
Cleaning the Primary Waste Reservoir on the Atellica® IM Analyzer Job Aid Version 1.26 and Above
This job aid provides instructions on how to perform the as needed maintenance task of cleaning the primary waste reservoir on the Atellica® IM Analyzer.
Cleaning the Primary Waste Reservoir on the Atellica® IM Analyzer SIEMENS Job Aid Healthineers Cleaning the IM Primary Waste Reservoir All Activities ? = X The operator must clean the IM primary waste reservoir as Filters Tx Clear Module : IM-01 Activity Type: All Frequency : All needed to ensure it is free from dirt or liquids. 3 Module Module Activity Last Completed IM-01 Activity Type IM-01 IM Weekly Maintenance Inprocess (4 minutes remaing) View Details To clean the IM Primary Waste Reservoir: All IM-01 4 5 Cleaning the IM Primary Waste Reservoir May 9, 2021 Perform Frequenc 1. Ensure the analyzer is in Ready or Standby state All Mark as Completed IM-01 Cleaning the Reagent Drawer March 17, 2021 Q Search Activity Procedure Details A. From the System Status map, select the IM module IM-01 Replacing the Sample Probe May 9, 2021 IM-01 IM Daily Maintenance May 9, 2021 B. Review the status of the IM analyzer IM-01 IM Autocheck May 9, 2021 IM-01 IM Weekly Maintenance 2. Select Maintenance > All Activities May 3, 2021 3. From the Filters Module drop-down menu, select the IM Analyzer module 4. Select Cleaning the IM Primary Waste Reservoir 5. Select Perform > Yes 6. Wait for maintenance to complete Close Template Effective Date: 27-MAY-2019 | HOOD05162003010284 1 Effective Date: 28-JUL-2021 | HOOD05162003208944 Unrestricted © Siemens Healthineers, 2021 SIEMENS Healthineers Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Atellica, and all associated marks are trademarks of Siemens Healthcare Diagnostics Inc. or its affiliates. All other trademarks and brands are the property of their respective owners. Product availability varies by country and is subject to varying regulatory requirements. Please contact your local representative for availability. Copyright © Siemens Healthcare GmbH 2021 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 2 siemens-healthineers.com Effective Date: 28-JUL-2021 | HOOD05162003208944 Unrestricted © Siemens Healthineers, 2021
- attelica
- attellica
- atelica