Siemens Healthineers Academy

Cleaning and disinfection

This PDF provides step-by-step instructions for the proper disinfection and cleaning of the LUMINOS Q.namix R system. It includes recommended cleaning agents, safety precautions, and procedures to ensure hygienic and safe operation.

Target group: All users
Audio: No
Recommended to be viewed on the following devices: All (incl. tablet, smartphone)

SIEMENS Healthineers Cleaning and disinfection for LUMINOS Q.namix R Template Effective Date: 26 Mar 2025 | QR700020784 1 Job Aid Effective Date: 02 Jun 2025 | QR7000021145 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 Cleaning and disinfection for LUMINOS Q.namix R - SIEMENS Healthineers Table of contents Cleaning and disinfection workflow 3 Active ingredient classes 4 Accessories 5 Template Effective Date: 26 Mar 2025 | QR700020784 2 Job Aid Effective Date: 02 Jun 2025 | QR7000021145 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 Disinfection & cleaning workflow SIEMENS Healthineers Cleaning Disinfecting 1. Thoroughly wipe all surfaces with sufficiently saturated cleaning 1. Thoroughly wipe all surfaces with sufficiently saturated disinfection wipes. wipes. 2. Ensure that all surfaces, crevices, and notches are accessible during 2. Ensure that all surfaces, crevices, and notches are accessible during the cleaning process and are completely moistened. the disinfection process and are completely moistened. 3. Check all parts and surfaces for cleanliness. If soiling is still visible, 3. Ensure that all surfaces remain exposed to the disinfectant for the repeat the cleaning steps above. exposure time required by the disinfectant manufacturer. 4. To remove cleaner residue, moisten wipes with sufficient water and 4. Remove disinfectant residue with damp wipes moistened with wipe down the cleaned surfaces. sufficient water. 5. Let all surfaces dry completely before use. Cleaning the DAP chamber: • Use a soft cloth to avoid scratching Cleaning the MAX and X.wi-D detectors: The charge contact plate on the back of the detector must be completely dry before you return the detector to the docking station, the table bucky tray or the bucky wall stand. Otherwise, the detector will not charge sufficiently, and the charge contact surfaces may corrode. Clean the back of the detector first so that it has more time to dry while you clean the front. Template Effective Date: 26 Mar 2025 | QR700020784 3 Job Aid Effective Date: 02 Jun 2025 | QR7000021145 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 Active ingredient classes SIEMENS Healthineers Carefully read chapter 2.4 ‘Cleaning and disinfection’ in the Operator Manual of the LUMINOS Q.namix R. You can use the following active ingredient classes: • pH-neutral cleaning products • Quaternary compounds • Guanidine derivatives • Pyridine derivatives • Alkylamines • Organic acids Example products (permitted) • Peroxide compounds Do not use the following active ingredient classes: Disinfectant wipes: • ECOLAB Incidin OxyWipe S • Surgical spirit • Alcohol solutions Disinfectant cleaners: • Phenol derivatives • Hypochlorites • ECOLAB Incidin OxyFoam S • Accelerated hydrogen peroxides • ECOLAB Incidin Active • BODE Chemie Dismozon Plus The safety data sheets of the manufacturer provide detailed information on the composition of the disinfectants. Template Effective Date: 26 Mar 2025 | QR700020784 4 Job Aid Effective Date: 02 Jun 2025 | QR7000021145 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 Accessories SIEMENS Healthineers Please note that for some accessory parts, there are special cleaning instructions in the corresponding chapters. Refer to the chapter ‘Register Accessories and Auxiliary Devices’ in the operator manual. If there are no special instructions, the manual cleaning and disinfection instructions apply. Template Effective Date: 26 Mar 2025 | QR700020784 5 Job Aid Effective Date: 02 Jun 2025 | QR7000021145 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 SIEMENS Healthineers Please note that this learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product-related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration-dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Siemens Healthineers Headquarters Siemens Healthineers AG Siemensstr. 3 91301 Forchheim, Germany Phone: +49 9191 180 siemens-healthineers.com Template Effective Date: 26 Mar 2025 | QR700020784 6 Job Aid Effective Date: 02 Jun 2025 | QR7000021145 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025

  • Luminos
  • qnamix
  • q.namix
  • R
  • clean
  • disinfect