, using the electronic logs. In the dimension. System software. Document the maintenance in the instrument. Log screen.
1408 20000 235 12000 48000 36000 1409 23 12800 1410 Cleaning the Sample Probe and Drain on the Dimension® Family of Integrated Chemistry Systems SIEMENS . Standby Sampler Idle IMT OK 09/14/22 21:23 Dimension Exit labmanager Enter en OPERATING MENU STAT Status PLEASE SELECT AN OPTION USING THE FUNCTION KEYS: Sample Alert At any time, press HELP to get help, or press EXIT to exit a program. Supplies QC Alert Calib Alert To Shut down or Change Operator, press Sign Out or Alt+EXIT. Run Home F1: ENTER DATA F2: SAMPLE STATUS F3: TEST RESULTS F4: SYSTEM CHECK F5: PROCESS CTRL F6: SYSTEM CONFIG F7: DIAGNOSTICS F8: SEGMENT STATUS Healthineers 01/12/23 07:43 SYSTEM PREPARATION MENU F1: INVENTORY F2: REAGENT PREP F3: IMT F5: TEMP MONITOR F6: SYS COUNTERS F7: PUMP PRIME F8: DAILY MAINT. Dimension EXL 20 Dim Dimension EXL 200 SIEMENS 03/23/23 01:16 SYSTEM COUNTERS Installed: 5-AUG-2020 Bootups: 13 Cuvettes: 235 Tests: Dirty windows: Item Cycles Clean at Last Cleaned Sample Probe: 22-MAR-2023 21:29 Pos: D1 Cycles Replace at Last Replaced Replace Cuvette Cartridge: 5-AUG-2020 11:29 NO Diaphragm: Sample Probe Tip: R1 Probe Tip: F1: STORE CHANGES F2: DIAPH CHANGE F3: FILM LOAD F4: CLEAN PROBE F5: F6: HM COUNTERS F7: RMS COUNTERS F8: Pos: D1 22-MAR-2023 21:29 Cycles Replace at Delete Help Alarm PgUp PgDn F8 03/23/23 01:53 ABCDEF System Prep Cleaning sample probe ... Press any key to cancel. Re IMT Port Theel 03/23/23 03:11 aph Wait until the sample probe stops ... Then press (Enter). 23-MAR-2023 3:11 Pos: D1 03/23/23 03:13 R2 Probe Tip: Manually clean the sample probe drain, Then press (Enter) to continue. Rea 03/23/23 20:47 23-MAR-2023 20:46 Pos: D1 Remove cup from Segment D position 1, then press any key. Dimen FERR F1 F2 F4 F7 PHOS - Backspace Tab Caps Lock FPSA MAINTENANCE LOGS Year: 20Xx Operator Disclaimer Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. C Siemens Healthcare GmbH 2023
- dimension
- dimension family
- probe drain
- sample probe
- maintenance