Cleaning the Primary Waste Reservoir on the Atellica® IM Analyzer Job Aid Version 1.25 and Below

This job aid provides instructions on how to perform the as needed maintenance task of cleaning the reagent drawer on the Atellica® IM Analyzer.

Atellica® IM Analyzer SIEMENS Cleaning the Primary Waste Reservoir Job Aid Healthineers The operator must clean the IM primary waste reservoir as SIEMENS Healthineers Atellica® Solution Version 1.15.0.3080004 2 P-P1-04 needed to ensure it is free from dirt or liquids. 3 System Samples Inventory Calibration Qc Patient Orders Worklist Maintenance Setup Schedule Report Log IMT Data Restore Software Updates Copy Configuration To clean the IM Primary Waste Reservoir: Filter Module: P1-02 Frequency: As Needed Time: All Performed By: All 5 Module P1-02 Module Ensure the analyzer is in ready or standby state Activity Scheduled Sun-30 Mon-01 Tue-02 Wed-03 Thu-04 Fri-05 Sat-0 Perform 1. Frequency As Needed 4 Cleaning the Cuvette Waste Area My As Needed Mark as Completed 2. On the Command bar, select Maintenance Time All P1-02 I-P1-02 Cleaning the IM Primary Waste Reservoir My As Needed Not Perform. Performed By All i- P1 -02 Cleaning the Reagent Drawer Thy As Needed Procedure Details EDO 3. Select the Schedule tab Search Text Enter the activity name P1-02 I-P1-02 Cleaning the Reagent Probe Rinse Stations My As Needed -- Scheduled by Operator P1-02 Edit/View ... Cleaning the Sample Tip Waste Area Why As Needed 4. Select Cleaning the IM Primary Waste Reservoir Scheduled Automatically P1-02 i-P1-02 Cleaning the System Fluids Drawer My As Needed -- Delete -- Scheduled by Service P1-02 Select Perform… Cleaning the Waste Probe and the Cuvette Ejector Rod hy As Needed -- -- -- 5. Failed Overdue 6. Select Yes Inprocess v Completed 7. Wait approximately 10 minutes for maintenance to X Not Performed With Comments complete View Activities Add Activity ... Set Warning .. ? PEP LabManager Wednesday, October 03, 2018 2:15 PM 1 Effective Date: 20-DEC-2020 | HOOD05162003152571 Unrestricted © Siemens Healthineers, 2020 SIEMENS Healthineers Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Atellica, and all associated marks are trademarks of Siemens Healthcare Diagnostics Inc. or its affiliates. All other trademarks and brands are the property of their respective owners. Product availability varies by country and is subject to varying regulatory requirements. Please contact your local representative for availability. Copyright © Siemens Healthcare GmbH 2020 Global Siemens Healthineers Headquarters Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84 0 siemens.com/healthineers 2 Effective Date: 20-DEC-2020 | HOOD05162003152571 Unrestricted © Siemens Healthineers, 2020

  • attelica
  • attellica
  • atelica